11 research outputs found

    Validity and reliability of a novel 3D scanner for assessment of the shape and volume of amputees’ residual limb models

    Get PDF
    Objective assessment methods to monitor residual limb volume following lower-limb amputation are required to enhance practitioner-led prosthetic fitting. Computer aided systems, including 3D scanners, present numerous advantages and the recent Artec Eva scanner, based on laser free technology, could potentially be an effective solution for monitoring residual limb volumes. The aim of this study was to assess the validity and reliability of the Artec Eva scanner (practical measurement) against a high precision laser 3D scanner (criterion measurement) for the determination of residual limb model shape and volume. Three observers completed three repeat assessments of ten residual limb models, using both the scanners. Validity of the Artec Eva scanner was assessed (mean percentage error <2%) and Bland-Altman statistics were adopted to assess the agreement between the two scanners. Intra and inter-rater reliability (repeatability coefficient <5%) of the Artec Eva scanner was calculated for measuring indices of residual limb model volume and shape (i.e. residual limb cross sectional areas and perimeters). Residual limb model volumes ranged from 885 to 4399 ml. Mean percentage error of the Artec Eva scanner (validity) was 1.4% of the criterion volumes. Correlation coefficients between the Artec Eva and the Romer determined variables were higher than 0.9. Volume intra-rater and inter-rater reliability coefficients were 0.5% and 0.7%, respectively. Shape percentage maximal error was 2% at the distal end of the residual limb, with intra-rater reliability coefficients presenting the lowest errors (0.2%), both for cross sectional areas and perimeters of the residual limb models. The Artec Eva scanner is a valid and reliable method for assessing residual limb model shapes and volumes. While the method needs to be tested on human residual limbs and the results compared with the current system used in clinical practice, it has the potential to quantify shape and volume fluctuations with greater resolution

    Generation of subject-specific, dynamic, multisegment ankle and foot models to improve orthotic design: a feasibility study

    Get PDF
    ABSTRACT: BACKGROUND: Currently, custom foot and ankle orthosis prescription and design tend to be based on traditional techniques, which can result in devices which vary greatly between clinicians and repeat prescription. The use of computational models of the foot may give further insight in the biomechanical effects of these devices and allow a more standardised approach to be taken to their design, however due to the complexity of the foot the models must be highly detailed and dynamic. METHODS: Functional and anatomical datasets will be collected in a multicentre study from 10 healthy participants and 15 patients requiring orthotic devices. The patient group will include individuals with metarsalgia, flexible flat foot and drop foot. Each participant will undergo a clinical foot function assessment, 3D surface scans of the foot under different loading conditions, and detailed gait analysis including kinematic, kinetic, muscle activity and plantar pressure measurements in both barefoot and shod conditions. Following this each participant will undergo computed tomography (CT) imaging of their foot and ankle under a range of loads and positions while plantar pressures are recorded. A further subgroup of participants will undergo magnetic resonance imaging (MRI) of the foot and ankle. Imaging data will be segmented to derive the size of bones and orientation of the joint axes. Insertion points of muscles and ligaments will be determined from the MRI and CT-scans and soft tissue material properties computed from the loaded CT data in combination with the plantar pressure measurements. Gait analysis data will be used to drive the models and in combination with the 3D surface scans for scaling purposes. Predicted plantar pressures and muscle activation patterns predicted from the models will be compared to determine the validity of the models. DISCUSSION: This protocol will lead to the generation of unique datasets which will be used to develop linked inverse dynamic and forward dynamic biomechanical foot models. These models may be beneficial in predicting the effect of and thus improving the efficacy of orthotic devices for the foot and ankle

    Inter- and intra-observer reproducibility and validity of an indirect volume measurement in transtibial amputees.

    No full text
    Item does not contain fulltextThe objective of the study was to assess the measurement properties of an indirect volumetric measurement using segmental circumferential measurements fitted into a formula of a truncated cone (Sitzia's method) in long-term transtibial amputees. Twenty-eight participants with a transtibial amputation >1 year participated in the study. Two observers measured stump volume twice, two weeks apart, using both Sitzia's method and the water displacement volumetric method (criterion standard test). The mean differences and upper and lower limits of agreement between the water displacement volumetric method and Sitzia's method, between the first and second assessment, and between both assessors were calculated. Intra-class correlation coefficients (ICCs) were derived from random-effects two-way analysis of variance. Inter-observer agreements of both methods were high and ranged from 86-96%. Intra-observer agreement ranged between 57% and 71%. In both methods the inter- and intra-observer differences were not significant. ICCs ranged from 0.88-0.99 and were better for inter-observer compared to intra-observer reproducibility. Lower stump volumes were observed in Sitzia's method compared to water displacement volumetric method, with high ICC's (0.92-0.95) between both methods. Although Sitzia's method systematically underestimates stump volume, it is a reliable and feasible alternative to the criterion standard test. To determine its validity to detect (longitudinal) differences in stump volume, follow-up research is needed in participants with recent amputations.1 maart 201

    Tarsal and Metatarsal Bone Mineral Density Measurement Using Volumetric Quantitative Computed Tomography

    No full text
    A new method for measuring bone mineral density (BMD) of the tarsal and metatarsals is described using volumetric quantitative computed tomography (VQCT) in subjects with diabetes mellitus and peripheral neuropathy. VQCT images of a single foot were acquired twice from eight subjects (mean age 51 [11 SD], seven males, one female). The cortical shells of the seven tarsal and five metatarsal bones were identified and semiautomatically segmented from adjacent bones. Volume and BMD of each bone were measured separately from the two acquired scans for each subject. Whole-bone semiautomatic segmentation measurement errors were determined as the root mean square coefficient of variation for the volume and BMD of 0.8% and 0.9%, respectively. In addition to the whole-bone segmentation methods, we performed atlas-based partitioning of subregions within the second metatarsal for all subjects, from which the volumes and BMDs were obtained for each subregion. The subregion measurement BMD errors (root mean square coefficient of variation) within the shaft, proximal end, and distal end were shown to vary by approximately 1% between the two scans of each subject. The new methods demonstrated large variations in BMDs between the 12 bones of the foot within a subject and between subjects, and between subregions within the second metatarsal. These methods can provide an important outcome measure for clinical research trials investigating the effects of interventions, aging, or disease progression on bone loss, or gain, in individual foot bones