4,400 research outputs found

    Virtual edge illumination and one dimensional beam tracking for absorption, refraction, and scattering retrieval

    Get PDF
    We propose two different approaches to retrieve x-ray absorption, refraction, and scattering signals using a one dimensional scan and a high resolution detector. The first method can be easily implemented in existing procedures developed for edge illumination to retrieve absorption and refraction signals, giving comparable image quality while reducing exposure time and delivered dose. The second method tracks the variations of the beam intensity profile on the detector through a multi-Gaussian interpolation, allowing the additional retrieval of the scattering signal

    X–ray absorption, phase and dark–field tomography through a beam tracking approach

    Get PDF
    We present a development of the beam–tracking approach that allows its implementation in computed tomography. One absorbing mask placed before the sample and a high resolution detector are used to track variations in the beam intensity distribution caused by the sample. Absorption, refraction, and dark–field are retrieved through a multi–Gaussian interpolation of the beam. Standard filtered back projection is used to reconstruct three dimensional maps of the real and imaginary part of the refractive index, and of the dark–field signal. While the method is here demonstrated using synchrotron radiation, its low coherence requirements suggest a possible implementation with laboratory sources

    Laboratory-based edge-illumination phase-contrast imaging: Dark-field retrieval and high-resolution implementations

    Get PDF
    Edge illumination is an X-ray phase-contrast imaging technique capable of quantitative retrieval of phase and amplitude images. The retrieval of the ultra-small-angle X-ray scattering was recently developed and implemented with the area-imaging counterpart of an edge-illumination system, sometimes referred to as coded-aperture setup. This is an incoherent and achromatic technique, well suited for translation of the potential of X-ray phase contrast imaging into efficient laboratory-scale setups. We report on recent advances of these developments along two main directions. One relates to the expansion of the technique with respect to the data analysis and corrections that are required when non-ideal optical elements are used and optimized sampling strategies. The second is directed towards high-resolution and high-energy implementations. A laboratory-based prototype for high-energy X-ray phase-contrast microscopy was built and its performance was modelled and experimentally characterized

    Phase-contrast microscopy at high x-ray energy with a laboratory setup

    Get PDF
    We report on the design and realization of an x-ray imaging system for quantitative phase-contrast microscopy at high x-ray energy with laboratory-scale instrumentation. Phase and amplitudewere separated quantitatively at x-ray energies up to 80 keV with micrometric spatial resolution. The accuracy of the results was tested against numerical simulations, and the spatial resolution was experimentally quantified by measuring a Siemens star phase object. This simple setup should find broad application in those areas of x-ray imaging where high energy and spatial resolution are simultaneously required and in those difficult cases where the sample contains materials with similar x-ray absorption

    A single-image retrieval method for edge illumination X-ray phase-contrast imaging: Application and noise analysis

    Get PDF
    Purpose: Edge illumination (EI) X-ray phase-contrast imaging (XPCI) has been under development at University College London in recent years, and has shown great potential for both laboratory and synchrotron applications. In this work, we propose a new acquisition and processing scheme. Contrary to existing retrieval methods for EI, which require as input two images acquired in different setup configurations, the proposed approach can retrieve an approximate map of the X-ray phase from a single image, thus significantly simplifying the acquisition procedure and reducing data collection times. Methods: The retrieval method is analytically derived, based on the assumption of a quasi-homogeneous object, i.e. an object featuring a constant ratio between refractive index and absorption coefficient. The noise properties of the input and retrieved images are also theoretically analyzed under the developed formalism. The method is applied to experimental synchrotron images of a biological object. Results: The experimental results show that the method can provide high-quality images, where the “edge” signal typical of XPCI images is transformed to an “area” contrast that enables an easier interpretation of the sample geometry. Moreover, the retrieved images confirm that the method is highly stable against noise. Conclusions: We anticipate that the developed approach will become the method of choice for a variety of applications of EI XPCI, thanks to its ability to simplify the acquisition procedure and reduce acquisitions time and dose to the sample. Future work will focus on the adaptation of the method to computed tomography and to polychromatic radiation from X-ray tubes

    Simple and robust synchrotron and laboratory solutions for high-resolution multimodal X-ray phase-based imaging

    Get PDF
    Edge illumination X-ray phase contrast imaging techniques are capable of quantitative retrieval of differential phase, absorption and X-ray scattering. We have recently developed a series of approaches enabling high-resolution implementations, both using synchrotron radiation and laboratory-based set-ups. Three-dimensional reconstruction of absorption, phase and dark-field can be achieved with a simple rotation of the sample. All these approaches share a common trait which consists in the use of an absorber that shapes the radiation field, in order to make the phase modulations introduced by the sample detectable. This enables a well-defined and high-contrast structuring of the radiation field as well as an accurate modelling of the effects that are related to the simultaneous use of a wide range of energies. Moreover, it can also be adapted for use with detectors featuring large pixel sizes, which could be desirable when a high detection efficiency is important

    The effect of intervertebral cartilage on neutral posture and range of motion in the necks of sauropod dinosaurs

    Get PDF
    The necks of sauropod dinosaurs were a key factor in their evolution. The habitual posture and range of motion of these necks has been controversial, and computer-aided studies have argued for an obligatory sub-horizontal pose. However, such studies are compromised by their failure to take into account the important role of intervertebral cartilage. This cartilage takes very different forms in different animals. Mammals and crocodilians have intervertebral discs, while birds have synovial joints in their necks. The form and thickness of cartilage varies significantly even among closely related taxa. We cannot yet tell whether the neck joints of sauropods more closely resembled those of birds or mammals. Inspection of CT scans showed cartilage:bone ratios of 4.5% for Sauroposeidon and about 20% and 15% for two juvenile Apatosaurus individuals. In extant animals, this ratio varied from 2.59% for the rhea to 24% for a juvenile giraffe. It is not yet possible to disentangle ontogenetic and taxonomic signals, but mammal cartilage is generally three times as thick as that of birds. Our most detailed work, on a turkey, yielded a cartilage:bone ratio of 4.56%. Articular cartilage also added 11% to the length of the turkey's zygapophyseal facets. Simple image manipulation suggests that incorporating 4.56% of neck cartilage into an intervertebral joint of a turkey raises neutral posture by 15°. If this were also true of sauropods, the true neutral pose of the neck would be much higher than has been depicted. An additional 11% of zygapophyseal facet length translates to 11% more range of motion at each joint. More precise quantitative results must await detailed modelling. In summary, including cartilage in our models of sauropod necks shows that they were longer, more elevated and more flexible than previously recognised

    How to assess the effectiveness of nasal influenza vaccines? Role and measurement of sIgA in mucosal secretions

    Get PDF
    Secretory IgAs (sIgA) constitute the principal isotype of antibodies present in nasal and mucosal secretions. They are secreted by plasma cells adjacent to the mucosal epithelial cells, the site where infection occurs, and are the main humoral mediator of mucosal immunity. Mucosally delivered vaccines, such as live attenuated influenza vaccine (LAIV), are able to mimic natural infection without causing disease or virus transmission and mainly elicit a local immune response. The measurement of sIgA concentrations in nasal swab/wash and saliva samples is therefore a valuable tool for evaluating their role in the effectiveness of such vaccines. Here, we describe two standardized assays (enzyme-linked immunosorbent assay and microneutralization) available for the quantification of sIgA and discuss the advantages and limitations of their use

    Proximity to Sports Facilities and Sports Participation for Adolescents in Germany

    Get PDF
    Objectives - To assess the relationship between proximity to specific sports facilities and participation in the corresponding sports activities for adolescents in Germany. Methods - A sample of 1,768 adolescents aged 11–17 years old and living in 161 German communities was examined. Distances to the nearest sports facilities were calculated as an indicator of proximity to sports facilities using Geographic Information Systems (GIS). Participation in specific leisure-time sports activities in sports clubs was assessed using a self-report questionnaire and individual-level socio-demographic variables were derived from a parent questionnaire. Community-level socio-demographics as covariates were selected from the INKAR database, in particular from indicators and maps on land development. Logistic regression analyses were conducted to examine associations between proximity to the nearest sports facilities and participation in the corresponding sports activities. Results - The logisitic regression analyses showed that girls residing longer distances from the nearest gym were less likely to engage in indoor sports activities; a significant interaction between distances to gyms and level of urbanization was identified. Decomposition of the interaction term showed that for adolescent girls living in rural areas participation in indoor sports activities was positively associated with gym proximity. Proximity to tennis courts and indoor pools was not associated with participation in tennis or water sports, respectively. Conclusions - Improved proximity to gyms is likely to be more important for female adolescents living in rural areas
    • …
    corecore