7 research outputs found
Pythagoras project: Development of an innovative training package on Indoor Environment Quality
The aim of the Pythagoras project is the development and assessment of Greek national training material in the sector of indoor environmental quality. The need for education in this specific sector is dictated by the significant indoor environment deterioration and associated health hazards, which are caused by low ventilation levels, combined with the use of many modern building materials that aggravate pollutants emissions. Early in the project, a review is undertaken of the international literature and the syllabuses of foreign research and educational institutions active in indoor environment quality issues. At the same time, the requirements of the Greek educational and broader society, related to issues of indoor pollution and health, are determined. A training methodology is consequently developed, with the objective to optimally cover all the parameters associated with the indoor environment quality, for trainees of various disciplines. The training material is produced both in printed (book) and integrated electronic (e-learning) format. Additionally, four seminars are organized covering the respective sections of the training package. The training package is being assessed both by the trainees but also by international experts in the sector of indoor environment quality
Experimental investigation of the air flow and indoor carbon dioxide concentration in classrooms with intermittent natural ventilation
Air flow and the associated indoor carbon dioxide concentrations have been extensively monitored in 62 classrooms of 27 naturally ventilated schools in Athens, Greece. The specific ventilation patterns as well as the associated carbon dioxide concentrations, before, during and after the teaching period are analysed in detail. During the teaching period, only 23% of the measured classrooms presented a flow rate higher than the recommended value of 8 l/p/s while the mean daily fluctuation was close to 40%. About, 52% of the classrooms presented a mean indoor CO2 concentration higher than 1000 ppm. The specific experimental data have been compared against existing ventilation rates and carbon dioxide concentrations using published information from 287 classrooms of 182 naturally ventilated schools and 900 classrooms from 220 mechanically ventilated schools. The relation between the air flow rates and the corresponding indoor carbon dioxide is analysed and then compared to the existing data from naturally and mechanically ventilated schools. It is found that all three data sets present a CO2 concentration equal to 1000 ppm for air flows around 8 l/p/s. Specific adaptive actions to improve the indoor environmental quality have been recorded and the impact of indoor and ambient temperatures as well as of the carbon dioxide concentration on window opening is analysed in detail. A clear relation is found, between the indoor temperature at which the adapting action takes place and the resulting air flow rate. In parallel, a statistically significant relation between window opening and the indoor-outdoor temperature difference has been established. © 2008 Elsevier B.V. All rights reserved
Indoor air quality in fifty residences in Athens
Measurements of indoor air pollutants covering the concentrations of CO2, CO, TVOC's, PM2.5, and PM10 were performed in 50 residences in Athens. In addition the ventilation rate in each dwelling was continuously measured by monitoring CO2 concentration. Apart from carbon monoxide, almost all the remaining pollutants showed high concentrations that exceeded the maximum threshold levels of the relevant standards. The rate of ventilation was found to have a very important impact on the concentration of indoor pollutants. Finally, the impact of tobacco smoking was found to be very important and the concentration of almost all pollutants increased significantly when the rate of smoking increased
Using intelligent clustering techniques to classify the energy performance of school buildings
The present paper deals with the energy performance, energy classification and rating and the global environmental quality of school buildings. A new energy classification technique based on intelligent clustering methodologies is proposed. Energy rating of school buildings provides specific information on their energy consumption and efficiency relative to the other buildings of similar nature and permits a better planning of interventions to improve its energy performance. The overall work reported in the present paper, is carried out in three phases. During the first phase energy consumption data have been collected through energy surveys performed in 320 schools in Greece. In the second phase an innovative energy rating scheme based on fuzzy clustering techniques has been developed, while in the third phase, 10 schools have been selected and detailed measurements of their energy efficiency and performance as well as of the global environmental quality have been performed using a specific experimental protocol. The proposed energy rating method has been applied while the main environmental and energy problems have been identified. The potential for energy and environmental improvements has been assessed. © 2006 Elsevier B.V. All rights reserved
Experimental investigation of the air flow and indoor carbon dioxide concentration in classrooms with intermittent natural ventilation
Δημοσίευση σε επιστημονικό περιοδικόSummarization: Air flow and the associated indoor carbon dioxide concentrations have been extensively monitored in 62 classrooms of 27 naturally ventilated schools in Athens, Greece. The specific ventilation patterns as well as the associated carbon dioxide concentrations, before, during and after the teaching period are analysed in detail. During the teaching period, only 23% of the measured classrooms presented a flow rate higher than the recommended value of 8 l/p/s while the mean daily fluctuation was close to 40%. About, 52% of the classrooms presented a mean indoor CO2 concentration higher than 1000 ppm. The specific experimental data have been compared against existing ventilation rates and carbon dioxide concentrations using published information from 287 classrooms of 182 naturally ventilated schools and 900 classrooms from 220 mechanically ventilated schools. The relation between the air flow rates and the corresponding indoor carbon dioxide is analysed and then compared to the existing data from naturally and mechanically ventilated schools. It is found that all three data sets present a CO2 concentration equal to 1000 ppm for air flows around 8 l/p/s. Specific adaptive actions to improve the indoor environmental quality have been recorded and the impact of indoor and ambient temperatures as well as of the carbon dioxide concentration on window opening is analysed in detail. A clear relation is found, between the indoor temperature at which the adapting action takes place and the resulting air flow rate. In parallel, a statistically significant relation between window opening and the indoor–outdoor temperature difference has been established.Παρουσιάστηκε στο: Energy and Building
Training for the Indoor Environmental Quality
The aim of the specific paper is to present the methodology followed for the development of a training package in the field of indoor environmental quality. The need for education in this specific sector is dictated by the significant indoor environment problem and associated health hazards as these become evident through a series of studies and measurements. A training methodology is developed and the overall training material is structured in thirteen modules covering all the parameters associated with the indoor environment quality, for trainees of various disciplines. The training modules were evaluated through questionnaires distributed in the framework of indoor environmental quality seminarsJRC.I.2-Chemical assessment and testin
Pythagoras project: Development of an innovative training package on indoor environment quality
Summarization: The aim of the Pythagoras project is the development and assessment of greek national training material in the sector of indoor environmental quality. The need for education in this specific sector is dictated by the significant indoor environment deterioration and associated health hazards, which are caused by low ventilation levels, combined with the use of many modern building materials that aggravate pollutants emissions.
Early in the project, a review is undertaken of the international literature and the syllabuses of foreign research and educational institutions active in indoor environment quality issues. At the same time, the requirements of the greek educational and broader society, related to issues of indoor pollution and health, are determined. A training methodology is consequently developed, with the objective to optimally cover all the parameters associated with the indoor environment quality, for trainees of various disciplines.
The training material is produced both in printed (book) and integrated electronic (e-learning) format. Additionally, four seminars are organized covering the respective sections of the training package. The training package is being assessed both by the trainees but also by international experts in the sector of indoor environment quality.Presented on