170 research outputs found

    First-phase ejection fraction by CMR predicts outcomes in aortic stenosis

    Get PDF
    BACKGROUND: First-phase ejection fraction (EF1; the ejection fraction measured during active systole up to the time of maximal aortic flow) measured by transthoracic echocardiography (TTE) is a powerful predictor of outcomes in patients with aortic stenosis. We aimed to assess whether cardiovascular magnetic resonance (CMR) might provide more precise measurements of EF1 than TTE and to examine the correlation of CMR EF1 with measures of fibrosis. METHODS: In 141 patients with at least mild aortic stenosis, we measured CMR EF1 from a short-axis 3D stack and compared its variability with TTE EF1, and its associations with myocardial fibrosis and clinical outcome (aortic valve replacement (AVR) or death). RESULTS: Intra- and inter-observer variation of CMR EF1 (standard deviations of differences within and between observers of 2.3% and 2.5% units respectively) was approximately 50% that of TTE EF1. CMR EF1 was strongly predictive of AVR or death. On multivariable Cox proportional hazards analysis, the hazard ratio for CMR EF1 was 0.93 (95% confidence interval 0.89–0.97, p = 0.001) per % change in EF1 and, apart from aortic valve gradient, CMR EF1 was the only imaging or biochemical measure independently predictive of outcome. Indexed extracellular volume was associated with AVR or death, but not after adjusting for EF1. CONCLUSIONS: EF1 is a simple robust marker of early left ventricular impairment that can be precisely measured by CMR and predicts outcome in aortic stenosis. Its measurement by CMR is more reproducible than that by TTE and may facilitate left ventricular structure–function analysis

    External beam irradiation of myocardial carcinoid metastases: a case report

    Get PDF
    The heart is an exceedingly rare site of metastatic involvement in carcinoid tumors. Only nineteen cases have been described in the literature over the past 30 years. We report here on a patient who presented with progressive carcinoid syndrome despite surgical resection of her liver metastases. She was found to have cardiac metastases on inidium-111-pentetreotide scintigraphy and subsequently underwent external beam radiation to the heart resulting in symptomatic palliation of her syndrome and objective radiographic response. To our knowledge, this is the first reported case of metastatic cardiac carcinoid treated with external beam irradiation

    Imaging myocardial carcinoid with T2-STIR CMR

    Get PDF
    We used T2-STIR (Short Tau Inversion Recovery) cardiovascular magnetic resonance to demonstrate carcinoid tumor metastases to the heart and liver in a 64-year-old woman with a biopsy-proven ileal carcinoid tumor who was referred because of an abnormal echocardiogram

    VEGF attenuates development from cardiac hypertrophy to heart failure after aortic stenosis through mitochondrial mediated apoptosis and cardiomyocyte proliferation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Aortic stenosis (AS) affects 3 percent of persons older than 65 years and leads to greater morbidity and mortality than other cardiac valve diseases. Surgery with aortic valve replacement (AVR) for severe symptomatic AS is currently the only treatment option. Unfortunately, in patients with poor ventricular function, the mortality and long-term outcome is unsatisfied, and only a minority of these patients could bear surgery. Our previous studies demonstrated that vascular endothelial growth factor (VEGF) protects cardiac function in myocardial infarction model through classic VEGF-PI3k-Akt and unclear mitochondrial anti-apoptosis pathways; promoting cardiomyocyte (CM) proliferation as well. The present study was designed to test whether pre-operative treatment with VEGF improves AS-induced cardiac dysfunction, to be better suitable for AVR, and its potential mechanism.</p> <p>Methods</p> <p>Adult male mice were subjected to AS or sham operation. Two weeks later, adenoviral VEGF (Ad-VEGF), enhanced green fluorescence protein (Ad-EGFP, as a parallel control) or saline was injected into left ventricle free wall. Two weeks after delivery, all mice were measured by echocardiography and harvested for further detection.</p> <p>Results</p> <p>AS for four weeks caused cardiac hypertrophy and left ventricular dysfunction. VEGF treatment increased capillary density, protected mitochondrial function, reduced CMs apoptosis, promoted CMs proliferation and eventually preserved cardiac function.</p> <p>Conclusions</p> <p>Our findings indicate that VEGF could repair AS-induced transition from compensatory cardiac hypertrophy to heart failure.</p

    Exercise-induced intra-ventricular gradients as a frequent potential cause of myocardial ischemia in cardiac syndrome X patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The development of intra-ventricular gradients (IVG) during dobutamine or exercise stress is not infrequent, and can be associated to symptoms during stress.</p> <p>The purpose of this study was to assess the occurrence of IVG during exercise stress echocardiography in cardiac syndrome X patients.</p> <p>Methods</p> <p>We prospectively evaluated 91 patients (pts) mean aged 51 ± 12 years (age ranged 20 to 75 years old), 44 of whom were women. All pts had angina, positive exercise ECG treadmill testing, normal rest echocardiogram and no coronary artery disease on coronary angiogram (cardiac X syndrome). After complete Doppler echocardiographic evaluation with determination of left ventricular outflow tract index (LVOTi), relative left ventricular wall thickness (RLVWT) and left ventricular end-diastolic volume index (LVDVi), all patients underwent stress echocardiography with two-dimensional and Doppler echographic evaluation during and after treadmill exercise.</p> <p>Results</p> <p>For analysis purpose patients were divided in 2 groups, according to the development of IVG. Doppler evidence of IVG was found in 33 (36%) of the patients (Group A), with mean age 47 ± 14 years old (age ranged 20 to 72 years) and with a mean end-systolic peak gradient of 86 ± 34 mmHg (ranging from 30 to 165 mmHg). The IVG development was accompanied by SAM of the mitral valve in 23 pts. Three of these pts experienced symptomatic hypotension. Ten were women (30% pts). 58 pts in group B, 34 of whom were women (59%) (p = 0,01 vs group A), mean aged 53,5 ± 10,9 years old (age ranged 34 to 75 years) (p = 0,03 vs group A), did not develop IVG. LVOTi was 10,29 ± 0,9 mm/m<sup>2 </sup>in group A and 11,4 ± 1 mm/m<sup>2 </sup>in group B (p < 0,000); RLVWT was 0,36 ± 0,068 in group A and 0,33 ± 0,046 in group B (p < 0,01); LVDVi was 44,8 ± 10 ml/m<sup>2 </sup>in group A and 56 ± 11,6 ml/m<sup>2 </sup>in group B (p = 0,000).</p> <p>Conclusion</p> <p>1. A significant number of patients with cardiac X syndrome developed IVG during upright exercise in treadmill. These pts (group A) are mainly males and younger than those who did not develop IVG.</p> <p>2. The development of IVG and mitral valve SAM on exertion seems to be associated with ST segment downsloping during stress testing in patients without epicardial coronary disease.</p> <p>3. The development of IVG and mitral valve SAM seems to be associated with lower LVOTi, lower LVDVi and higher RLVWT.</p

    The Scandinavian multicenter hemodynamic evaluation of the SJM Regent aortic valve

    Get PDF
    Background: 112 patients who received small and medium sized St.Jude Regent heart valves (19-25 mm) at 7 Scandinavian centers were studied between January 2003 and February 2005 to obtain non-invasive data regarding the hemodynamic performance at rest and during Dobutamine stress echocardiography (DSE) testing one year after surgery. Material and methods: 46 woman and 66 men, aged 61.8 +/- 9.7 (18-75) years, were operated on for aortic regurgitation (17), stenosis (65), or mixed dysfunction (30). Valve sizes were 19 mm (6), 21 mm (33), 23 mm (41), 25 mm (30). Two patients receiving size 27 valves were excluded from the hemodynamic evaluation. Pledgets were used in 100 patients, everted mattress in 66 and simple interrupted sutures in 21. Valve orientation varied and was dependent on the surgeons' choice. 34 patients (30.4%) underwent concomitant coronary artery surgery. Results: There were two early deaths (1.8%) and three late deaths, one because of pancreatic cancer. Late events during follow-up were: non structural dysfunction (1), bleeding (2), thromboembolism (2). At one year follow up 93% of the patients were in NYHA classes 1-2 versus 47.8% preoperatively. Dobutamine stress echocardiography (DSE) was performed in a total of 66 and maximal peak stress was reached in 61 patients. During DSE testing, the following statistically significant changes took place: Heart rate increased by 73.0%, cardiac output by 85.5%, left ventriclular ejection fraction by 19.6%, and maximal mean prosthetic transvalvular gradient by 133.8%, whereas the effective orifice area index did not change. Left ventricular mass fell during one year from 215 +/- 63 to 197 +/- 62 g (p < 0.05). Conclusion: The Dobutamine test induces a substantial stress, well suitable for echocardiographic assessment of prosthesis valve function and can be performed in the majority of the patients. The changes in pressure gradients add to the hemodynamic characteristics of the various valve sizes. In our patients the St. Jude Regent valve performed satisfactory at rest and under pharmacological stress situation

    Second-opinion stress tele-echocardiography for the Adonhers (Aged donor heart rescue by stress echo) project

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To resolve the current shortage of donor hearts, we established the Adonhers protocol. An upward shift of the donor age cut-off limit (from the present 55 to 65 years) is acceptable if a stress echo screening on the candidate donor heart is normal. This study aimed to verify feasibility of a "second opinion" of digitally transferred images of stress echo results to minimize technical variability in selection of aged donor hearts for heart transplant.</p> <p>Methods</p> <p>The informatics infrastructure was created for a core lab reading with a second opinion from the Pisa stress echo lab. To test the system, simulation standard stress echo cineloops were sent digitally from 5 peripheral labs to the central core lab.</p> <p>Starting January 2009, real marginal donor stress echos were sent via internet to the central core echo lab, Pisa, for a second opinion before heart transplant.</p> <p>Results</p> <p>In the simulation protocol, 30 dipyridamole stress echocardiograms were sent from the five peripheral echo labs to the central core lab in Pisa. Both the echo images and reports were correctly uploaded in the web system and sent to the core echo lab; the second opinion evaluation was obtained in all cases (100% feasibility). In the transplant protocol, eight donor cases were sent to the Pisa core lab for the second opinion protocol, and six of them were transplanted in marginal recipients.</p> <p>Conclusions</p> <p>Second-Opinion Stress Tele-Echocardiography can effectively be performed in a network aimed to safely expand the heart donor pool for heart transplant.</p

    Reduced global longitudinal strain in association to increased left ventricular mass in patients with aortic valve stenosis and normal ejection fraction: a hybrid study combining echocardiography and magnetic resonance imaging

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Increased muscle mass index of the left ventricle (LVMi) is an independent predictor for the development of symptoms in patients with asymptomatic aortic stenosis (AS). While the onset of clinical symptoms and left ventricular systolic dysfunction determines a poor prognosis, the standard echocardiographic evaluation of LV dysfunction, only based on measurements of the LV ejection fraction (EF), may be insufficient for an early assessment of imminent heart failure. Contrary, 2-dimensional speckle tracking (2DS) seems to be superior in detecting subtle changes in myocardial function. The aim of the study was to assess these LV function deteriorations with global longitudinal strain (GLS) analysis and the relations to LVMi in patients with AS and normal EF.</p> <p>Methods</p> <p>50 patients with moderate to severe AS and 31 controls were enrolled. All patients underwent echocardiography, including 2DS imaging. LVMi measures were performed with magnetic resonance imaging in 38 patients with AS and indexed for body surface area.</p> <p>Results</p> <p>The total group of patients with AST showed a GLS of -15,2 ± 3,6% while the control group reached -19,5 ± 2,7% (p < 0,001). By splitting the group with AS in normal, moderate and severe increased LVMi, the GLS was -17,0 ± 2,6%, -13,2 ± 3,8% and -12,4 ± 2,9%, respectively (p = 0,001), where LVMi and GLS showed a significant correlation (r = 0,6, p < 0,001).</p> <p>Conclusions</p> <p>In conclusion, increased LVMi is reflected in abnormalities of GLS and the proportion of GLS impairment depends on the extent of LV hypertrophy. Therefore, simultaneous measurement of LVMi and GLS might be useful to identify patients at high risk for transition into heart failure who would benefit from aortic valve replacement irrespectively of LV EF.</p

    Plasma CCN2/connective tissue growth factor is associated with right ventricular dysfunction in patients with neuroendocrine tumors

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Carcinoid heart disease, a known complication of neuroendocrine tumors, is characterized by right heart fibrotic lesions. Carcinoid heart disease has traditionally been defined by the degree of valvular involvement. Right ventricular (RV) dysfunction due to mural involvement may also be a manifestation. Connective tissue growth factor (CCN2) is elevated in many fibrotic disorders. Its role in carcinoid heart disease is unknown. We sought to investigate the relationship between plasma CCN2 and valvular and mural involvement in carcinoid heart disease.</p> <p>Methods</p> <p>Echocardiography was performed in 69 patients with neuroendocrine tumors. RV function was assessed using tissue Doppler analysis of myocardial systolic strain. Plasma CCN2 was analyzed using an enzyme-linked immunosorbent assay. Mann-Whitney U, Kruskal-Wallis, Chi-squared and Fisher's exact tests were used to compare groups where appropriate. Linear regression was used to evaluate correlation.</p> <p>Results</p> <p>Mean strain was -21% ± 5. Thirty-three patients had reduced RV function (strain > -20%, mean -16% ± 3). Of these, 8 had no or minimal tricuspid and/or pulmonary regurgitation (TR/PR). Thirty-six patients had normal or mildly reduced RV function (strain ≤ -20%, mean -25% ± 3). There was a significant inverse correlation between RV function and plasma CCN2 levels (r = 0.47, p < 0.001). Patients with reduced RV function had higher plasma CCN2 levels than those with normal or mildly reduced RV function (p < 0.001). Plasma CCN2 ≥ 77 μg/L was an independent predictor of reduced RV function (odds ratio 15.36 [95% CI 4.15;56.86]) and had 88% sensitivity and 69% specificity for its detection (p < 0.001). Plasma CCN2 was elevated in patients with mild or greater TR/PR compared to those with no or minimal TR/PR (p = 0.008), with the highest levels seen in moderate to severe TR/PR (p = 0.03).</p> <p>Conclusions</p> <p>Elevated plasma CCN2 levels are associated with RV dysfunction and valvular regurgitation in NET patients. CCN2 may play a role in neuroendocrine tumor-related cardiac fibrosis and may serve as a marker of its earliest stages.</p

    Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography

    Get PDF
    BACKGROUND: The prosthesis used for aortic valve replacement in patients with small aortic root can be too small in relation to body size, thus showing high transvalvular gradients at rest and/or under stress conditions. This study was carried out to evaluate rest and Dobutamine stress echocardiography (DSE) hemodynamic response of 17-mm St. Jude Medical Regent (SJMR-17 mm) in relatively aged patients at mean 24 months follow-up. METHODS AND RESULTS: The study population consisted of 19 patients (2 men, 17 women, mean age 69.2 ± 7.3 years). All patients underwent rest Doppler echocardiography before and after surgery and basal and DSE at follow up (infused at rate of 5 micrg/Kg/min and increased by 5 microg/Kg/min at 5 min intervals up to 40 microg/Kg/min). The following parameters were evaluated at rest and/or under DSE: heart rate (HR), ejection fraction (EF), cardiac output (CO), peak and mean velocity and pressure gradients (MxV, MnV, MxPG, MnPG), effective orifice area (EOA), indexed EOA (EOAi), left ventricular mass (LVM), indexed LVM (LVMi), Velocity Time Integral at left ventricular outflow tract (VTI LVOT) and transvalvular (Aortic VTI), Doppler velocity index (DVI). At rest MxPG and MnPG were 29.2 ± 7.1 and 16.6 ± 5.8mmHg, respectively; EOA and EOAi resulted 1.14 ± 0.3 cm(2) and 0.76 ± 0.2 cm(2)/m(2); DVI was normal (0.50 ± 0.1). At follow-up LVM and LVMi decreased significantly from pre-operative value of 258 ± 43g and 157.4 ± 27.7g/m(2) to 191 ± 23.8g and 114.5 ± 10.6g/m(2), respectively. DSE increased significantly HR, CO, EF, MxGP (up to 83.4 ± 2 1.9mmHg), MnPG (up to 43.2 ± 12.7mmHg). EOA, EOAi, DVI increased insignificantly (from baseline up to 1.2 ± 0.4 cm(2), 0.75 ± 0.3cm(2)/m(2) and 0.48 ± 0.1 respectively). Two patients developed significant intraventricular gradients. CONCLUSION: These data show that SJMR 17-mm prostheses can be safely implanted in aortic position in relatively aged patients, offering a satisfactory hemodynamic performance at rest and under DSE, with full utilization of its available orifice, suggesting that a possible mild prosthesis-patient mismatch is not an issue of clinical relevance when this small prosthesis is used. Rest and Dobutamine stress echocardiography is a useful and effective means for evaluating prosthesis hemodynamics and for monitoring the expected LVH regression
    corecore