    An anisotropic elastic-viscoplastic damage model for bone tissue

    Get PDF
    A new anisotropic elastic-viscoplastic damage constitutive model for bone is proposed using an eccentric elliptical yield criterion and nonlinear isotropic hardening. A micromechanics-based multiscale homogenization scheme proposed by Reisinger etal. is used to obtain the effective elastic properties of lamellar bone. The dissipative process in bone is modeled as viscoplastic deformation coupled to damage. The model is based on an orthotropic ecuntric elliptical criterion in stress space. In order to simplify material identification, an eccentric elliptical isotropic yield surface was defined in strain space, which is transformed to a stress-based criterion by means of the damaged compliance tensor. Viscoplasticity is implemented by means of the continuous Perzyna formulation. Damage is modeled by a scalar function of the accumulated plastic strain D(κ){D(\kappa)} , reducing all element s of the stiffness matrix. A polynomial flow rule is proposed in order to capture the rate-dependent post-yield behavior of lamellar bone. A numerical algorithm to perform the back projection on the rate-dependent yield surface has been developed and implemented in the commercial finite element solver Abaqus/Standard as a user subroutine UMAT. A consistent tangent operator has been derived and implemented in order to ensure quadratic convergence. Correct implementation of the algorithm, convergence, and accuracy of the tangent operator was tested by means of strain- and stress-based single element tests. A finite element simulation of nano- indentation in lamellar bone was finally performed in order to show the abilities of the newly developed constitutive mode

    Nonlinear optical properties of push–pull polyenes for electro-optics

    Get PDF
    Improved nonlinear organic chromophores of varying conjugation length with either thiobarbituric acid or 3-dicyanomethylene-2,3-dihydrobenzothiophene-1,1-dioxide (FORON® Blue) acceptors have been synthesized and investigated for their nonlinear optical properties. Very large quadratic hyperpolarizabilities β(−2ω; ω, ω) have been found, up to 25,700×10^(−48) esu at λ=1.91 μm. In a guest–host polymer very high electro-optic (EO) coefficients, of up to 55 pm/V, have been determined at λ=1.31 μm with 20-wt % chromophore loading. We find good agreement between molecular parameters evaluated by electric-field-induced second-harmonic generation (EFISH) and the measurements of guest–host solid–solid solutions. The latter method is well suited to the determination of the product of dipole moment μ and hyperpolarizability β quickly and reliably at the wavelength of interest for EO applications without the complications associated with EFISH measurements

    Influence of Bacille Calmette-Guérin Vaccination on Size of Tuberculin Skin Test Reaction: To What Size?

    Get PDF
    Background. Previous bacillus Calmette-Guérin (BCG) vaccination can confound the results of a tuberculin skin test (TST). We sought to determine a cutoff diameter of TST induration beyond which the influence of BCG vaccination was negligible in evaluating potential Mycobacterium tuberculosis infection in a population of health care workers with a high vaccination rate and low incidence of tuberculosis. Methods. From 1991 through 1998, all new employees at the University Hospital of Lausanne, Switzerland, underwent a 2-step TST at entry visit. We also gathered information on demographic characteristics, along with factors commonly associated with tuberculin positivity, including previous BCG vaccination, history of latent M. tuberculosis infection, and predictors for M. tuberculosis infection. Results. Among the 5117 investigated subjects, we found that influence of BCG vaccination on TST results varied across categories of age (likelihood ratio test, 0.0001). Prior BCG vaccination had a strong influence on skin test results of ⩽18 mm in diameter among persons <40 years old, compared with the influence of factors predictive of M. tuberculosis infection. Prior latent M. tuberculosis infection and travel or employment in a country in which tuberculosis is endemic also had significant influences. Conclusions. Interpretation of TST reactions of ⩽18 mm among BCG-vaccinated persons <40 years of age must be done with caution in areas with a low incidence of tuberculosis. In such a population, except for persons who have never been vaccinated, TST reactions of ⩽18 mm are more likely to be the result of prior vaccination than infection and should not systematically lead to preventive treatmen

    Compliance of the L5-S1 spinal unit: a comparative study between an unconstrained and a partially constrained system

    Get PDF
    A comparison between an unconstrained and a partially constrained system for in vitro biomechanical testing of the L5-S1 spinal unit was conducted. The objective was to compare the compliance and the coupling of the L5-S1 unit measured with an unconstrained and a partially constrained test for the three major physiological motions of the human spine. Very few studies have compared unconstrained and partially constrained testing systems using the same cadaveric functional spinal units (FSUs). Seven human L5-S1 units were therefore tested on both a pneumatic, unconstrained, and a servohydraulic, partially constrained system. Each FSU was tested along three motions: flexion-extension (FE), lateral bending (LB) and axial rotation (AR). The obtained kinematics on both systems is not equivalent, except for the FE case, where both motions are similar. The directions of coupled motions were similar for both tests, but their magnitudes were smaller in the partially constrained configuration. The use of a partially constrained system to characterize LB and AR of the lumbosacral FSU decreased significantly the measured stiffness of the segment. The unconstrained system is today's "gold standard” for the characterization of FSUs. The selected partially constrained method seems also to be an appropriate way to characterize FSUs for specific applications. Care should be taken using the latter method when the coupled motions are importan

    Reference values and clinical predictors of bone strength for HR-pQCT-based distal radius and tibia strength assessments in women and men.

    Get PDF
    Reference values for radius and tibia strength using multiple-stack high-resolution peripheral quantitative computed tomography (HR-pQCT) with homogenized finite element analysis are presented in order to derive critical values improving risk prediction models of osteoporosis. Gender and femoral neck areal bone mineral density (aBMD) were independent predictors of bone strength. INTRODUCTION The purpose was to obtain reference values for radius and tibia bone strength computed by using the homogenized finite element analysis (hFE) using multiple stacks with a HR-pQCT. METHODS Male and female healthy participants aged 20-39 years were recruited at the University Hospital of Bern. They underwent interview and clinical examination including hand grip, gait speed and DXA of the hip. The nondominant forearm and tibia were scanned with a double and a triple-stack protocol, respectively, using HR-pQCT (XCT II, SCANCO Medical AG). Bone strength was estimated by using the hFE analysis, and reference values were calculated using quantile regression. Multivariable analyses were performed to identify clinical predictors of bone strength. RESULTS Overall, 46 women and 41 men were recruited with mean ages of 25.1 (sd 5.0) and 26.2 (sd 5.2) years. Sex-specific reference values for bone strength were established. Men had significantly higher strength for radius (mean (sd) 6640 (1800) N vs. 4110 (1200) N; p < 0.001) and tibia (18,200 (4220) N vs. 11,970 (3150) N; p < 0.001) than women. In the two multivariable regression models with and without total hip aBMD, the addition of neck hip aBMD significantly improved the model (p < 0.001). No clinical predictors of bone strength other than gender and aBMD were identified. CONCLUSION Reference values for radius and tibia strength using multiple HR-pQCT stacks with hFE analysis are presented and provide the basis to help refining accurate risk prediction models. Femoral neck aBMD and gender were significant predictors of bone strength

    A generalized anisotropic quadric yield criterion and its application to bone tissue at multiple length scales

    Get PDF
    Nonlinear computational analysis of materials showing elasto-plasticity or damage relies on knowledge of their yield behavior and strengths under complex stress states. In this work, a generalized anisotropic quadric yield criterion is proposed that is homogeneous of degree one and takes a convex quadric shape with a smooth transition from ellipsoidal to cylindrical or conical surfaces. If in the case of material identification, the shape of the yield function is not known a priori, a minimization using the quadric criterion will result in the optimal shape among the convex quadrics. The convexity limits of the criterion and the transition points between the different shapes are identified. Several special cases of the criterion for distinct material symmetries such as isotropy, cubic symmetry, fabric-based orthotropy and general orthotropy are presented and discussed. The generality of the formulation is demonstrated by showing its degeneration to several classical yield surfaces like the von Mises, Drucker-Prager, Tsai-Wu, Liu, generalized Hill and classical Hill criteria under appropriate conditions. Applicability of the formulation for micromechanical analyses was shown by transformation of a criterion for porous cohesive-frictional materials by Maghous et al. In order to demonstrate the advantages of the generalized formulation, bone is chosen as an example material, since it features yield envelopes with different shapes depending on the considered length scale. A fabric- and density-based quadric criterion for the description of homogenized material behavior of trabecular bone is identified from uniaxial, multiaxial and torsional experimental data. Also, a fabric- and density-based Tsai-Wu yield criterion for homogenized trabecular bone from in silico data is converted to an equivalent quadric criterion by introduction of a transformation of the interaction parameters. Finally, a quadric yield criterion for lamellar bone at the microscale is identified from a nanoindentation study reported in the literature, thus demonstrating the applicability of the generalized formulation to the description of the yield envelope of bone at multiple length scale

    Contact tracing investigation after professional exposure to tuberculosis in a Swiss hospital using both tuberculin skin test and IGRA.

    Get PDF
    SETTING: A 950 bed teaching hospital in Switzerland. AIM: To describe the result of a contact investigation among health care workers (HCW) and patients after exposure to a physician with smear-positive pulmonary tuberculosis in a hospital setting using standard tuberculin skin tests (TST) and Interferon-gamma release assay (IGRA). METHOD: HCW with a negative or unknown TST at hiring had a TST two weeks after the last contact with the index case (T0), repeated six weeks later if negative (T6). All exposed HCW had a T-SPOT.TB at T0 and T6. Exposed patients had a TST six weeks after the last contact, and a T-SPOT.TB if the TST was positive. RESULTS: Among 101 HCW, 17/73 (22%) had a positive TST at T0. TST was repeated in 50 at T6 and converted from negative to positive in eight (16%). Twelve HCW had a positive T-SPOT.TB at T0 and ten converted from negative to positive at T6. Seven HCW with a positive T-SPOT.TB reverted to negative at T6 or at later controls, most of them with test values close to the cut-off. Among 27 exposed patients tested at six weeks, ten had a positive TST, five of them confirmed by a positive T-SPOT.TB. CONCLUSIONS: HCW tested twice after exposure to a case of smear-positive pulmonary TB demonstrated a possible conversion in 10% with T-SPOT and 16% with TST. Some T-SPOT.TB reverted from positive to negative during the follow-up, mostly tests with a value close to the cut-off. Due to the variability of the test results, it seems advisable to repeat the test with values close to the cut-off before diagnosing the presence of a tuberculous infection

    75%-efficiency blue generation from an intracavity PPKTP frequency doubler

    Full text link
    We report on a high-efficiency 461 nm blue light conversion from an external cavity-enhanced second-harmonic generation of a 922 nm diode laser with a quasi-phase-matched KTP crystal (PPKTP). By choosing a long crystal (LC=20 mm) and twice looser focusing (w0=43 μ\mum) than the "optimal" one, thermal lensing effects due to the blue power absorption are minimized while still maintaining near-optimal conversion efficiency. A stable blue power of 234 mW with a net conversion efficiency of eta=75% at an input mode-matched power of 310 mW is obtained. The intra-cavity measurements of the conversion efficiency and temperature tuning bandwidth yield an accurate value d33(461 nm)=15 pm/V for KTP and provide a stringent validation of some recently published linear and thermo-optic dispersion data of KTP