41 research outputs found

    Introducing non-linear analysis into sustained speech characterization to improve sleep apnea detection

    Full text link
    The final publication is available at Springer via http://dx.doi.org/10.1007/978-3-642-25020-0_28Proceedings of 5th International Conference on Nonlinear Speech Processing, NOLISP 2011, Las Palmas de Gran Canaria (Spain)We present a novel approach for detecting severe obstructive sleep apnea (OSA) cases by introducing non-linear analysis into sustained speech characterization. The proposed scheme was designed for providing additional information into our baseline system, built on top of state-of-the-art cepstral domain modeling techniques, aiming to improve accuracy rates. This new information is lightly correlated with our previous MFCC modeling of sustained speech and uncorrelated with the information in our continuous speech modeling scheme. Tests have been performed to evaluate the improvement for our detection task, based on sustained speech as well as combined with a continuous speech classifier, resulting in a 10% relative reduction in classification for the first and a 33% relative reduction for the fused scheme. Results encourage us to consider the existence of non-linear effects on OSA patients’ voices, and to think about tools which could be used to improve short-time analysis.The activities described in this paper were funded by the Spanish Ministry of Science and Innovation as part of the TEC2009-14719-C02-02 (PriorSpeech) project

    Diabetes Is an Independent Risk Factor for Severe Nocturnal Hypoxemia in Obese Patients. A Case-Control Study

    Get PDF
    Type 2 diabetes mellitus (T2DM) and obesity have become two of the main threats to public health in the Western world. In addition, obesity is the most important determinant of the sleep apnea-hypopnea syndrome (SAHS), a condition that adversely affects glucose metabolism. However, it is unknown whether patients with diabetes have more severe SAHS than non-diabetic subjects. The aim of this cross-sectional case-control study was to evaluate whether obese patients with T2DM are more prone to severe SAHS than obese non-diabetic subjects.Thirty obese T2DM and 60 non-diabetic women closely matched by age, body mass index, waist circumference, and smoking status were recruited from the outpatient Obesity Unit of a university hospital. The exclusion criteria included chronic respiratory disease, smoking habit, neuromuscular and cerebrovascular disease, alcohol abuse, use of sedatives, and pregnancy. Examinations included a non-attended respiratory polygraphy, pulmonary function testing, and an awake arterial gasometry. Oxygen saturation measures included the percentage of time spent at saturations below 90% (CT90). A high prevalence of SAHS was found in both groups (T2DM:80%, nondiabetic:78.3%). No differences in the number of sleep apnea-hypopnea events between diabetic and non-diabetic patients were observed. However, in diabetic patients, a significantly increase in the CT90 was detected (20.2+/-30.2% vs. 6.8+/-13,5%; p = 0.027). In addition, residual volume (RV) was significantly higher in T2DM (percentage of predicted: 79.7+/-18.1 vs. 100.1+/-22.8; p<0.001). Multiple linear regression analyses showed that T2DM but not RV was independently associated with CT90.T2DM adversely affects breathing during sleep, becoming an independent risk factor for severe nocturnal hypoxemia in obese patients. Given that SAHS is a risk factor of cardiovascular disease, the screening for SAHS in T2DM patients seems mandatory

    Reliability of home CPAP titration with different automatic CPAP devices

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>CPAP titration may be completed by automatic apparatus. However, differences in pressure behaviour could interfere with the reliability of pressure recommendations. Our objective was to compare pressure behaviour and effective pressure recommendations between three Automatic CPAP machines (Autoset Spirit, Remstar Auto, GK 420).</p> <p>Methods</p> <p>Sixteen untreated obstructive sleep apnea patients were randomly allocated to one of the 3 tested machines for a one-week home titration trial in a crossover design with a 10 days washout period between trials.</p> <p>Results</p> <p>The median pressure value was significantly lower with machine GK 420 (5.9 +/- 1.8 cm H<sub>2</sub>O) than with the other devices both after one night and one week of CPAP titration (7.4 +/- 1.3 and 6.6 +/- 1.9 cm H<sub>2</sub>O). The maximal pressure obtained over the one-week titration was significantly higher with Remstar Auto (12.6 +/- 2.4 cm H<sub>2</sub>O, Mean +/- SD) than with the two other ones (10.9 +/- 1.0 and 11.0 +/- 2.4 cm H<sub>2</sub>O). The variance in pressure recommendation significantly differed between the three machines after one night and between Autoset Spirit and the two other machines after 1 week.</p> <p>Conclusion</p> <p>Pressure behaviour and pressure recommendation significantly differ between Auto CPAP machines both after one night and one week of home titration.</p

    Heuristics for apnea episodes recognition

    No full text
    International Conference on Soft Computing Models in Industrial and Environmental Applications (10. 2015
    corecore