453 research outputs found
Improving the detection of low concentration metabolites in magnetic resonance spectroscopy by digital filtering
In vivo detection and quantitation of metabolites is often limited by their low concentration. As far as magnetic resonance spectroscopy (MRS) is concerned, detection and quantitation can be significantly improved by reduction of the observed spectral width (SW). The reduction is limited to the spreading of resonances in the bandwidth unless high performance digital filters are used. Indeed, these filters avoid the folding of unwanted resonances such as water peak into the main frequency spectrum and therefore allow reduction of the spectral width to its optimal value. These filters are now available on most MRS systems but their use is not common even if, as we show in the particular case of proton MRS, a significant increase in signal-to-noise ratio (two-fold factor for SW reduction from 5000 Hz to 1351 Hz) can be achieved. This signal-to-noise improvement allows better quantitation accuracy
In Vivo Quantitative Microimaging of Rat Spinal Cord at 7T
International audienceIn vivo T(2), ADC, and MT properties of the GM and WM of the rat spinal cord were measured at 7T in the cervical region. The GM T(2), T(2GM) = 43.2 +/- 1.0 msec is significantly reduced compared to the WM T(2), T(2WM) = 57.0 +/- 1.6 msec. Diffusion is anisotropic for both GM and WM, with a larger ADC value along the cord axis (ADC(GM//) = 1.05 +/- 0.09 10(-9) m(2)sec(-1) and ADC(WM//) = 1.85 +/- 0.18 10(-9) m(2)sec(-1)) than perpendicular to this plane (ADC(GM)( perpendicular) approximately 0.50 * 10(-9) m(2)sec(-1) and ADC(WM)( perpendicular) approximately 0.18 * 10(-9) m(2)sec(-1)). The MT properties do not significantly differ between the WM and the GM, but allow one to distinguish the thin CSF layer from the WM. DWI with the sensitizing gradient perpendicular to the cord axis leads to the best contrast between GM and WM in the cervical region
Susceptibility gradient quantization by MRI signal response mapping (SIRMA) to dephaser
Purpose: Susceptibility effects are a very efficient source of contrast in magnetic resonance imaging. However, detection is hampered by the fact the induced contrast is negative. In this work, the SIgnal Response MApping (SIRMA) to dephaser method is proposed to map susceptibility gradient to improve visualization. Methods: In conventional gradient echo acquisitions, the echo formation of susceptibility affected spins is shifted in k -space, the shift being proportional to the susceptibility gradient. Susceptibility gradients map can be produced by measuring this induced shifts. The SIRMA method measures these shifts from a series of dephased images collected with additional incremental dephasers. These additional dephasers correspond either to a slice refocusing gradient offset or to a reconstruction window off-centering. The signal intensity profile as a function of the additional dephaser was determined on a pixel-by-pixel basis from the ensemble of dephased images. Susceptibility affected voxels presented a signal response profile maximum shifted compared to nonaffected voxels ones. Shift magnitude and sign were measured for each pixel to determine susceptibility gradients and produce a susceptibility gradient map. Results: In vitro experiments demonstrated the ability of the method to map gradient inhomogeneities induced by a cylinder. Quantization accuracy was evaluated comparing SIRMA images and simulations performed on the well-characterized air filled cylinder model. Performances of the SIRMA method, evaluated in vitro on cylinders filled with various superparamagnetic iron oxide SPIO concentrations, showed limited influence of acquisition parameters. Robustness of the method was then assessed in vivo after an infusion of SPIO-loaded nanocapsules into the rat brain using a convection-enhanced drug delivery approach. The region of massive susceptibility gradient induced by the SPIO-loaded nanocapsules was clearly delineated on SIRMA maps and images were compared to T 2 weighted images, Susceptibility Gradient Map (SGM), and histological Perl\u27s staining slice. The potential for quantitative evaluation of SPIO distribution volume was demonstrated. Conclusions: The proposed method is a promising technique for a wide range of applications especially in molecular or cellular imaging with respect to its quantitative nature and its computational simplicity
Three-dimensional MRI assessment of regional wall stress after acute myocardial infarction predicts postdischarge cardiac events
PURPOSE: To determine the prognostic significance of systolic wall stress (SWS) after reperfused acute myocardial infarction (AMI) using MRI. MATERIALS AND METHODS: A total of 105 patients underwent MRI 7.8 +/- 4.2 days after AMI reperfusion. SWS was calculated by using a three-dimensional (3D) MRI approach to left ventricular (LV) wall thickness and to the radius of curvature. Between hospital discharge and the end of follow-up, an average of 4.1 +/- 1.7 years after AMI, 19 patients experienced a major cardiac event, including cardiac death, nonfatal reinfarction or heart failure (18.3%). RESULTS: The results were mainly driven by heart failure outcome. In univariate analysis the following factors were predictive of postdischarge major adverse cardiac events: 1) at the time of AMI: higher heart rate, previous calcium antagonist treatment, in-hospital congestive heart failure, proximal left anterior descending artery (LAD) occlusion, a lower ejection fraction, higher maximal ST segment elevation before reperfusion, and ST segment reduction lower than 50% after reperfusion; 2) MRI parameters: higher LV end-systolic volume, lower ejection fraction, higher global SWS, higher SWS in the infarcted area (SWS MI) and higher SWS in the remote myocardium (SWS remote). In the final multivariate model, only SWS MI (odds ratio [OR]: 1.62; 95% confidence interval [CI]: 1.01-2.60; P = 0.046) and SWS remote (OR: 2.17; 95% CI: 1.02-4.65; P = 0.046) were independent predictors. CONCLUSION: Regional SWS assessed by means of MRI a few days after AMI appears to be strong predictor of postdischarge cardiac events, identifying a subset of at risk patients who could qualify for more aggressive management
Volumetric assessment of myocardial viability in rats using 3D double contrast enhanced T1 and T2-weighted MRI
OBJECTIVE: Volumetric evaluation of the myocardial viability post-infarction in rats using 3D in vivo MR imaging at 7 T using injection of an extracellular paramagnetic contrast agent and intravascular superparamagnetic iron oxide nanoparticles in the same imaging session.
MATERIALS AND METHODS: Five hours after induction of permanent myocardial infarction in rats (n=6), 3D in vivo T1- and T2-weighted MR Imaging was performed prior to and after Gd-DOTA injection (0.2 mmol/kg) and prior to and after nanoparticle injection (5 mg Fe/kg) to assess infarct size and myocardial viability.
RESULTS: 3D MR Imaging using a successive contrast agent injection showed a difference of infarct size after Gd-DOTA injection on T1-weighted images compared to the one measured on T2-weighted images after Gd-DOTA and nanoparticle injection.
CONCLUSION: The use of 3D T1- and T2-weighted MR Imaging using a double contrast agents protocol made possible the accurate characterization of myocardial infarction volume and allowed the detection of myocardial viability post-infarction in rats
Innovative Molecular Imaging for Clinical Research, Therapeutic Stratification, and Nosography in Neuroscience.
Over the past few decades, several radiotracers have been developed for neuroimaging applications, especially in PET. Because of their low steric hindrance, PET radionuclides can be used to label molecules that are small enough to cross the blood brain barrier, without modifying their biological properties. As the use of 11C is limited by its short physical half-life (20 min), there has been an increasing focus on developing tracers labeled with 18F for clinical use. The first such tracers allowed cerebral blood flow and glucose metabolism to be measured, and the development of molecular imaging has since enabled to focus more closely on specific targets such as receptors, neurotransmitter transporters, and other proteins. Hence, PET and SPECT biomarkers have become indispensable for innovative clinical research. Currently, the treatment options for a number of pathologies, notably neurodegenerative diseases, remain only supportive and symptomatic. Treatments that slow down or reverse disease progression are therefore the subject of numerous studies, in which molecular imaging is proving to be a powerful tool. PET and SPECT biomarkers already make it possible to diagnose several neurological diseases in vivo and at preclinical stages, yielding topographic, and quantitative data about the target. As a result, they can be used for assessing patients' eligibility for new treatments, or for treatment follow-up. The aim of the present review was to map major innovative radiotracers used in neuroscience, and explain their contribution to clinical research. We categorized them according to their target: dopaminergic, cholinergic or serotoninergic systems, β-amyloid plaques, tau protein, neuroinflammation, glutamate or GABA receptors, or α-synuclein. Most neurological disorders, and indeed mental disorders, involve the dysfunction of one or more of these targets. Combinations of molecular imaging biomarkers can afford us a better understanding of the mechanisms underlying disease development over time, and contribute to early detection/screening, diagnosis, therapy delivery/monitoring, and treatment follow-up in both research and clinical settings
Assessment of myocardial viability in rats: Evaluation of a new method using superparamagnetic iron oxide nanoparticles and Gd-DOTA at high magnetic field
The aim of this study was to detect salvageable peri-infarction myocardium by MRI in rats after infarction, using with a double contrast agent (CA) protocol at 7 Tesla. Intravascular superparamagnetic iron oxide (SPIO) nanoparticles and an extracellular paramagnetic CA (Gd-DOTA) were used to characterize the peri-infarction zone, which may recover function after reperfusion occurs. Infarcted areas measured from T1-weighted (T1-w) images post Gd-DOTA administration were overestimated compared to histological TTC staining (52% +/- 3% of LV surface area vs. 40% +/- 3%, P=0.03) or to T2-w images post SPIO administration (41% +/- 4%, P=0.04), whereas areas measured from T2-w images post SPIO administration were not significantly different from those measured histologically (P=0.7). Viable and nonviable myocardium portions of ischemically injured myocardium were enhanced after diffusive Gd-DOTA injection. The subsequent injection of vascular SPIO nanoparticles enables the discrimination of viable peri-infarction regions by specifically altering the signal of the still-vascularized myocardium
In vitro and in vivo evaluation of superparamagnetic iron oxide nanoparticles coated by bisphosphonates: the effects of electrical charge and molecule length.
Physicochemical coating properties are often considered to be determining factors for in vivo characteristics of superparamagnetic iron oxide nanoparticles, used as contrast agent in Magnetic Resonance Imaging (MRI). To investigate the electrical charge (modified by zero, one or two ammonium groups) and the molecule length (3, 5 or 7 methylene chains) effects of bisphosphonate-type coatings, we assessed the complement activation, in vivo plasma and tissue relaxation time alterations of intravenously injected small iron oxide nanoparticles (<25 nm) on male healthy Wistar rats. The presence of ammonium groups induces a weak activation of the complement whatever the size and the concentration of particles, whereas hydroxyethylenebisphosphonate (HEBP)-coated particles are poor complement activators only at the lowest concentration. In vivo, HEBP-coated nanoparticles have the greatest prolonged relaxation time effects, despite their higher negative electrical charge, contrary to two ammonium bearing coatings. No significant differences were observed between mono-ammonium molecular coatings
- …