271 research outputs found

    Use of Colour Duplex Ultrasound as a First Line Surveillance Tool Following EVAR is Associated with a Reduction in Cost Without Compromising Accuracy

    Get PDF
    CT scanning remains the postoperative surveillance imaging modality of choice following EVAR. Concerns regarding cost, exposure to ionising radiation and intravenous contrast have led to a search for a less expensive, equally efficacious and safer method of monitoring EVAR patients after endograft deployment. This study evaluated the cost saving obtained if CDUS was employed as a first line surveillance tool following EVAR, as well as comparing the two entities in terms of efficacy. Patients & methods: Postoperative surveillance CTs and CDUS scans in the 145 patients who have undergone EVAR from 1st June 2003 to 1st July 2010 were compared for the detection of endoleak and determination of residual sac size. Results: Adopting a protocol where CDUS was employed as the first line surveillance tool following EVAR would result in a reduction in the number of postoperative CTs required in 2010 from 235 to 36. Based on 2010 costings, this would equate to an estimated reduction in expenditure from V117,500 to V34,915 a saving of V82,585. CDUS had a sensitivity of 100% and a specificity of 85% in the detection of endoleaks compared to CT. The positive predictive value was 28% and negative predictive value 100%. The Pearson Coefficient correlation of 0.96 indicates a large degree of correlation between CDUS and CT when measuring residual aneurysm size following EVAR. Conclusion: CDUS can replace CT as the first line surveillance tool following EVAR. This is associated with a significant reduction in the cost of surveillance without any loss of imaging accurac

    Use of Colour Duplex Ultrasound as a First Line Surveillance Tool Following EVAR is Associated with a Reduction in Cost Without Compromising Accuracy

    Get PDF
    CT scanning remains the postoperative surveillance imaging modality of choice following EVAR. Concerns regarding cost, exposure to ionising radiation and intravenous contrast have led to a search for a less expensive, equally efficacious and safer method of monitoring EVAR patients after endograft deployment. This study evaluated the cost saving obtained if CDUS was employed as a first line surveillance tool following EVAR, as well as comparing the two entities in terms of efficacy. Patients & methods: Postoperative surveillance CTs and CDUS scans in the 145 patients who have undergone EVAR from 1st June 2003 to 1st July 2010 were compared for the detection of endoleak and determination of residual sac size. Results: Adopting a protocol where CDUS was employed as the first line surveillance tool following EVAR would result in a reduction in the number of postoperative CTs required in 2010 from 235 to 36. Based on 2010 costings, this would equate to an estimated reduction in expenditure from V117,500 to V34,915 a saving of V82,585. CDUS had a sensitivity of 100% and a specificity of 85% in the detection of endoleaks compared to CT. The positive predictive value was 28% and negative predictive value 100%. The Pearson Coefficient correlation of 0.96 indicates a large degree of correlation between CDUS and CT when measuring residual aneurysm size following EVAR. Conclusion: CDUS can replace CT as the first line surveillance tool following EVAR. This is associated with a significant reduction in the cost of surveillance without any loss of imaging accurac

    Epistemic and social scripts in computer-supported collaborative learning

    Get PDF
    Collaborative learning in computer-supported learning environments typically means that learners work on tasks together, discussing their individual perspectives via text-based media or videoconferencing, and consequently acquire knowledge. Collaborative learning, however, is often sub-optimal with respect to how learners work on the concepts that are supposed to be learned and how learners interact with each other. One possibility to improve collaborative learning environments is to conceptualize epistemic scripts, which specify how learners work on a given task, and social scripts, which structure how learners interact with each other. In this contribution, two studies will be reported that investigated the effects of epistemic and social scripts in a text-based computer-supported learning environment and in a videoconferencing learning environment in order to foster the individual acquisition of knowledge. In each study the factors ‘epistemic script’ and ‘social script’ have been independently varied in a 2×2-factorial design. 182 university students of Educational Science participated in these two studies. Results of both studies show that social scripts can be substantially beneficial with respect to the individual acquisition of knowledge, whereas epistemic scripts apparently do not to lead to the expected effects

    The systemic treatment of recurrent ovarian cancer revisited

    Get PDF
    Treatment approaches for relapsed ovarian cancer have evolved over the past decade from a calendar-based decision tree to a patient-oriented biologically driven algorithm. Nowadays, platinum-based chemotherapy should be offered to all patients with a reasonable chance of responding to this therapy. The treatment-free interval for platinum is only one of many factors affecting patients' eligibility for platinum re-treatment. Bevacizumab increases the response to chemotherapy irrespective of the cytotoxic regimen and can be valuable in patients with an urgent need for symptom relief (e.g. pleural effusion, ascites). For patients with recurrent high-grade ovarian cancer, which responds to platinum-based treatment, maintenance therapy with a poly(ADP-ribose) polymerase inhibitor can be offered, regardless of the BRCA mutation status. Here we review contemporary decision-making processes in the systemic treatment of relapsed ovarian cancer

    Can the Mechanism for π1ηπ,ηπ\pi_1\to \eta\pi,\eta'\pi Hybrid Decays be Detected?

    Full text link
    Two mechanisms for the π1\pi_1 (JPC=1+J^{PC}=1^{-+}) hybrid meson decay processes π1ηπ,ηπ\pi_1\to\eta\pi,\eta'\pi are investigated. These mechanisms are applied to ϕηγ,ηγ\phi\to\eta\gamma,\eta'\gamma and J/ψηγ,ηγJ/\psi\to\eta\gamma,\eta'\gamma decays to illustrate the validity of the decay mechanisms and to obtain independent information on the coupling of η,η\eta,\eta' to quark and gluonic operators. From this information, we find that Γ(π1ηπ)/Γ(π1ηπ)\Gamma(\pi_1\to\eta\pi)/\Gamma(\pi_1\to\eta'\pi) is substantially different in the two decay mechanisms, and hence future experimental measurements of this ratio will provide valuable information for substantiating the hybrid nature of these states and for determining the mechanism for these hybrid decays.Comment: 5 pages, revtex, 1 eps figure embedded in manuscript. Analysis and references extended in v

    QCD Sum Rule Analysis of the Decays BK+B \to K \ell^+ \ell^- and BK+B \to K^* \ell^+ \ell^-

    Full text link
    We use QCD sum rules to calculate the hadronic matrix elements governing the rare decays BK+B \to K \ell^+ \ell^- and BK+B \to K^* \ell^+ \ell^- induced by the flavour changing neutral current bsb \to s transition. We also study relations among semileptonic and rare BK()B \to K^{(*)} decay form factors. The analysis of the invariant mass distribution of the lepton pair in BK()+B \to K^{(*)} \ell^+ \ell^- and of the angular asymmetry in BK+B \to K^* \ell^+ \ell^- provides us with interesting tests of the Standard Model and its extensions.Comment: 26 pages REVTEX + 7 figures. Some typos corrected, figure 5 and 7 modified. This version will appear on Physical Review

    TNF-induced necroptosis in L929 cells is tightly regulated by multiple TNFR1 complex I and II members

    Get PDF
    TNF receptor 1 signaling induces NF-κB activation and necroptosis in L929 cells. We previously reported that cellular inhibitor of apoptosis protein-mediated receptor-interacting protein 1 (RIP1) ubiquitination acts as a cytoprotective mechanism, whereas knockdown of cylindromatosis, a RIP1-deubiquitinating enzyme, protects against tumor necrosis factor (TNF)-induced necroptosis. We report here that RIP1 is a crucial mediator of canonical NF-κB activation in L929 cells, therefore questioning the relative cytoprotective contribution of RIP1 ubiquitination versus canonical NF-κB activation. We found that attenuated NF-κB activation has no impact on TNF-induced necroptosis. However, we identified A20 and linear ubiquitin chain assembly complex as negative regulators of necroptosis. Unexpectedly, and in contrast to RIP3, we also found that knockdown of RIP1 did not block TNF cytotoxicity. Cell death typing revealed that RIP1-depleted cells switch from necroptotic to apoptotic death, indicating that RIP1 can also suppress apoptosis in L929 cells. Inversely, we observed that Fas-associated protein via a death domain, cellular FLICE inhibitory protein and caspase-8, which are all involved in the initiation of apoptosis, counteract necroptosis induction. Finally, we also report RIP1-independent but RIP3-mediated necroptosis in the context of TNF signaling in particular conditions

    Comparison of the Airtraq® and Truview® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation in manikins

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Paramedics are frequently required to perform tracheal intubation, a potentially life-saving manoeuvre in severely ill patients, in the prehospital setting. However, direct laryngoscopy is often more difficult in this environment, and failed tracheal intubation constitutes an important cause of morbidity. Novel indirect laryngoscopes, such as the Airtraq<sup>® </sup>and Truview<sup>® </sup>laryngoscopes may reduce this risk.</p> <p>Methods</p> <p>We compared the efficacy of these devices to the Macintosh laryngoscope when used by 21 Paramedics proficient in direct laryngoscopy, in a randomized, controlled, manikin study. Following brief didactic instruction with the Airtraq<sup>® </sup>and Truview<sup>® </sup>laryngoscopes, each participant took turns performing laryngoscopy and intubation with each device, in an easy intubation scenario and following placement of a hard cervical collar, in a SimMan<sup>® </sup>manikin.</p> <p>Results</p> <p>The Airtraq<sup>® </sup>reduced the number of optimization manoeuvres and reduced the potential for dental trauma when compared to the Macintosh, in both the normal and simulated difficult intubation scenarios. In contrast, the Truview<sup>® </sup>increased the duration of intubation attempts, and required a greater number of optimization manoeuvres, compared to both the Macintosh and Airtraq<sup>® </sup>devices.</p> <p>Conclusion</p> <p>The Airtraq<sup>® </sup>laryngoscope performed more favourably than the Macintosh and Truview<sup>® </sup>devices when used by Paramedics in this manikin study. Further studies are required to extend these findings to the clinical setting.</p
    corecore