93 research outputs found
Електронний підручник як засіб оптимізації післядипломної підготовки спеціалістів охорони здоров’я
Aim. To determine the scientific and methodological approaches to elaboration of electronic textbooks.Materials and methods. The methods of analysis and generalization were used in the study.Results. The study gave a possibility to assess domestic regulatory support for elaboration and implementation of electronic textbooks, define their types, basic characteristics and basic principles of development. The authorial definition of an “electronic textbook” and an algorithm to create electronic textbooks are presented.Conclusions. The algorithm for electronic textbook elaboration created in the study has been used to develop an electronic textbook of the second type “Pharmaceutical and biomedical aspects of medicines” for postgraduate training of healthcare professionals.Цель: определение научно-методических подходов к созданию электронного учебника.Материалы и методы. В работе были использованы методы анализа и обобщения.Результаты исследования. Изучено отечественное нормативное обеспечение создания и внедрения электронных учебников с обозначением их типов, базовых характеристик и основных принципов разработки. Представлены авторское определение понятия «электронный учебник» и алгоритм его создания.Выводы. Отработан алгоритм создания электронного учебника, на основании которого создан электронный учебник второго типа для системы последипломного образования специалистов охраны здоровья «Фармацевтические и медико-биологические аспекты лекарств».Мета: окреслення науково-методичних підходів до створення електронного підручника.Матеріали та методи. У роботі були використані методи аналізу та узагальнення.Результати дослідження. Вивчено вітчизняне нормативне забезпечення створення та упровадження електронних підручників із визначенням їх типів, базових характеристик та основних принципів розробки. Наведено авторське визначення поняття «електронний підручник» та алгоритм його створення.Висновки. Опрацьовано алгоритм створення електронного підручника, на основі якого розроблено електронний підручник другого типу для системи післядипломної освіти фахівців охорони здоров’я «Фармацевтичні та медико-біологічні аспекти ліків»
Design of beam optics for the Future Circular Collider e+e- -collider rings
A beam optics scheme has been designed for the Future Circular Collider-e+e-
(FCC-ee). The main characteristics of the design are: beam energy 45 to 175
GeV, 100 km circumference with two interaction points (IPs) per ring,
horizontal crossing angle of 30 mrad at the IP and the crab-waist scheme [1]
with local chromaticity correction. The crab-waist scheme is implemented within
the local chromaticity correction system without additional sextupoles, by
reducing the strength of one of the two sextupoles for vertical chromatic
correction at each side of the IP. So-called "tapering" of the magnets is
applied, which scales all fields of the magnets according to the local beam
energy to compensate for the effect of synchrotron radiation (SR) loss along
the ring. An asymmetric layout near the interaction region reduces the critical
energy of SR photons on the incoming side of the IP to values below 100 keV,
while matching the geometry to the beam line of the FCC proton collider
(FCC-hh) [2] as closely as possible. Sufficient transverse/longitudinal dynamic
aperture (DA) has been obtained, including major dynamical effects, to assure
an adequate beam lifetime in the presence of beamstrahlung and top-up
injection. In particular, a momentum acceptance larger than +/-2% has been
obtained, which is better than the momentum acceptance of typical collider
rings by about a factor of 2. The effects of the detector solenoids including
their compensation elements are taken into account as well as synchrotron
radiation in all magnets. The optics presented in this paper is a step toward a
full conceptual design for the collider. A number of issues have been
identified for further study
Status of the Super-B factory Design
The SuperB international team continues to optimize the design of an
electron-positron collider, which will allow the enhanced study of the origins
of flavor physics. The project combines the best features of a linear collider
(high single-collision luminosity) and a storage-ring collider (high repetition
rate), bringing together all accelerator physics aspects to make a very high
luminosity of 10 cm sec. This asymmetric-energy collider
with a polarized electron beam will produce hundreds of millions of B-mesons at
the (4S) resonance. The present design is based on extremely low
emittance beams colliding at a large Piwinski angle to allow very low
without the need for ultra short bunches. Use of crab-waist
sextupoles will enhance the luminosity, suppressing dangerous resonances and
allowing for a higher beam-beam parameter. The project has flexible beam
parameters, improved dynamic aperture, and spin-rotators in the Low Energy Ring
for longitudinal polarization of the electron beam at the Interaction Point.
Optimized for best colliding-beam performance, the facility may also provide
high-brightness photon beams for synchrotron radiation applications
Riistaeläinten populaatioiden dynamiikka Pohjois-Euroopassa: tiivistelmä : 7. kansainvälinen symposium. 24. – 28. Syyskuuta
We have studied Black Grouse population abundance and its dynamics in large regions of North-Europe and Urals’ taiga (Finland, Russian Karelia, Murmansk, Arhangel, Kirov and Komi regions and). The data is based on Winter Track Counts (WTC, Priklonski, 1973), where all grouse sightings are recorded. We also studied the longterm Black Grouse abundance changes in Russian and Belarus Natural Reserves (by “Chronical of Natural” Programme, including summer counts of forest grouses): Pinezhsky, Pechoro-Ilychskiy, National Park "Mechera", Nature Reserve "Kivach", "Bryansk Forest", Kostomuksha Nature Reserve Volzhsko-Kamsky National Nature Biosphere Reserve and Visimskiy State Nature Reserves. The highest and most stable abundances of Black Grouse were recorded from East Fennoscandia (Karelia – 3.6 birds per 10 km; Finland – 4.4, coefficient of variation – 12% and 27%, respectively), whereas in the Murmansk and Arkhangelsk Regions and Komi republic, e.g. the species abundance indices were 0.5, 2.5 and 1.1 birds per 10 km, respectively. The “Peak” and minimal abundance years do not concur in different regions of north-European taiga. In Komi in the period from 2001 to 2013, the number of the black grouse declined twice, in Arhangel in the period 30 years – decreased fivefold. In Tatarstan Republic (Volzhsko-Kamsky National Nature Biosphere Reserve) after 1980 abundance decreased rapidly and at last 10 tears – disappeared. In Central Siberia BG are small in numbers and rare. The data suggest Black Grouse abundance varies significantly across Northern Eurasia and among years. One may presume there are some factors acting in different directions: towards convergence and towards divergence of the trends.Peer reviewe
Precise measurement of and between 1.84 and 3.72 GeV at the KEDR detector
The present work continues a series of the KEDR measurements of the value
that started in 2010 at the VEPP-4M collider. By combining new data
with our previous results in this energy range we measured the values of
and at nine center-of-mass energies between 3.08 and 3.72
GeV. The total accuracy is about or better than at most of energy
points with a systematic uncertainty of about . Together with the
previous precise measurement at KEDR in the energy range 1.84-3.05 GeV, it
constitutes the most detailed high-precision measurement near the
charmonium production threshold.Comment: arXiv admin note: text overlap with arXiv:1610.02827 and substantial
text overlap with arXiv:1510.0266
Measurement of decay rate and parameters at KEDR
Using the inclusive photon spectrum based on a data sample collected at the
peak with the KEDR detector at the VEPP-4M collider, we
measured the rate of the radiative decay as well
as mass and width. Taking into account an asymmetric photon
lineshape we obtained keV, MeV/, MeV.Comment: 6 pages, 3 figure
- …