296 research outputs found

    Exponential Log-Periodic Antenna Design Using Improved Particle Swarm Optimization with Velocity Mutation

    Get PDF
    An improved particle swarm optimization (PSO) method applied to the design of a new wideband log-periodic antenna (LPA) geometry is introduced. This new PSO variant, called PSO with velocity mutation (PSOvm), induces mutation on the velocities of those particles that cannot improve their position. The proposed LPA consists of wire dipoles with lengths and distances varied according to an exponential rule, which is defined by two specific parameters called length factor and spacing factor. The LPA is optimized for operation in 790-6000MHz frequency range, in order to cover the most usual wireless services in practice, and also to provide in this range the highest possible forward gain, gain flatness below 2dB, secondary lobe level below –20dB with respect to the main lobe peak, and standing wave ratio below 2. To demonstrate its superiority in terms of performance, PSOvm is compared to well-known optimization methods. The comparison is performed by applying all the methods on several test functions and also on the LPA optimization problem defined by the above-mentioned requirements. Furthermore, the radiation characteristics of the PSOvm-based LPA give prominence to the effectiveness of the proposed exponential geometry compared to the traditional Carrel’s geometry

    Hybrid Diffuse Optical Techniques for Continuous Hemodynamic Measurement in Gastrocnemius During Plantar Flexion Exercise

    Get PDF
    Occlusion calibrations and gating techniques have been recently applied by our laboratory for continuous and absolute diffuse optical measurements of foreann muscle hemodynamics during handgrip exercises. The translation of these techniques from the foreann to the lower limb is the goal of this study as various diseases preferentially affect muscles in the lower extremity. This study adapted a hybrid near-infrared spectroscopy and diffuse correlation spectroscopy system with a gating algorithm to continuously quantify hemodynamic responses of medial gastrocnemius during plantar flexion exercises in 10 healthy subjects. The outcomes from optical measurement include oxy-, deoxy-, and total hemoglobin poncentrations, blood oxygen ~aturation, and relative changes in blood flow (rBF) and oxygen consumption rate (rV02) . We calibrated rBF and rV02 profiles with absolute baseline values of BF and V02 obtained by venous and arterial occlusions, respectively. Results from this investigation were comparable to values from similar studies. Additionally, significant correlation was observed between resting local muscle BF measured by the optical technique and whole limb BF measured concurrently by a strain gauge venous plethysmography. The extensive hemodynamic and metabolic profiles during exercise will allow for future comparison studies to investigate the diagnostic value of hybrid technologies in muscles affected by disease

    Two-Stage, 90-GHz, Low-Noise Amplifier

    Get PDF
    A device has been developed for coherent detection of the polarization of the cosmic microwave background (CMB). A two-stage amplifier has been designed that covers 75-110 GHz. The device uses the emerging 35-nm InP HEMT technology recently developed at Northrop Grumman Corporation primarily for use at higher frequencies. The amplifier has more than 18 dB gain and less than 35 K noise figure across the band. These devices have noise less than 30 K at 100 GHz. The development started with design activities at JPL, as well as characterization of multichip modules using existing InP. Following processing, a test campaign was carried out using single-chip modules at 100 GHz. Successful development of the chips will lead to development of multichip modules, with simultaneous Q and U Stokes parameter detection. This MMIC (monolithic microwave integrated circuit) amplifier takes advantage of performance improvements intended for higher frequencies, but in this innovation are applied at 90 GHz. The large amount of available gain ultimately leads to lower possible noise performance at 90 GHz

    Investigating the effect of child maltreatment on early adolescent peer-on-peer sexual aggression: testing a multiple mediator model in a non-incarcerated sample of Danish adolescents

    Get PDF
    Objective: The aim of the present study was to investigate the relationship between child maltreatment and severe early adolescent peer-on-peer sexual aggression, using a multiple mediator model. Methods: The study comprised 330 male Grade 9 students with a mean age of 14.9 years (SD=0.5). Results: Estimates from the mediation model indicated significant indirect effects of child physical abuse on sexual aggression via peer influence and insecure-hostile masculinity. No significant total effect of child sexual abuse and child neglect on sexual aggression was found. Conclusions: Findings of the present study identify risk factors that are potentially changeable and therefore of value in informing the design of prevention programs aiming at early adolescent peer-on-peer sexual aggression in at-risk youth

    Coital Experience Among Adolescents in Three Social-Educational Groups in Urban Chiang Mai, Thailand

    Get PDF
    This article compares coital experience of Chiang Mai 17–20-year-olds who were: (1) out-of-school; (2) studying at vocational schools; and (3) studying at general schools or university. Four-fifths, two-thirds and one-third, respectively, of males in these groups had had intercourse, compared to 53, 62 and 15 per cent of females. The gender difference for general school/university students, but not vocational school students, probably reflects HIV/AIDS refocusing male sexual initiation away from commercial sex workers. Vocational school females may have been disproportionately affected. Loss of virginity was associated, for both sexes, with social-educational background and lifestyle, and was less likely in certain minority ethnic groups. Among males, it was also associated with age and parental marital dissolution, and among females, with independent living and parental disharmony. Within social-educational groups, lifestyle variables dominated, but among general school/university students, parental marital dissolution (for males) and disharmony (for females) were also important, and Chinese ethnicity deterred male sexual experimentation

    To retain or remove the syndesmotic screw: a review of literature

    Get PDF
    Introduction: Syndesmotic positioning screws are frequently placed in unstable ankle fractures. Many facets of adequate placement techniques have been the subject of various studies. Whether or not the syndesmosis screw should be removed prior to weight-bearing is still debated. In this study, the recent literature is reviewed concerning the need for removal of the syndesmotic screw. Materials and methods: A comprehensive literature search was conducted in the electronic databases of the Cochrane Library, Pubmed Medline and EMbase from January 2000 to October 2010. Results: A total of seven studies were identified in the literature. Most studies found no difference in outcome between retained or removed screws. Patients with screws that were broken, or showed loosening, had similar or improved outcome compared to patients with removed screws. Removal of the syndesmotic screws, when deemed necessary, is usually not performed before 8-12 weeks. Conclusion: There is paucity in randomized controlled trials on the absolute need for removal of the syndesmotic screw. However, current literature suggests that it might be reserved for intact screws that cause hardware irritation or reduced range of motion after 4-6 months

    Changes in Inflammatory Response after Endovascular Treatment for Type B Aortic Dissection

    Get PDF
    This present study aims to investigate the changes in the inflammatory markers after elective endovascular treatment of Type B aortic dissection with aneurysm, as related to different anatomical features of the dissection flap in the paravisceral perfusion. Consecutive patients with type B aortic dissections with elective endovascular stent graft repair were recruited and categorized into different groups. Serial plasma levels of cytokines (Interleukin-1β, -6, -8, -10, TNF-α), chemokines (MCP-1), and serum creatinine were monitored at pre-, peri- and post-operative stages. The length of stent graft employed in each surgery was retrieved and correlated with the change of all studied biochemical parameters. A control group of aortic dissected patients with conventional medication management was recruited for comparing the baseline biochemical parameters. In total, 22 endovascular treated and 16 aortic dissected patients with surveillance were recruited. The endovascular treated patients had comparable baseline levels as the non-surgical patients. There was no immediate or thirty day-mortality, and none of the surgical patients developed post-operative mesenteric ischaemia or clinically significant renal impairment. All surgical patients had detectable pro-inflammatory mediators, but none of the them showed any statistical significant surge in the peri-operative period except IL-1β and IL-6. Similar results were obtained when categorized into different groups. IL-1β and IL-6 showed maximal levels within hours of the endovascular procedure (range, 3.93 to 27.3 higher than baseline; p = 0.001), but returned to baseline 1 day post-operatively. The change of IL-1β and IL-6 at the stent graft deployment was statistically greater in longer stent graft (p>0.05). No significant changes were observed in the serum creatinine levels. In conclusion, elective endovascular repair of type B aortic dissection associated with insignificant changes in inflammatory mediators and creatinine. All levels fell toward basal levels post-operatively suggesting that thoracic endovascular aortic repair is rather less aggressive with insignificant inflammatory modulation

    Modular hybrid total hip arthroplasty. Experimental study in dogs

    Get PDF
    Background: This prospective experimental study evaluated the surgical procedure and results of modular hybrid total hip arthroplasty in dogs.Methods: Ten skeletally mature healthy mongrel dogs with weights varying between 19 and 27 kg were used. Cemented modular femoral stems and uncemented porous-coated acetabular cups were employed. Clinical and radiographic evaluations were performed before surgery and at 30, 60, 90, 120, 180 and 360 days post-operation.Results: Excellent weight bearing was noticed in the operated limb in seven dogs. Dislocation followed by loosening of the prosthesis was noticed in two dogs, which were therefore properly treated with a femoral head osteotomy. Femoral fracture occurred in one dog, which was promptly treated with full implant removal and femoral osteosynthesis.Conclusions: The canine modular hybrid total hip arthroplasty provided excellent functionality of the operated limb
    corecore