55 research outputs found

    Chronic mild stress alters the somatostatin receptors in the rat brain

    Get PDF
    RATIONALE: The involvement of somatostatin (SST) and its receptors in the pathophysiology of depression and stress has been evidenced by numerous studies. OBJECTIVES: The purpose of the present study was to find whether chronic mild stress (CMS), an animal model of depression, affects the SST receptors in the rat brain and pituitary, as well as the level of SST in plasma. METHODS: In CMS model, rats were subjected to 2 weeks of stress and behaviorally characterized using the sucrose consumption test into differently reacting groups based on their response to stress, i.e., stress-reactive (anhedonic), stress-non-reactive (resilient), and invert-reactive rats (characterized by excessive sucrose intake). We measured specific binding of [(125)I]Tyr(3)-Octreotide, expression of mRNA encoding sst2R receptors in the rat brains, expression of SST and its receptors in rat pituitary, and the level of SST in the plasma. RESULTS: The obtained results show decreases in binding of [(125)I]Tyr(3)-Octreotide in most of rat brain regions upon CMS and no significant differences between three stressed groups of animals, except for significant up-regulation of sst2 receptor in medial habenula (MHb) in the stress-reactive group. In the same group of animals, significant increase in plasma SST level was observed. CONCLUSIONS: There are two particularly sensitive sites distinguishing the response to stress in CMS model. In the brain, it is MHb, while on the periphery this predictor is SST level in plasma. These changes may broaden an understanding of the mechanisms involved in the stress response and point to the intriguing role of MHb

    Use of Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry to Demonstrate Decreased Serum Statin Levels after Extracorporeal LDL-Cholesterol Elimination

    Get PDF
    Background. Using our statin analysis method, it was possible to uncover a significant drop in statin levels (atorvastatin, simvastatin, and metabolites) after extracorporeal LDL-cholesterol elimination (EE) in severe familial hypercholesterolemia (FH). The purpose of this work was to identify the mechanism underlying this drop and its clinical significance as well as to propose measures to optimize a pharmacotherapeutical regimen that can prevent the loss of statins. Methods. Ultra High Performance Liquid Chromatography (UHPLC) connected to the triple quadrupole MS/MS system was used. Patients. A group of long-term treated patients (3–12 years of treatment) with severe FH (12 patients) and treated regularly by LDL-apheresis (immunoadsorption) or haemorheopheresis (cascade filtration) were included in this study. Results. After EE, the level of statins and their metabolites decreased (atorvastatin before/after LDL-apheresis: 8.83/3.46 nmol/l; before/after haemorheopheresis: 37.02/18.94 nmol/l). A specific loss was found (concentration of atorvastatin for LDL-apheresis/haemorheopheresis: 0.28/3.04 nmol/l in washing fluids; 11.07 nmol/l in filters). To prevent substantial loss of statin concentrations, a pharmacotherapeutic regimen with a longer time interval between the dose of statins and EE is recommended (15 hours). Conclusions. A specific loss of statins was found in adsorbent columns and filters. The decrease can be prevented by the suggested dosage scheme

    Screening of conditions controlling spectrophotometric sequential injection analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Despite its potential benefits over univariate, chemometrics is rarely utilized for optimizing sequential injection analysis (SIA) methods. Specifically, in previous vis-spectrophotometric SIA methods, chemometrically optimized conditions were confined within flow rate and reagent concentrations while other conditions were ignored.</p> <p>Results</p> <p>The current manuscript reports, for the first time, a comprehensive screening of conditions controlling vis-spectrophotometric SIA. A new diclofenac assay method was adopted. The method was based on oxidizing diclofenac by permanganate (a major reagent) with sulfuric acid (a minor reagent). The reaction produced a spectrophotometrically detectable diclofenac form. The 2<sup>6 </sup>full-factorial design was utilized to study the effect of volumes of reagents and sample, in addition to flow rate and concentrations of reagents. The main effects and all interaction order effects on method performance, i.e. namely sensitivity, rapidity and reagent consumption, were determined. The method was validated and applied to pharmaceutical formulations (tablets, injection and gel).</p> <p>Conclusions</p> <p>Despite 64 experiments those conducted in the current study were cumbersome, the results obtained would reduce effort and time when developing similar SIA methods in the future. It is recommended to critically optimize effective and interacting conditions using other such optimization tools as fractional-factorial design, response surface and simplex, rather than full-factorial design that used at an initial optimization stage. In vis-spectrophotometric SIA methods those involve developing reactions with two reagents (major and minor), conditions affecting method performance are in the following order: sample volume > flow rate ≈ major reagent concentration >> major reagent volume ≈ minor reagent concentration >> minor reagent volume.</p

    Validation of an Analytical Methodology for Determination of Oxytetracycline and Tetracycline Residues in Honey by HPLC with Fluorescence Detection

    Get PDF
    An analytical method for the determination of OTC and TC residues in honey was developed. Sample treatment involves an extraction in EDTA-McIlvaine buffer, followed by a solid-phase cleanup step. With regard to the cleanup procedure, different SPE cartridges were evaluated and the results presented. The method was validated according to the guidelines laid down by the 2002/657/EC European Decision parameters: decision limit (Ccα) and detection capability (CCβ) were 20 and 21 μg/Kg and 49 and 50 μg/Kg for OTC and TC, respectively, and recoveries of OTC and TC from spiked samples, at three fortification levels, were higher than 87% for both compounds. The analytical method was applied to 57 honey samples

    Automated flow injection fluorimetric determination and dissolution studies of bumetanide in pharmaceuticals

    No full text
    A novel, sensitive and automated flow injection (FI) method with fluorimetric detection based on the strong fluorescence in alkaline medium has been developed for the assay, content uniformity and automated dissolution studies of bumetanide in pharmaceutical dosage forms. A fully automated FIA system controlled by home-made software (FIA-MOD 2.2.) was used for optimising the chemical and manifold parameters and running of routine measurements. The optimum excitation wavelength for bumetanide is 314 nm and emission wavelength ≥370 nm. The measurement throughput is 60 h-1 using 110 μl sample volume. The useful concentration range is 0.05-10.0 μgml-1 with an R.S.D. of 0.46% (n = 3; c = 1.0 μgml-1). Common excipients for tablets and injections were found not interfering. The assay results of two commercial drug formulations (tablets and injections) obtained with the proposed method agreed well with those obtained with the current USP method (HPLC-UV detection). Using this automated method the complete dissolution profile of bumetanide tablets was obtained. © 2001 Elsevier Science B.V
    corecore