463 research outputs found
Detection of liquid xenon scintillation light with a Silicon Photomultiplier
We have studied the feasibility of a silicon photomultiplier (SiPM) to detect
liquid xenon (LXe) scintillation light. The SiPM was operated inside a small
volume of pure LXe, at -95 degree Celsius, irradiated with an internal Am-241
alpha source. The gain of the SiPM at this temperature was estimated to be 1.8
x 10^6 with bias voltage at 52 V. Based on the geometry of the setup, the
quantum efficiency of the SiPM was estimated to be 22% at the Xe wavelength of
178 nm. The low excess noise factor, high single photoelectron detection
efficiency, and low bias voltage of SiPMs make them attractive alternative UV
photon detection devices to photomultiplier tubes (PMTs) for liquid xenon
detectors, especially for experiments requiring a very low energy detection
threshold, such as neutralino dark matter searches
Performance of a cryogenic system prototype for the XENON1T Detector
We have developed an efficient cryogenic system with heat exchange and
associated gas purification system, as a prototype for the XENON1T experiment.
The XENON1T detector will use about 3 ton of liquid xenon (LXe) at a
temperature of 175K as target and detection medium for a dark matter search. In
this paper we report results on the cryogenic system performance focusing on
the dynamics of the gas circulation-purification through a heated getter, at
flow rates above 50 Standard Liter per Minute (SLPM). A maximum flow of 114
SLPM has been achieved, and using two heat exchangers in parallel, a heat
exchange efficiency better than 96% has been measured
Study of the system in the mass range up to 1200 MeV
The reaction has been studied with GAMS-2000
spectrometer in the secondary 38 GeV/c -beam of the IHEP U-70
accelerator. Partial wave analysis of the reaction has been performed in the
mass range up to 1200 MeV. The -meson is seen as a sharp
peak in S-wave. The -dependence of production cross section has
been studied. Dominant production of the at a small transfer
momentum confirms the hypothesis of Achasov and Shestakov about significant
contribution of the exchange () in the mechanism
of meson production in -channel of the reaction.Comment: 4 pages, 3 figures, talk given at HADRON'9
Design and Performance of the XENON10 Dark Matter Experiment
XENON10 is the first two-phase xenon time projection chamber (TPC) developed
within the XENON dark matter search program. The TPC, with an active liquid
xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground
laboratory (LNGS) in Italy, and operated for more than one year, with excellent
stability and performance. Results from a dark matter search with XENON10 have
been published elsewhere. In this paper, we summarize the design and
performance of the detector and its subsystems, based on calibration data using
sources of gamma-rays and neutrons as well as background and Monte Carlo
simulations data. The results on the detector's energy threshold, energy and
position resolution, and overall efficiency show a performance that exceeds
design specifications, in view of the very low energy threshold achieved (<10
keVr) and the excellent energy resolution achieved by combining the ionization
and scintillation signals, detected simultaneously
First Results from the XENON10 Dark Matter Experiment at the Gran Sasso National Laboratory
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg
xenon dual phase time projection chamber (XeTPC) to search for dark matter
weakly interacting massive particles (WIMPs). The detector measures
simultaneously the scintillation and the ionization produced by radiation in
pure liquid xenon, to discriminate signal from background down to 4.5 keV
nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired
between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4
kg, excludes previously unexplored parameter space, setting a new 90% C.L.
upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x
10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a
WIMP mass of 30 GeV/c^2. This result further constrains predictions of
supersymmetric models.Comment: accepted for publication in Phys. Rev. Let
3D Position Sensitive XeTPC for Dark Matter Search
The technique to realize 3D position sensitivity in a two-phase xenon time
projection chamber (XeTPC) for dark matter search is described. Results from a
prototype detector (XENON3) are presented.Comment: Presented at the 7th UCLA Symposium on "Sources and Detection of Dark
Matter and Dark Energy in the Universe
Constraints on inelastic dark matter from XENON10
It has been suggested that dark matter particles which scatter inelastically
from detector target nuclei could explain the apparent incompatibility of the
DAMA modulation signal (interpreted as evidence for particle dark matter) with
the null results from CDMS-II and XENON10. Among the predictions of
inelastically interacting dark matter are a suppression of low-energy events,
and a population of nuclear recoil events at higher nuclear recoil equivalent
energies. This is in stark contrast to the well-known expectation of a falling
exponential spectrum for the case of elastic interactions. We present a new
analysis of XENON10 dark matter search data extending to E keV
nuclear recoil equivalent energy. Our results exclude a significant region of
previously allowed parameter space in the model of inelastically interacting
dark matter. In particular, it is found that dark matter particle masses
GeV are disfavored.Comment: 8 pages, 4 figure
A search for light dark matter in XENON10 data
We report results of a search for light (<10 GeV) particle dark matter with
the XENON10 detector. The event trigger was sensitive to a single electron,
with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear
recoil energy. Considering spin-independent dark matter-nucleon scattering, we
exclude cross sections \sigma_n>3.5x10^{-42} cm^2, for a dark matter particle
mass m_{\chi}=8 GeV. We find that our data strongly constrain recent elastic
dark matter interpretations of excess low-energy events observed by CoGeNT and
CRESST-II, as well as the DAMA annual modulation signal.Comment: Manuscript identical to v2 (published version) but also contains
erratum. Note v3==v2 but without \linenumber
- …