35 research outputs found

    Painful knee joint after ACL reconstruction using biodegradable interference screws- SPECT/CT a valuable diagnostic tool? A case report

    Get PDF
    With the presented case we strive to introduce combined single photon emission computerized tomography and conventional computer tomography (SPECT/CT) as new diagnostic imaging modality and illustrate the possible clinical value in patients after ACL reconstruction. We report the case of a painful knee due to a foreign body reaction and delayed degradation of the biodegradable interference screws after ACL reconstruction. The MRI showed an intact ACL graft, a possible tibial cyclops lesion and a patella infera. There was no increased fluid collection within the bone tunnels. The 99mTc-HDP-SPECT/CT clearly identified a highly increased tracer uptake around and within the tibial and femoral tunnels and the patellofemoral joint. On 3D-CT out of the SPECT/CT data the femoral graft attachment was shallow (50% along the Blumensaat's line) and high in the notch. At revision arthroscopy a diffuse hypertrophy of the synovium, scarring of the Hoffa fat pad and a cyclops lesion of the former ACL graft was found. The interference screws were partially degraded and under palpation and pressure a grey fluid-like substance drained into the joint. The interference screws and the ACL graft were removed and an arthrolysis performed

    Mesenchymal stem cells secretome-induced axonal outgrowth is mediated by BDNF

    Get PDF
    Mesenchymal stem cells (MSCs) have been used for cell-based therapies in regenerative medicine, with increasing importance in central and peripheral nervous system repair. However, MSCs grafting present disadvantages, such as, a high number of cells required for transplantation and low survival rate when transplanted into the central nervous system (CNS). In line with this, MSCs secretome which present on its composition a wide range of molecules (neurotrophins, cytokines) and microvesicles, can be a solution to surpass these problems. However, the effect of MSCs secretome in axonal elongation is poorly understood. In this study, we demonstrate that application of MSCs secretome to both rat cortical and hippocampal neurons induces an increase in axonal length. In addition, we show that this growth effect is axonal intrinsic with no contribution from the cell body. To further understand which are the molecules required for secretome-induced axonal outgrowth effect, we depleted brain-derived neurotrophic factor (BDNF) from the secretome. Our results show that in the absence of BDNF, secretome-induced axonal elongation effect is lost and that axons present a reduced axonal growth rate. Altogether, our results demonstrate that MSCs secretome is able to promote axonal outgrowth in CNS neurons and this effect is mediated by BDNF.European Regional Development Fund (ERDF), through the Centro 2020 Regional Operational Programme under project CENTRO-01–0145-FEDER-000008:BrainHealth 2020, and through the COMPETE 2020 - Operational Programme for Competitiveness and Internationalisation and Portuguese national funds via FCT – Fundação para a Ciência e a Tecnologia, I.P., under projects PTDC/SAU-NEU/104100/2008, EXPL/NEU-NMC/0541/2012 and UID/NEU/04539/2013. This work was also funded by Marie Curie Actions - International reintegration grant #249288, 7th Framework programme, EU. Partially funded by Prémios Santa Casa Neurociências - Prize Melo e Castro for Spinal Cord Injury Research; Portuguese Foundation for Science and Technology (IF Development Grant to A.J.S.); NORTE-01-0145-FEDER-000013, supported by the Northern Portugal Regional Operational Programme; by FEDER funds, through the Competitiveness Factors Operational Programme (COMPETE), and by national funds, through the Foundation for Science and Technology (FCT), under the scope of the project POCI-01-0145-FEDER-007038. The authors would also like to acknowledge Prof. J.E. Davies from the Institute of Biomaterials and Biomedical Engineering at the University of Toronto, Canada, for kindly providing some of the HUCPVCs lots used in the present workinfo:eu-repo/semantics/publishedVersio

    The position and orientation of total knee replacement components : a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction

    No full text
    We studied the intra- and interobserver reliability of measurements of the position of the components after total knee replacement (TKR) using a combination of radiographs and axial two-dimensional (2D) and three-dimensional (3D) reconstructed CT images to identify which method is best for this purpose. A total of 30 knees after primary TKR were assessed by two independent observers (an orthopaedic surgeon and a radiologist) using radiographs and CT scans. Plain radiographs were highly reliable at measuring the tibial slope, but showed wide variability for all other measurements; 2D-CT also showed wide variability. 3D-CT was highly reliable, even when measuring rotation of the femoral components, and significantly better than 2D-CT. Interobserver variability in the measurements on radiographs were good (intraclass correlation coefficient (ICC) 0.65 to 0.82), but rotational measurements on 2D-CT were poor (ICC 0.29). On 3D-CT they were near perfect (ICC 0.89 to 0.99), and significantly more reliable than 2D-CT (p > 0.001). 3D-reconstructed images are sufficiently reliable to enable reporting of the position and orientation of the components. Rotational measurements in particular should be performed on 3D-reconstructed CT images. When faced with a poorly functioning TKR with concerns over component positioning, we recommend 3D-CT as the investigation of choice

    A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography

    No full text
    SPECT/CT is a promising diagnostic modality in patients with painful total knee arthroplasty (TKA). The purpose of this study is to introduce a novel standardized SPECT/CT algorithm and evaluate its clinical application and reliability. A novel SPECT/CT localization scheme consisting of 9 tibial, 9 femoral and 4 patellar regions on standardized axial, coronal and sagittal slices is proposed. It was piloted in 18 consecutive patients with post TKA pain. The tracer activity on SPECT/CT was recorded using a color-coded scale (0-10). The inter- and intra-observer reliability was assessed for localization and tracer activity. The prosthetic component position was assessed in the CT images after 3D reconstruction using standardized frames of reference. The median inter- and intra-observer differences and ranges of the measured angles were calculated along with the ICC values for inter- and intra-observer reliability. The localization scheme showed very high inter- and intra-observer reliabilities for all regions. The measurement of component position was highly reliable in all cases with sufficient visibility of anatomical landmarks. The median inter-observer difference between alignment measurements for tibial and femoral components was less than 3 degrees (range 0 degrees -6 degrees ). The median intra-observer variability for these was less than 2 degrees (range 0 degrees -5 degrees ). The SPECT/CT algorithm presented is both reliable and useful in the management of patients with painful TKA. It combines biomechanical and metabolic data (tracer localization) providing an extra dimension to the understanding of this difficult condition. The clinical value of SPECT/CT in patients with unexplained pain following TKA should be further investigated
    corecore