654 research outputs found

    Saccadic selection and crowding in visual search:stronger lateral masking leads to shorter search times

    Get PDF
    We investigated the role of crowding in saccadic selection during visual search. To guide eye movements, often information from the visual periphery is used. Crowding is known to deteriorate the quality of peripheral information. In four search experiments, we studied the role of crowding, by accompanying individual search elements by flankers. Varying the difference between target and flankers allowed us to manipulate crowding strength throughout the stimulus. We found that eye movements are biased toward areas with little crowding for conditions where a target could be discriminated peripherally. Interestingly, for conditions in which the target could not be discriminated peripherally, this bias reversed to areas with strong crowding. This led to shorter search times for a target presented in areas with stronger crowding, compared to a target presented in areas with less crowding. These findings suggest a dual role for crowding in visual search. The presence of flankers similar to the target deteriorates the quality of the peripheral target signal but can also attract eye movements, as more potential targets are present over the area

    A priori model independent inverse potential mapping: the impact of electrode positioning

    Get PDF
    __Introduction:__ In inverse potential mapping, local epicardial potentials are computed from recorded body surface potentials (BSP). When BSP are recorded with only a limited number of electrodes, in general biophysical a priori models are applied to facilitate the inverse computation. This study investigated the possibility of deriving epicardial potential information using only 62 torso electrodes in the absence of an a priori model. __Methods:__ Computer simulations were used to determine the optimal in vivo positioning of 62 torso electrodes. Subsequently, three different electrode configurations, i.e., surrounding the thorax, concentrated precordial (30 mm inter-electrode distance) and super-concentrated precordial (20 mm inter-electrode distance) were used to record BSP from three healthy volunteers. Magnetic resonance imaging (MRI) was performed to register the electrode positions with respect to the anatomy of the patient. Epicardial potentials were inversely computed from the recorded BSP. In order to determine the reconstruction quality, the super-concentrated electrode configuration was applied in four patients with an implanted MRI-conditional pacemaker system. The distance between the position of the ventricular lead tip on MRI and the inversely reconstructed pacing site was determined. __Results:__ The epicardial potential distribution reconstructed using the super-concentrated electrode configuration demonstrated the highest correlation (R = 0.98; p < 0.01) with the original epicardial source model. A mean localization error of 5.3 mm was found in the pacemaker patients. __Conclusion:__ This study demonstrated the feasibility of deriving detailed anterior epicardial potential information using only 62 torso electrodes without the use of an a priori model

    Anomalous Transient Current in Nonuniform Semiconductors

    Full text link
    Nonequilibrium processes in semiconductors are considered with highly nonuniform initial densities of charge carriers. It is shown that there exist such distributions of charge densities under which the electric current through a sample displays quite abnormal behaviour flowing against the applied voltage. The appearance of this negative electric current is a transient phenomenon occurring at the initial stage of the process. After this anomalous negative fluctuation, the electric current becomes normal, i.e. positive as soon as the charge density becomes more uniform. Several possibilities for the practical usage of this effect are suggested.Comment: 1 file, 11 pages, RevTex, no figure

    Integrated whole-heart computational workflow for inverse potential mapping and personalized simulations

    Get PDF
    Background: Integration of whole-heart activation simulations and inverse potential mapping (IPM) could benefit the guidance and planning of electrophysiological procedures. Routine clinical application requires a fast and adaptable workflow. These requirements limit clinical translation of existing simulation models. This study proposes a comprehensive finite element model (FEM) based whole-heart computational workflow suitable for IPM and simulations. Methods: Three volunteers and eight patients with premature ventricular contractions underwent body surface potential (BSP) acquisition followed by a cardiac MRI (CMR) scan. The cardiac volumes were segmented from the CMR images using custom written software. The feasibility to integrate tissue-characteristics was assessed by generating meshes with virtual edema and scar. Isochronal activation maps were constructed by identifying the fastest route through the cardiac volume using the Möller-Trumbore and Floyd-Warshall algorithms. IPM's were reconstructed from the BSP's. Results: Whole-heart computational meshes were generated within seconds. The first point of atrial activation on IPM was located near the crista terminalis of the superior vena cave into the right atrium. The IPM demonstrated the ventricular epicardial breakthrough at the attachment of the moderator band with the right ventricular free wall. Simulations of sinus rhythm were successfully performed. The conduction through the virtual edema and scar meshes demonstrated delayed activation or a complete conductional block respectively. Conclusion: The proposed FEM based whole-heart computational workflow offers an integrated platform for cardiac electrical assessment using simulations and IPM. This workflow can incorporate patient-specific electrical parameters, perform whole-heart cardiac activation simulations and accurately reconstruct cardiac activation sequences from BSP's

    Low energy excitations in crystalline perovskite oxides: Evidence from noise experiments

    Get PDF
    In this paper we report measurements of 1/f noise in a crystalline metallic oxide with perovskite structure down to 4.2K. The results show existence of localized excitations with average activation energy ≈\approx 70-80 meV which produce peak in the noise at T ≈\approx 35-40K. In addition, it shows clear evidence of tunnelling type two-level-systems (as in glasses) which show up in noise measurements below 30K.Comment: 11 pages, 4 figures, to appear in Phys Rev B, vol 58, 1st Dec issu

    Low-frequency Current Fluctuations in Individual Semiconducting Single-Wall Carbon Nanotubes

    Get PDF
    We present a systematic study on low-frequency current fluctuations of nano-devices consisting of one single semiconducting nanotube, which exhibit significant 1/f-type noise. By examining devices with different switching mechanisms, carrier types (electrons vs. holes), and channel lengths, we show that the 1/f fluctuation level in semiconducting nanotubes is correlated to the total number of transport carriers present in the system. However, the 1/f noise level per carrier is not larger than that of most bulk conventional semiconductors, e.g. Si. The pronounced noise level observed in nanotube devices simply reflects on the small number of carriers involved in transport. These results not only provide the basis to quantify the noise behavior in a one-dimensional transport system, but also suggest a valuable way to characterize low-dimensional nanostructures based on the 1/f fluctuation phenomenon

    Long-range potential fluctuations and 1/f noise in hydrogenated amorphous silicon

    Full text link
    We present a microscopic theory of the low-frequency voltage noise (known as "1/f" noise) in micrometer-thick films of hydrogenated amorphous silicon. This theory traces the noise back to the long-range fluctuations of the Coulomb potential produced by deep defects, thereby predicting the absolute noise intensity as a function of the distribution of defect activation energies. The predictions of this theory are in very good agreement with our own experiments in terms of both the absolute intensity and the temperature dependence of the noise spectra.Comment: 8 pages, 3 figures, several new parts and one new figure are added, but no conceptual revision

    Preclinical PET imaging of bispecific antibody ERY974 targeting CD3 and glypican 3 reveals that tumor uptake correlates to T cell infiltrate

    Get PDF
    BACKGROUND: Bispecific antibodies redirecting T cells to the tumor obtain increasing interest as potential cancer immunotherapy. ERY974, a full-length bispecific antibody targeting CD3ε on T cells and glypican 3 (GPC3) on tumors, has been in clinical development However, information on the influence of T cells on biodistribution of bispecific antibodies, like ERY974, is scarce. Here, we report the biodistribution and tumor targeting of zirconium-89 (89Zr) labeled ERY974 in mouse models using immuno-positron emission tomography (PET) imaging. METHODS: To study both the role of GPC3 and CD3 on the biodistribution of [89Zr]Zr-N-suc-Df-ERY974, 89Zr-labeled control antibodies targeting CD3 and non-mammalian protein keyhole limpet hemocyanin (KLH) or KLH only were used. GPC3 dependent tumor targeting of [89Zr]Zr-N-suc-Df-ERY974 was tested in xenograft models with different levels of GPC3 expression. In addition, CD3 influence on biodistribution of [89Zr]Zr-N-suc-Df-ERY974 was evaluated by comparing biodistribution between tumor-bearing immunodeficient mice and mice reconstituted with human immune cells using microPET imaging and ex vivo biodistribution. Ex vivo autoradiography was used to study deep tissue distribution. RESULTS: In tumor-bearing immunodeficient mice, [89Zr]Zr-N-suc-Df-ERY974 tumor uptake was GPC3 dependent and specific over [89Zr]Zr-N-suc-Df-KLH/CD3 and [89Zr]Zr-N-suc-Df-KLH/KLH. In mice engrafted with human immune cells, [89Zr]Zr-N-suc-Df-ERY974 specific tumor uptake was higher than in immunodeficient mice. Ex vivo autoradiography demonstrated a preferential distribution of [89Zr]Zr-N-suc-Df-ERY974 to T cell rich tumor tissue. Next to tumor, highest specific [89Zr]Zr-N-suc-Df-ERY974 uptake was observed in spleen and lymph nodes. CONCLUSION: [89Zr]Zr-N-suc-Df-ERY974 can potentially be used to study ERY974 biodistribution in patients to support drug development

    Strong Suppression of Electrical Noise in Bilayer Graphene Nano Devices

    Full text link
    Low-frequency 1/f noise is ubiquitous, and dominates the signal-to-noise performance in nanodevices. Here we investigate the noise characteristics of single-layer and bilayer graphene nano-devices, and uncover an unexpected 1/f noise behavior for bilayer devices. Graphene is a single layer of graphite, where carbon atoms form a 2D honeycomb lattice. Despite the similar composition, bilayer graphene (two graphene monolayers stacked in the natural graphite order) is a distinct 2D system with a different band structure and electrical properties. In graphene monolayers, the 1/f noise is found to follow Hooge's empirical relation with a noise parameter comparable to that of bulk semiconductors. However, this 1/f noise is strongly suppressed in bilayer graphene devices, and exhibits an unusual dependence on the carrier density, different from most other materials. The unexpected noise behavior in graphene bilayers is associated with its unique band structure that varies with the charge distribution among the two layers, resulting in an effective screening of potential fluctuations due to external impurity charges. The findings here point to exciting opportunities for graphene bilayers in low-noise applications
    • …
    corecore