1,625 research outputs found

    Clinical Outcomes and Cataract Formation Rates in Eyes 10 Years After Posterior Phakic Lens Implantation for Myopia.

    Get PDF
    Intraocular collamer lenses (ICLs) are posterior chamber phakic lenses that provide a refractive surgery option for those with high myopia or astigmatism. The short-term and midterm results indicate good refraction stability, efficacy, and safety. Cataract has been suggested to be an important long-term complication of ICL implantation. To report the rates of cataract development and refractive outcomes 10 years after ICL implantation. The study included 133 eyes of 78 patients undergoing consecutive V4 model ICL implantations, which took place from January 1, 1998, through December 31, 2004, at Jules-Gonin Eye Hospital, Lausanne, Switzerland. Data analysis was performed from January 1, 2014, to May 31, 2014. The lenses implanted were as follows: 53 V4 model ICLs of -15.5 D or greater, 73 V4 model ICLs of less than -15.5 diopter (D), and 7 V4 model toric ICLs for myopia. Rate of cataract surgery, lens opacity, ocular hypertension, refractive safety, predictability, and stability. A total of 133 eyes of 78 patients (34 men and 44 women, with a mean [SD] age of 38.8 [9.2] years at enrollment) met the inclusion criteria. The rate of lens opacity development was 40.9% (95% CI, 32.7%-48.8%) and 54.8% (95% CI, 44.7%-63.0%) at 5 and 10 years, respectively. Phacoemulsification was performed in 5 eyes (4.9%; 95% CI, 1.0%-8.7%) and 18 eyes (18.3%; 95% CI, 10.1%-25.8%) at 5 and 10 years after ICL implantation, respectively. The vault height (distance between the posterior ICL surface and anterior lens surface) measured a mean (SD) of 426 (344) μm immediately postoperatively, decreasing to 213 (169) μm at 10 years. A smaller vault height was associated with the development of lens opacity and phacoemulsification (P = .005 and .008, respectively). The intraocular pressure was 15 mm Hg postoperatively, and there was no significant increase in intraocular pressure observed until the 10-year follow-up (16 mm Hg, P = .02). At 10 years, 12 eyes (12.9%; 95% CI, 5.6%-19.6%) had developed ocular hypertension that required topical medication. At 10 years, the mean (SD) safety index was 1.25 (0.57), with a manifest spherical equivalent of -0.5 D at 1-year postoperatively vs -0.7 D at 10 years postoperatively in eyes aimed at emmetropia. This retrospective single center study indicates that ICL implantation provides good long-term safety and stability of refraction in patients with high myopia compared with similar short-term studies. However, the rates of cataract formation and ocular hypertension at 10 years have important clinical implications, and as such this information should be part of the available patient information before ICL implantation

    Electromagnetic Calorimeter for HADES

    Full text link
    We propose to build the Electromagnetic calorimeter for the HADES di-lepton spectrometer. It will enable to measure the data on neutral meson production from nucleus-nucleus collisions, which are essential for interpretation of dilepton data, but are unknown in the energy range of planned experiments (2-10 GeV per nucleon). The calorimeter will improve the electron-hadron separation, and will be used for detection of photons from strange resonances in elementary and HI reactions. Detailed description of the detector layout, the support structure, the electronic readout and its performance studied via Monte Carlo simulations and series of dedicated test experiments is presented. The device will cover the total area of about 8 m^2 at polar angles between 12 and 45 degrees with almost full azimuthal coverage. The photon and electron energy resolution achieved in test experiments amounts to 5-6%/sqrt(E[GeV]) which is sufficient for the eta meson reconstruction with S/B ratio of 0.4% in Ni+Ni collisions at 8 AGeV. A purity of the identified leptons after the hadron rejection, resulting from simulations based on the test measurements, is better than 80% at momenta above 500 MeV/c, where time-of-flight cannot be used.Comment: 40 pages, 38 figures version2 - the time schedule added, information about PMTs in Sec.III update
    corecore