44 research outputs found

    Lack of influence of the COX inhibitors metamizol and diclofenac on platelet GPIIb/IIIa and P-selectin expression in vitro

    Get PDF
    BACKGROUND: The effect of non-steroidal anti-inflammatory drugs (NSAIDs) for reduced platelet aggregation and thromboxane A(2 )synthesis has been well documented. However, the influence on platelet function is not fully explained. Aim of this study was to examine the influence of the COX-1 inhibiting NSAIDs, diclofenac and metamizol on platelet activation and leukocyte-platelet complexes, in vitro. Surface expression of GPIIb/IIIa and P-selectin on platelets, and the percentage of platelet-leukocyte complexes were investigated. METHODS: Whole blood was incubated with three different concentrations of diclofenac and metamizol for 5 and 30 minutes, followed by activation with TRAP-6 and ADP. Rates of GPIIb/IIIa and P-selectin expression, and the percentage of platelet-leukocyte complexes were analyzed by a flow-cytometric assay. RESULTS: There were no significant differences in the expression of GPIIb/IIIa and P-selectin, and in the formation of platelet-leukocyte complexes after activation with ADP and TRAP-6, regarding both the time of incubation and the concentrations of diclofenac and metamizol. CONCLUSIONS: Accordingly, the inhibitory effect of diclofenac and metamizol on platelet aggregation is not related to a reduced surface expression of P-selectin and GPIIb/IIIa on platelets

    Augmented instructions : analysis of performance and efficiency of assembly tasks

    Get PDF
    Augmented Reality (AR) technology makes it possible to present information in the user’s line of sight, right at the point of use. This brings the capability to visualise complex information for industrial maintenance applications in an effective manner, which typically rely on paper instructions and tacit knowledge developed over time. Existing research in AR instruction manuals has already shown its potential to reduce the time taken to complete assembly tasks, as well as improving accuracy [1–3]. In this study, the outcomes of several aspects of AR instructions are explored and their effects on the chosen Key Performance Indicators (KPIs) of task completion time, error rate, cognitive effort and usability are assessed. A standardised AR assembly task is also described for performance comparison, and a novel AR experimental tool is presented, which takes advantage of the flexibility of internet connected peripherals, to explore various different aspects of AR app design to isolate their effects. Results of the experiments are given here, providing insight into the most effective way of delivering information and promoting interaction between user and computer, in terms of user performance and acceptance

    Engineered nanomaterials: toward effective safety management in research laboratories

    Get PDF
    It is still unknown which types of nanomaterials and associated doses represent an actual danger to humans and environment. Meanwhile, there is consensus on applying the precautionary principle to these novel materials until more information is available. To deal with the rapid evolution of research, including the fast turnover of collaborators, a user-friendly and easy-to-apply risk assessment tool offering adequate preventive and protective measures has to be provided.Results: Based on new information concerning the hazards of engineered nanomaterials, we improved a previously developed risk assessment tool by following a simple scheme to gain in efficiency. In the first step, using a logical decision tree, one of the three hazard levels, from H1 to H3, is assigned to the nanomaterial. Using a combination of decision trees and matrices, the second step links the hazard with the emission and exposure potential to assign one of the three nanorisk levels (Nano 3 highest risk; Nano 1 lowest risk) to the activity. These operations are repeated at each process step, leading to the laboratory classification. The third step provides detailed preventive and protective measures for the determined level of nanorisk.Conclusions: We developed an adapted simple and intuitive method for nanomaterial risk management in research laboratories. It allows classifying the nanoactivities into three levels, additionally proposing concrete preventive and protective measures and associated actions. This method is a valuable tool for all the participants in nanomaterial safety. The users experience an essential learning opportunity and increase their safety awareness. Laboratory managers have a reliable tool to obtain an overview of the operations involving nanomaterials in their laboratories; this is essential, as they are responsible for the employee safety, but are sometimes unaware of the works performed. Bringing this risk to a three-band scale (like other types of risks such as biological, radiation, chemical, etc.) facilitates the management for occupational health and safety specialists. Institutes and school managers can obtain the necessary information to implement an adequate safety management system. Having an easy-to-use tool enables a dialog between all these partners, whose semantic and priorities in terms of safety are often different

    Systemic immune-inflammation index (SII) and neutrophil to lymphocyte ratio (NLR) are useful markers for assessing effects of anti-inflammatory diet in patients before coronary artery bypass grafting

    No full text
    Background. One of the risk factors responsible for coronary artery disease (CAD) is an inadequate diet that is frequently deficient in anti-inflammatory components, such as polyphenols and omega-3 fatty acids. The neutrophil to lymphocyte ratio (NLR) and the systemic immune-inflammation index (SII) are inflammatory markers that may reflect a diet’s anti- inflammatory potential. Objective. The aim of this study was to evaluate the effects that CAD patients’ nutrition patterns have on NLR and SII. Material and methods. A retrospective study assessed the dietary habits and inflammatory marker levels in patients with advanced CAD before they underwent coronary artery bypass grafting (CABG) (n=101). Patients were divided into subgroups based on their NLR and SII levels. Results. Subgroups with lower NLR and SII levels had consumed significantly more eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) (p=0.02). The group with alower ratio of omega-6 to omega-3 fatty acids (<4:1) also had lower NLR and SII levels (p=0.007 and p=0.01, respectively). Statistically significant negative correlations were found between EPA and DHA, as well as omega-3 intake, and both NLR and SII values. No statistically significant differences were found between the subgroups with lower and higher NLR and SII values for polyphenol intakes. Conclusions. Inflammatory markers such as NLR and SII may reflect an anti-inflammatory diet consumed by cardiac patients. A simultaneous assessment of dietary habits and inflammatory parameters is beneficial in the possible prevention of adverse cardiovascular incidents after CABG. There is also a need to establish reference values for SII and NL

    A sharp-switching gateless device (Z3-FET) in advanced FDSOI technology

    No full text
    session 9: Advanced Devices ad Three-Dimensional IntegrationInternational audienceA systematic study of a novel band modulation device (Z3-FET: Zero gate, Zero swing slope and Zero impact ionization) fabricated in most advanced Fully Depleted Silicon-On-Insulator technology is presented. Since the device has no front gate, the operation mechanism is controlled by two buried ground planes. Characteristics such as sharp switching, low leakage, and controllable triggering are measured and discussed. We explore several variants (thin and thick silicon film) and show promising results in terms of high current and switching performance
    corecore