99 research outputs found

    Water bottle flipping physics

    Get PDF
    The water bottle flipping challenge consists of spinning a bottle, partially filled with water, and making it land upright. It is quite a striking phenomenon, since at first sight, it appears rather improbable that a tall rotating bottle could make such a stable landing. Here, we analyze the physics behind the water bottle flip, based on experiments and an analytical model that can be used in the classroom. Our measurements show that the angular velocity of the bottle decreases dramatically, enabling a nearly vertical descent and a successful landing. The reduced rotation is due to an increase in the moment of inertia, caused by the in-flight redistribution of the water mass along the bottle. Experimental and analytical results are compared quantitatively, and we demonstrate how to optimize the chances for a successful landing.</p

    Osteoimmunomodulatory GelMA/liposome coatings to promote bone regeneration of orthopedic implants

    Get PDF
    Despite being the most widely used biomaterials in orthopedic surgery, metallic implants do not induce new bone growth because they are bioinert. Surface biofunctionalization of implants with immunomodulatory mediators is a recent approach to promote osteogenic factors that facilitate bone regeneration. Liposomes (Lip) can be used as a low-cost, efficient and simple immunomodulator to stimulate immune cells in favor of bone regeneration. Even though liposomal coating systems have been reported previously, their main disadvantage is their limited ability to preserve liposome integrity after drying. In order to address this issue, we developed a hybrid system in which liposomes could be embedded in a polymeric hydrogel namely gelatin methacryloyl (GelMA). Specifically, we have developed a novel versatile coating strategy using electrospray technology to coat implants with GelMA/Liposome without using adhesive intermediate layer. The two differently charged Lip (i.e., anionic and cationic) were blended with GelMA and coated via electrospray technology on the bone-implant surfaces. The results showed that the developed coating withstood mechanical stress during surgical replacement, and Lip inside GelMA coating stayed intact in different storage conditions for a minimum of 4 weeks. Surprisingly, bare Lip, either cationic or anionic, improved the osteogenesis of human Mesenchymal Stem Cells (MSCs) by inducing pro-inflammatory cytokines, even at a low dosage of Lip released from the GelMA coating. More importantly, we showed that the inflammatory response could be fine-tuned by selecting the Lip concentration, Lip/hydrogel ratio, and coating thickness to determine the timing of the release such that we can accommodate different clinical needs. These promising results pave the way to use these Lip coatings to load different types of therapeutic cargo for bone-implant applications

    Osteoimmunomodulatory GelMA/liposome coatings to promote bone regeneration of orthopedic implants

    Get PDF
    Despite being the most widely used biomaterials in orthopedic surgery, metallic implants do not induce new bone growth because they are bioinert. Surface biofunctionalization of implants with immunomodulatory mediators is a recent approach to promote osteogenic factors that facilitate bone regeneration. Liposomes (Lip) can be used as a low-cost, efficient and simple immunomodulator to stimulate immune cells in favor of bone regeneration. Even though liposomal coating systems have been reported previously, their main disadvantage is their limited ability to preserve liposome integrity after drying. In order to address this issue, we developed a hybrid system in which liposomes could be embedded in a polymeric hydrogel namely gelatin methacryloyl (GelMA). Specifically, we have developed a novel versatile coating strategy using electrospray technology to coat implants with GelMA/Liposome without using adhesive intermediate layer. The two differently charged Lip (i.e., anionic and cationic) were blended with GelMA and coated via electrospray technology on the bone-implant surfaces. The results showed that the developed coating withstood mechanical stress during surgical replacement, and Lip inside GelMA coating stayed intact in different storage conditions for a minimum of 4 weeks. Surprisingly, bare Lip, either cationic or anionic, improved the osteogenesis of human Mesenchymal Stem Cells (MSCs) by inducing pro-inflammatory cytokines, even at a low dosage of Lip released from the GelMA coating. More importantly, we showed that the inflammatory response could be fine-tuned by selecting the Lip concentration, Lip/hydrogel ratio, and coating thickness to determine the timing of the release such that we can accommodate different clinical needs. These promising results pave the way to use these Lip coatings to load different types of therapeutic cargo for bone-implant applications

    SOS: A Screening Instrument to Identify Children with Handwriting Impairments

    Get PDF
    Poor handwriting has been shown to be associated with developmental disorders such as Developmental Coordination Disorder, Attention Deficit Hyperactivity Disorder, autism, and learning disorders. Handwriting difficulties could lead to academic underachievement and poor self-esteem. Therapeutic intervention has been shown to be effective in treating children with poor handwriting, making early identification critical. The SOS test (Systematic Screening for Handwriting Difficulties) has been developed for this purpose. A child copies a sample of writing within 5 min. Handwriting quality is evaluated using six criteria and writing speed is measured. The Dutch SOS test was administered to 860 Flemish children (7-12 years). Inter-and intrarater reliability was excellent. Test-retest reliability was moderate. A correlation coefficient of 0.70 between SOS and "Concise Assessment Methods of Children Handwriting" test (Dutch version) confirmed convergent validity. The SOS allowed discrimination between typically developing children and children in special education, males and females, and different age groups

    Is there a difference between child self-ratings and parent proxy-ratings of the quality of life of children with a diagnosis of Attention Deficit Hyperactivity Disorder (ADHD)? A systematic review of the literature

    Get PDF
    There are contemporary indicators that parent proxy-ratings and child self-ratings of a child’s quality of life (QoL) are not interchangeable. This review examines dual informant studies to assess parent–child agreement on the QoL of children with attention-deficit/hyperactivity disorder. A systematic search of four major databases (PsycINFO, MEDLINE, EMBASE and Cochrane databases) was completed, and related peer-reviewed journals were hand-searched. Studies which reported quantitative QoL ratings for matched parent and child dyads were screened in accordance with relevant inclusion and exclusion criteria. Key findings were extracted from thirteen relevant studies, which were rated for conformity to the recommendations of an adapted version of the STROBE statement guidelines for observational studies. In the majority of studies reviewed, children rated their QoL more highly than their parents. There was some evidence for greater agreement on the physical health domain than psychosocial domains

    Does switching from oral extended-release methylphenidate to the methylphenidate transdermal system affect health-related quality-of-life and medication satisfaction for children with attention-deficit/hyperactivity disorder?

    Get PDF
    Background: To evaluate health-related quality of life (HRQL) and medication satisfaction after switching from a stable dose of oral extended-release methylphenidate (ER-MPH) to methylphenidate transdermal system (MTS) via a dose-transition schedule in children with attention-deficit/hyperactivity disorder (ADHD). Methods: In a 4-week, multisite, open-label study, 171 children (164 in the intent-to-treat [ITT] population) aged 6-12 years diagnosed with ADHD abruptly switched from a stable dose of oral ER-MPH to MTS nominal dosages of 10, 15, 20, and 30 mg using a predefined dose-transition schedule. Subjects remained on the scheduled dose for the first week, after which the dose was then titrated to an optimal effect. The ADHD Impact Module-Children (AIM-C), a disease-specific validated HRQL survey instrument measuring child and family impact, was used to assess the impact of ADHD symptoms on the lives of children and their families at baseline and study endpoint. Satisfaction with MTS use was assessed via a Medication Satisfaction Survey (MSS) at study endpoint. Both the AIM-C and MSS were completed by a caregiver (parent/legally authorized representative). Tolerability was monitored by spontaneous adverse event (AE) reporting. Results: AIM-C child and family HRQL mean scores were above the median possible score at baseline and were further improved at endpoint across all MTS doses. Similar improvements were noted for behavior, missed doses, worry, and economic impact AIM-C item scores. Overall, 93.8% of caregivers indicated a high level of satisfaction with their child's use of the study medication. The majority of treatment-emergent AEs (> 98%) were mild to moderate in intensity, and the most commonly reported AEs included headache, decreased appetite, insomnia, and abdominal pain. Seven subjects discontinued the study due to intolerable AEs (n = 3) and application site reactions (n = 4). Conclusion: This study demonstrates that MTS, when carefully titrated to optimal dose, may further improve child and family HRQL, as well as behavioral, medication worry, and economic impact item scores, as measured by the AIM-C in subjects switching to MTS from a stable dose of routinely prescribed oral ER-MPH after a short treatment period. Furthermore, following the abrupt conversion from oral ER-MPH to MTS, the majority of caregivers reported being highly satisfied with MTS as a treatment option for their children with ADHD. Trial Registration: NCT0015198
    • …
    corecore