464 research outputs found

    Broadband noise decoherence in solid-state complex architectures

    Full text link
    Broadband noise represents a severe limitation towards the implementation of a solid-state quantum information processor. Considering common spectral forms, we propose a classification of noise sources based on the effects produced instead of on their microscopic origin. We illustrate a multi-stage approach to broadband noise which systematically includes only the relevant information on the environment, out of the huge parametrization needed for a microscopic description. We apply this technique to a solid-state two-qubit gate in a fixed coupling implementation scheme.Comment: Proceedings of Nobel Symposium 141: Qubits for Future Quantum Informatio

    Decoherence times of universal two-qubit gates in the presence of broad-band noise

    Full text link
    The controlled generation of entangled states of two quantum bits is a fundamental step toward the implementation of a quantum information processor. In nano-devices this operation is counteracted by the solid-state environment, characterized by a broadband and non-monotonic power spectrum, often 1/f at low frequencies. For single-qubit gates, incoherent processes due to fluctuations acting on different time scales result in peculiar short- and long-time behavior. Markovian noise gives rise to exponential decay with relaxation and decoherence times, T1 and T2, simply related to the symmetry of the qubit-environment coupling Hamiltonian. Noise with the 1/f power spectrum at low frequencies is instead responsible for defocusing processes and algebraic short-time behavior. In this paper, we identify the relevant decoherence times of an entangling operation due to the different decoherence channels originating from solid-state noise. Entanglement is quantified by concurrence, which we evaluate in an analytic form employing a multi-stage approach. The 'optimal' operating conditions of reduced sensitivity to noise sources are identified. We apply this analysis to a superconducting \sqrt{i-SWAP} gate for experimental noise spectra.Comment: 35 pages, 11 figure

    Effects of low-frequency noise cross-correlations in coupled superconducting qubits

    Full text link
    We study the effects of correlated low frequency noise sources acting on a two qubit gate in a fixed coupling scheme. A phenomenological model for the spatial and cross-talk correlations is introduced. The decoherence inside the SWAP subspace is analysed by combining analytic results based on the adiabatic approximation and numerical simulations. Results critically depend on amplitude of the low frequency noise with respect to the qubits coupling strength. Correlations between noise sources induce qualitative different behaviors depending on the values of the above parameters. The possibility to reduce dephasing due to correlated low frequency noise by a recalibration protocol is discussed.Comment: 18 pages, 7 figure

    Design of a novel LOX-1 receptor antagonist mimicking the natural substrate

    Get PDF
    The lectin-like oxidized low-density lipoprotein receptor-1 (LOX-1), the major receptor for oxidized low-density lipoprotein (ox-LDL) in endothelial cells, is overexpressed in atherosclerotic lesions. LOX-1 specific inhibitors, urgently necessary to reduce the rate of atherosclerotic and inflammation processes, are not yet available. We have designed and synthesized a new modified oxidized phospholipid, named PLAzPC, which plays to small scale the ligand-receptor recognition scheme. Molecular docking simulations confirm that PLAzPC disables the hydrophobic component of the ox-LDL recognition domain and allows the interaction of the l-lysine backbone charged groups with the solvent and with the charged/polar residues located around the edges of the LOX-1 hydrophobic tunnel. Binding assays, in a cell model system expressing human LOX-1 receptors, confirm that PLAzPC markedly inhibits ox-LDL binding to LOX-1 with higher efficacy compared to previously identified inhibitors

    Prognostication after cardiac arrest

    Get PDF
    Hypoxic-ischaemic brain injury (HIBI) is the main cause of death in patients who are comatose after resuscitation from cardiac arrest. A poor neurological outcome-defined as death from neurological cause, persistent vegetative state, or severe neurological disability-can be predicted in these patients by assessing the severity of HIBI. The most commonly used indicators of severe HIBI include bilateral absence of corneal and pupillary reflexes, bilateral absence of N 2 O waves of short-latency somatosensory evoked potentials, high blood concentrations of neuron specific enolase, unfavourable patterns on electroencephalogram, and signs of diffuse HIBI on computed tomography or magnetic resonance imaging of the brain. Current guidelines recommend performing prognostication no earlier than 72 h after return of spontaneous circulation in all comatose patients with an absent or extensor motor response to pain, after having excluded confounders such as residual sedation that may interfere with clinical examination. A multimodal approach combining multiple prognostication tests is recommended so that the risk of a falsely pessimistic prediction is minimised

    Angular analysis of bremsstrahlung in alpha decay

    Full text link
    A new quantum electrodynamical method of calculations of bremsstrahlung spectra in the α\alpha-decay of heavy nuclei taking into account the angle between the directions of α\alpha-particle motion (or its tunneling) and photon emission is presented. The angular bremsstrahlung spectra for 210Po^{210}{Po} have been obtained for the first time. According to calculations, the bremsstrahlung in the α\alpha-decay of this nucleus depends extremely weakly on the angle. Taking into account nuclear forces, such dependence is not changed visibly. An analytical formula of the angular dependence of the bremsstrahlung spectra is proposed and gives its harmonic behavior. The extremal values of the angle, at which the bremsstrahlung has maximal and minimal values, has been found.Comment: 15 pages, 1 file of figure in EPS format, LaTeX v.2e with EPJ style. In the new variant of the paper: 1) more attention is given to a convergence problem of computer calculations of the bremsstrahlung spectra; 2) a new section with inclusion of Woods-Saxon component in construction of the total realistic α\alpha-nucleus potential into our model (with our first brermsstrahlung spectra for 210Po^{210}{Po} at such potential) is included into the paper; 3) possible ways of further improvement of the quantum-mechanical models are pointed ou

    Using the latest resistance score to predict etravirine (ETV) resistance in naĂŻve and NNRTI-failing patients

    Get PDF
    Methods A set of 17 mutations (V90I, A98G, L100I, K101E/H/P, V106I, E138A, V179D/F/T, Y181C/I/V, G190A/S, M230L) were found associated with ETV resistance in the Phase III DUET-1 and DUET-2 trials. Recently, a different score was assigned to each mutation (i.e. Y181C/I have the highest score: 3). An overall score of ≤4 was associated with reduced response and a score between 2.5–3.5 with intermediate response (reference). ETV resistance was calculated from a large database of patients undergoing genotypic resistance test

    A Concept for an STJ-based Spectrograph

    Full text link
    We describe a multi-order spectrograph concept suitable for 8m-class telescopes, using the intrinsic spectral resolution of Superconducting Tunneling Junction detectors to sort the spectral orders. The spectrograph works at low orders, 1-5 or 1-6, and provides spectral coverage with a resolving power of R~8000 from the atmospheric cutoff at 320 nm to the long wavelength end of the infrared H or K band at 1800 nm or 2400 nm. We calculate that the spectrograph would provide substantial throughput and wavelength coverage, together with high time resolution and sufficient dynamic range. The concept uses currently available technology, or technologies with short development horizons, restricting the spatial sampling to two linear arrays; however an upgrade path to provide more spatial sampling is identified. All of the other challenging aspects of the concept - the cryogenics, thermal baffling and magnetic field biasing - are identified as being feasible.Comment: Accepted in Monthly Notices of the Royal Astronomical Society, 12 pages with 10 figure
    • …
    corecore