23,214 research outputs found

    High-frequency high-voltage high-power DC-to-DC converters

    Get PDF
    The current and voltage waveshapes associated with the power transitor and the power diode in an example current-or-voltage step-up (buck-boost) converter were analyzed to highlight the problems and possible tradeoffs involved in the design of high voltage high power converters operating at switching frequencies in the range of 100 Khz. Although the fast switching speeds of currently available power diodes and transistors permit converter operation at high switching frequencies, the resulting time rates of changes of current coupled with parasitic inductances in series with the semiconductor switches, produce large repetitive voltage transients across the semiconductor switches, potentially far in excess of the device voltage ratings. The need is established for semiconductor switch protection circuitry to control the peak voltages appearing across the semiconductor switches, as well as to provide the waveshaping action require for a given semiconductor device. The possible tradeoffs, as well as the factors affecting the tradeoffs that must be considered in order to maximize the efficiency of the converters are enumerated

    Analysis of transistor and snubber turn-off dynamics in high-frequency high-voltage high-power converters

    Get PDF
    Dc to dc converters which operate reliably and efficiently at switching frequencies high enough to effect substantial reductions in the size and weight of converter energy storage elements are studied. A two winding current or voltage stepup (buck boost) dc-to-dc converter power stage submodule designed to operate in the 2.5-kW range, with an input voltage range of 110 to 180 V dc, and an output voltage of 250 V dc is emphasized. In order to assess the limitations of present day component and circuit technologies, a design goal switching frequency of 10 kHz was maintained. The converter design requirements represent a unique combination of high frequency, high voltage, and high power operation. The turn off dynamics of the primary circuit power switching transistor and its associated turn off snubber circuitry are investigated

    Mathematical analysis of a model for the growth of the bovine corpus luteum

    Get PDF
    The corpus luteum (CL) is an ovarian tissue that grows in the wound space created by follicular rupture. It produces the progesterone needed in the uterus to maintain pregnancy. Rapid growth of the CL and progesterone transport to the uterus require angiogenesis, the creation of new blood vessels from pre-existing ones, a process which is regulated by proteins that include fibroblast growth factor 2 (FGF2).\ud \ud In this paper we develop a system of time-dependent ordinary differential equations to model CL growth. The dependent variables represent FGF2, endothelial cells (ECs), luteal cells, and stromal cells (like pericytes), by assuming that the CL volume is a continuum of the three cell types. We assume that if the CL volume exceeds that of the ovulated follicle, then growth is inhibited. This threshold volume partitions the system dynamics into two regimes, so that the model may be classified as a Filippov (piecewise smooth) system.\ud \ud We show that normal CL growth requires an appropriate balance between the growth rates of luteal and stromal cells. We investigate how angiogenesis influences CL growth by considering how the system dynamics depend on the dimensionless EC proliferation rate, p5. We find that weak (low p5) or strong (high p5) angiogenesis leads to ‘pathological’ CL growth, since the loss of CL constituents compromises progesterone production or delivery. However, for intermediate values of p5, normal CL growth is predicted. The implications of these results for cow fertility are also discussed. For example, inadequate angiogenesis has been linked to infertility in dairy cows

    Non-Newtonian and flow pulsatility effects in simulation models of a stented intracranial aneurysm

    Get PDF
    Permission to redistribute provided by publishers.Three models of different stent designs implanted in a cerebral aneurysm, originating from the Virtual Intracranial Stenting Challenge'07, are meshed and the flow characteristics simulated using commercial computational fluid dynamics (CFD) software in order to investigate the effects of non-Newtonian viscosity and pulsatile flow. Conventional mass inflow and wall shear stress (WSS) output are used as a means of comparing the cfd simulations. In addition, a WSS distribution is presented, which clearly discriminates in favour of the stent design identified by other groups. It is concluded that non-Newtonian and pulsatile effects are important to include in order to avoid underestimating wss, to understand dynamic flow effects, and to discriminate more effectively between stent designs. © Authors 2011

    A dc model for power switching transistors suitable for computer-aided design and analysis

    Get PDF
    A model for bipolar junction power switching transistors whose parameters can be readily obtained by the circuit design engineer, and which can be conveniently incorporated into standard computer-based circuit analysis programs is presented. This formulation results from measurements which may be made with standard laboratory equipment. Measurement procedures, as well as a comparison between actual and computed results, are presented

    A Comprehensive Radio and Optical Study of Abell 2256: Activity from an Infalling Group

    Get PDF
    Abell 2256 is a nearby (z~0.06), rich cluster of galaxies with fascinating observed properties across a range of wavelengths. Long believed to represent a cluster merger, recent X-ray and optical results have suggested that in addition to the primary cluster and subcluster there is evidence for a third, poorer system. We present wide-field, high sensitivity 1.4 GHz VLA radio observations of Abell 2256 in conjunction with optical imaging and additional spectroscopy. Over 40 cluster radio galaxies are identified, with optical spectroscopy indicating the emission source (star formation or AGN) for most of them. While the overall fraction of galaxies exhibiting radio emission is consistent with a large sample of other nearby clusters, we find an increase in the activity level of galaxies belonging to the third system (hereafter, the ``Group''). Specifically, the Group has relatively more star formation than both the primary cluster and main subcluster. The position of the Group is also coincident with the observed cluster radio relic. We suggest that the Group recently (~0.3 Gyr) merged with the primary cluster and that this merger, not the ongoing merger of the primary and the main subcluster, might be responsible for many of the unusual radio properties of Abell 2256. Furthermore, the greater star formation activity of the Group suggests that the infall of groups is an important driver of galaxy evolution in clusters.Comment: 21 pages plus 13 JPEG figures; to appear in the Astronomical Journa

    Deep retrofit approaches: managing risks to minimise the energy performance gap

    Get PDF
    Energy use in buildings remains a significant part of overall energy demand. Deep renovation projects, delivered at scale, remain a challenging task to achieve a lower carbon building stock.The complexity of building renovation beyond standards and building specifications is related to inherent characteristics of buildings which require distinct project management techniques. While there are now more projects focusing on achieving operational performance, there is still very little research on the management of the renovation and retrofit process itself. Recognising that each project working on an existing building is unique in type, timing, energy goals and the roles/characteristics of people involved, the aim of this paper is to add to the current debate of how intervention approaches (one-off or over-time, whole-house, fabric-first room-by-room, measure-by-measure) are promoted by different policies, and with what impact. The paper discusses the complexity of a deep renovation project in terms of planning and management and the ways current policies can lead to unintended consequences in the short and long term, as well in lock-in effects that contribute to energy performance, and to the gap between designed and actual energy performance. Using a typology of risks, the issues associated with renovation processes and technologies were explored in a sample of cases studies from deep retrofits across the EU. The evidence from these shows that despite holistic planning for renovation, interventions tend to be carried out in phases. These contrasting time dimensions and the different retrofit approaches are discussed with risk profiles for each retrofit project, suggesting how risks emerge throughout a project. A series of risk mitigation strategies are suggested which, taken in combination to suit a specific project’s risk profile, may serve to reduce and potentially eliminate the building renovation energy performance gap

    Technical Note: Field experiences using UV/VIS sensors for high-resolution monitoring of nitrate in groundwater

    Get PDF
    peer-reviewedTwo different in situ spectrophotometers are compared that were used in the field to determine nitrate-nitrogen (NO3-N) concentrations at two distinct spring discharge sites. One sensor was a double wavelength spectrophotometer (DWS) and the other a multiple wavelength spectrophotometer (MWS). The objective of the study was to review the hardware options, determine ease of calibration, accuracy, influence of additional substances and to assess positive and negative aspects of the two sensors as well as troubleshooting and trade-offs. Both sensors are sufficient to monitor highly time-resolved NO3-N concentrations in emergent groundwater. However, the chosen path length of the sensors had a significant influence on the sensitivity and the range of detectable NO3-N. The accuracy of the calculated NO3-N concentrations of the sensors can be affected if the content of additional substances such as turbidity, organic matter, nitrite or hydrogen carbonate significantly varies after the sensors have been calibrated to a particular water matrix. The MWS offers more possibilities for calibration and error detection but requires more expertise compared with the DWS.The authors would like to acknowledge the Teagasc Walsh Fellowship scheme for funding the study in Ireland, and the German federal Ministry of Education and Research (BMBF) for sponsoring the SMART-project (grant no. 02WM1079-1086, 02WM1211-1212) for the study in Jordan.Teagasc Walsh Fellowship Programm
    corecore