355 research outputs found

    General anesthesia for electroconvulsive therapy with Brugada electrocardiograph pattern

    Get PDF
    Brugada syndrome is characterized by an electrocardiograph pattern of right bundle-branch block and has an increased risk for cardiac arrest due to malignant arrhythmia. We describe the successful anesthetic management for electroconvulsive therapy in a patient with Brugada electrocardiograph pattern. Patients with Brugada ECG pattern are not recommended to use neostigmine which augments ST elevation. Sugammadex was administered as a neuromuscular reversal agent in this case. Sugammadex provides rapid reversal of profound rocuronium-induced neuromuscular blockade under propofol anesthesia

    NK-1 receptor antagonism decreases PONV

    Get PDF
    Purpose : Post-operative nausea and vomiting (PONV) remains the most frequently reported patient complaint after anesthesia. Aprepitant is the first neurokinin-1(NK1) receptor antagonism available for use as an antiemetic. We investigated whether aprepitant can effectively decrease PONV in patients undergoing laparoscopic gynecological surgery. Methods : Sixty four patients receiving general anesthesia for laparoscopic gynecological surgery were randomly assigned to either receive a preoperative dose of 80mg aprepitant or no drug. Efficacy was assessed in 2 and 24 hours after surgery. Primary and secondary endpoints were analyzed for the time intervals 0-2 hours (acute phase) and 2-24 hours (delayed phase). Vomiting, nausea, use of rescue anti-emetic, and visual analog scale (VAS) were assessed. Nausea was assessed on a 4-point scale, from 0 to 3. Results : Sixty patients participated in the study. At acute phase, PONV was present in both control and NK1 group and were 63% and 43% respectively. The severity of nausea was much less in the NK1 group. PONV prevalence at delayed phase was present in control but absent in NK1 group 27% vs. 0%, respectively. The amount of pain medication used by patients in the NK1 group was significantly less for diclofenac and pentazocine suggesting increase pain tolerance. Conclusions : Neurokinin-1 receptor antagonism effectively lowered PONV increased pain tolerance, and expedited recovery in patients undergoing laparoscopic gynecological surgery

    The First Result of Global Commissioning of the ATLAS Endcap Muon Trigger System in ATLAS Cavern

    Get PDF
    We report on the ATLAS commissioning run from the view point of the Thin Gap Chamber (TGC), which is the ATLAS end cap muon trigger detector. All the TGC sectors with on-detector electronics are going to be installed to the ATLAS cavern by the end of September 2007. To integrate all sub-detectors before the physics run starting from early 2008, the global commissioning run together with other sub-detectors has been performed from June 2007. We have evaluated the performance of the complete trigger chain of the TGC electronics and provide the trigger signal using cosmic-ray to the sub-systems in the global run environment

    Final Test at the Surface of the ATLAS Endcap Muon Trigger Chamber Electronics

    Get PDF
    For the detector commissioning planned in 2007, sector assembly of the ATLAS muon-endcap trigger chambers and final test at the surface for the assembled electronics are being done in CERN and almost completed. For the test, we built up the Data Acquisition (DAQ) system using test pulse of two types and cosmic rays in order to check functionality of the various aspects of the electronics mounted on a sector. So far, 99% of all 320,000 channels have been tested and most of them were installed into the ATLAS cavern. In this presentation, we will describe the DAQ systems and mass-test procedure in detail, and report the result of electronics test with some actual experience

    Transmission electron microscopic observations of nanobubbles and their capture of impurities in wastewater

    Get PDF
    Unique properties of micro- and nanobubbles (MNBs), such as a high adsorption of impurities on their surface, are difficult to verify because MNBs are too small to observe directly. We thus used a transmission electron microscope (TEM) with the freeze-fractured replica method to observe oxygen (O2) MNBs in solutions. MNBs in pure water and in 1% NaCl solutions were spherical or oval. Their size distribution estimated from TEM images close to that of the original solution is measured by light-scattered methods. When we applied this technique to the observation of O2 MNBs formed in the wastewater of a sewage plant, we found the characteristic features of spherical MNBs that adsorbed surrounding impurity particles on their surface

    Phase I–II study of irinotecan (CPT-11) plus nedaplatin (254-S) with recombinant human granulocyte colony-stimulating factor support in patients with advanced or recurrent cervical cancer

    Get PDF
    Combination chemotherapy with irinotecan (CPT-11) and platinum compounds is effective for treating cervical cancer. Nedaplatin (254-S) is a new cisplatin analogue that achieves a high response rate (53%) in patients with primary cervical cancer. We performed a phase I–II study of combination chemotherapy with CPT-11 plus 254-S for advanced or recurrent cervical cancer. The inclusion criteria were stage IV disease or recurrence. CPT-11 and 254-S were administered intravenously on day 1, while rhG-CSF (50 μg) was given on days 3–12. This regimen was repeated after 4 weeks. Dose escalation was carried out in tandem (CPT-11/254-S: 50/70, 50/80, and 60/80 mg m−2). A total of 27 patients (stage IV=seven, recurrence=20) were enrolled. The phase I study enrolled eight patients. At dose levels 1 and 2, no dose-limiting toxicities were observed. At dose level 3, the first two patients developed DLTs. The maximum tolerated dose of CPT-11 and 254-S was 60 and 80 mg m−2, respectively, and the recommended doses were 50 and 80 mg m−2. Grade 3/4 haematologic toxicity occurred in 67% in phase II study, but there were no grade 3 nonhaematologic toxicities except fot nausea or lethargy. In all 27 patients, there were two complete responses (7%) and 14 Partial responses (52%), for an overall response rate of 59% (95% confidence interval: 39–78%). Among the 12 responders with recurrent disease, the median time to progression and median survival were 161 days (range: 61–711 days) and 415 days (range: 74–801 days). This new regimen is promising for cervical cancer
    corecore