203 research outputs found

    Smoking fewer than 20 cigarettes per day and remaining abstinent for more than 12 hours reduces carboxyhemoglobin levels in packed red blood cells for transfusion

    Get PDF
    The prevalence of smokers among blood donors and the effect of smoking on the quality of donated blood have not been extensively explored. In the present study, we determined the prevalence of smoker donors in a large blood bank in Southern Brazil and evaluated the quality of packed red blood cells (RBCs) from these donors through recommended quality control tests and measurement of carboxyhemoglobin (COHb) levels. We then assessed the influence of smoking habits and abstinence before donation on these parameters. Material and methods An observational study was conducted to determine the prevalence of smoking donors, while a prospective cohort study compared conventional hematological and serological parameters and COHb levels at 0, 15, and 30 days after donation in RBCs donated by smokers (N = 31) and nonsmokers (N = 31) and their association with smoking habits and abstinence before donation. Results Of 14,428 blood donations received in 1 year, 5.9% were provided by smokers. Storage over time slightly altered some quality parameters, such as hematocrit, hemoglobin, hemolysis, and COHb levels, in RBC packs. COHb levels were higher in RBC packs from smokers (8%) than from non-smokers (2%), and increased as a function of the number of cigarettes smoked daily and time elapsed since the last cigarette smoked before donation. Lower levels were found in RBC packs from donors who smoked fewer than 20 cigarettes per day or remained abstinent for more than 12h before giving blood. Conclusion Although cigarette smoke had no significant effect on blood quality parameters such as hematocrit, hemoglobin, or hemolysis, it quadrupled COHb levels in packed RBCs. Abstinence from smoking for more than 12h or smoking fewer than 20 cigarettes daily helped decrease COHb levels. Implications Given the increasing prevalence of tobacco use worldwide, we suggest blood banks recommend 12h of tobacco abstinence before donation and analyze COHb levels in donated blood as an approach to reduce risk for high-risk recipients

    Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature

    Get PDF
    Joint arthroplasty registries show an increased rate of aseptic loosening in uncemented acetabular components as compared to cemented acetabular components. Since loosening is associated with particulate wear debris, we postulated that uncemented acetabular components demonstrate a higher polyethylene wear rate than cemented acetabular components in total hip arthroplasty. We performed a systematic review of the peer-reviewed literature, comparing the wear rate in uncemented and cemented acetabular components in total hip arthroplasty. Studies were identified using MEDLINE (PubMed), EMBASE and the Cochrane Central Register of Controlled Trials. Study quality was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. The search resulted in 425 papers. After excluding duplicates and selection based on title and abstracts, nine studies were found eligible for further analysis: two randomised controlled trials, and seven observational studies. One randomised controlled trial found a higher polyethylene wear rate in uncemented acetabular components, while the other found no differences. Three out of seven observational studies showed a higher polyethylene wear in uncemented acetabular component fixation; the other four studies did not show any differences in wear rates. The available evidence suggests that a higher annual wear rate may be encountered in uncemented acetabular components as compared to cemented components

    Leucemia linfocĂ­tica aguda

    Get PDF
    This article presents and discusses the case of a 38 year-old black female patient admitted to Hospital das Clínicas de Porto Alegre with fever, weight loss, petechiae, splenomegaly and systolic murmur. The patient received IV cefepime. The results of bone marrow tests were consistent with the diagnosis of pre-B acute lymphocytic leukemia (ALL). The patient received erythrocyte transfusions and chemotherapy with vincristine and daunorubicin. Six days after the admission, the patient presented anxiety and tachypnea. Diazepam 5 mg was administered. The patient had several episodes of cardiorespiratory arrest and died.O artigo apresenta e discute o caso de uma paciente de 38 anos, negra, internada no Hospital de Clínicas de Porto Alegre, apresentando febre, emagrecimento, petéquias, esplenomegalia e sopro sistólico. Foi medicada com cefepime EV. Através do exame de medula óssea, realizou-se o diagnóstico de leucemia linfocítica aguda (LLA) pré-B. A paciente recebeu transfusões de hemácias e quimioterapia com vincristina e daunorubicina. Seis dias após a internação, a paciente apresentava ansiedade e taquipnéia. Recebeu diazepam 5 mg. Sofreu várias paradas cardiorrespiratórias e evoluiu ao óbito

    Measurement of migration of a humeral head resurfacing prosthesis using radiostereometry without implant marking: An experimental study

    Get PDF
    Today, the shoulder joint is the third most commonly replaced joint after the hip and knee joints and the incidence is increasing. In Sweden, 1863 primary Shoulder Arthroplasties and 195 revisions were performed in 2017. The most common diagnoses are Osteoarthritis and irreparable tears of the rotator cuff, with or without arthropathy, often referred to as cuff tear arthropathy. Different Shoulder Arthroplasty (SA) concepts include anatomical total shoulder arthroplasty (TSA), hemiarthroplasty (HSA) and reversed shoulder arthroplasty, but also humeral head resurfacing (HHR) and stemless arthroplasties. All concepts offer pain relief, improvement of function and in quality of life for the different diagnoses. Unfortunately, there are sometimes complications after SA. They involve periprosthetic joint infection, humeral and glenoid fractures, stress shielding, loosening of the glenoid and humeral component but also glenoid erosion and cuff rupture. Some of these complications are most common within 1 year after operation, some after several years, both may lead to a revision. This, together with the fact that new designs of implants and methods of fixation of SA continues to develop, stresses the importance of continuous monitoring of implant survival and follow-up. The overall aim of this thesis was to describe clinical examples of different methods to assess the outcome after Shoulder Arthroplasty. The most common methods are clinical examination, radiographic assessment, Patient Reported Outcome Measure (PROM), National Joint registries, where revisions are an important outcome, but also Clinical Trials. All of these methods are used in one or more of the 4 papers in this thesis and shows the complexity of the topic and the practical work. In paper I we used Radio Stereometric Analysis (RSA) in an experimental set-up and concluded that marker-free RSA can be used for a humeral head resurfacing arthroplasty. In paper II we used data from the Swedish Shoulder Arthroplasty Registry (SSAR) with PROM and revisions to conclude that age is the only factor that affects revision when comparing HSA and HHR. Paper III is a long-time follow-up of a Randomized controlled study where we used radiological assessment, PROM and revisions. The conclusion was that both TSA and HSA develop severe radiological changes 10 year after primary operation. Paper IV is a prospective RSA cohort study where we also evaluated PROM and revisions. The conclusion is that HHR seems to obtain a secure fixation in the humerus, after an initial migration. But also that the prostheses shows continuous glenoid wear. The main conclusion of this thesis is that patient’s operated with SA needs continuous monitoring and several methods may be used to evaluate the outcome
    • …
    corecore