25 research outputs found

    New investigations into macular pigment optical density

    Get PDF
    Macular pigment (MP) is the collective name for three carotenoids, lutein, zeaxanthin and meso-zeaxanthin, which are found at high concentrations in the central macula. The macular carotenoids, like all carotenoids, are entirely of dietary origin. The term ‘macular pigment optical density’ (MPOD) refers to the peak concentration of MP in the retina, which varies from one individual to the next and is measurable in vivo. On account of its blue-light-filtering and antioxidant properties, MP has become a subject of interest with respect to age-related macular degeneration (AMD), the hypothesis being that MP helps to protect against AMD; the higher the MPOD, the lower the risk for AMD. Recently, a new MPOD-measuring device, the MPS 9000 (MPS), entered the ophthalmic market. Using this device, the research described here aimed to contribute new information to the MP literature. A second MPOD instrument, the Macular Pigment Reflectometer, was also used at times, but a reliability study (included in the thesis) demonstrated that it was unsuitable for use on its own. First, a series of exploratory investigations were undertaken to maximize the accuracy and consistency of MPOD measurements taken with the MPS; a protocol was established that substantially improved repeatability. Subsequently, a series of MPOD-based studies were conducted on anisometropia, South Asian race, blue-light-filtering contact lenses, and dietary modification with kale. The principle findings were as follows: interocular MPOD differences were not attributable to interocular refractive error differences; young adults of South Asian origin had significant gender-related MPOD differences (males>females, p<0.01), and they also had significantly higher MPOD than Caucasians (p<0.0005); wearing blue-light-filtering contact lenses for eight months did not affect MPOD; and dietary modification with kale for 16 weeks did not increase MPOD. This body of research adds new insights to MP knowledge, which in turn may contribute to MP knowledge in the context of AMD

    Measuring macular pigment optical density in vivo:a review of techniques

    Get PDF
    Macular pigment has been the focus of much attention in recent years, as a potential modifiable risk factor for age-related macular degeneration. This interest has been heightened by the ability to measure macular pigment optical density (MPOD) in vivo

    Macular pigment optical density in young adults of South Asian origin

    Get PDF
    Purpose: To assess the range of macular pigment optical density (MPOD) in a healthy group of young adults of South Asian origin; to investigate whether any dietary factors or personal characteristics were related to inter-subject variations in MPOD; and to compare the mean MPOD of the South Asian group with the mean MPOD of a white group. Methods: Heterochromatic flicker photometry was used to measure the MP levels of 169 healthy volunteers, of which 117 were Asian and 52 were white. In addition, the Asian participants completed a questionnaire pertaining to the various physical, ocular, lifestyle, dietary and environmental factors that may be associated with MPOD or age-related macular degeneration (AMD). Results: The mean MPOD of the Asian subjects was 0.43±0.14. The male participants had a higher mean MPOD than the females (0.47±0.13 vs 0.41±0.14, p<0.01). Possible associations also emerged between MPOD and form of refractive correction, and iris colour. No MPOD associations were found for the other variables examined in the questionnaire. The mean MPOD of the white subject group was 0.33±0.13, which was significantly lower than the Asian group (p<0.0005). Conclusions: This study adds to the currently limited information on MPOD in South Asians, and while a comparison between Asians and Whites was not the main focus here, highly significant differences between these two ethnicities were revealed. This provokes the possibility that South Asian individuals could have a lower risk for AMD, and it warrants further study

    Clinical evaluation of the MPS 9000 Macular Pigment Screener

    Get PDF
    Background/aims The MPS 9000 uses a psychophysical technique known as heterochromatic flicker photometry to measure macular pigment optical density (MPOD). Our aim was to determine the measurement variability (noise) of the MPS 9000. Methods Forty normally sighted participants who ranged in age from 18 to 50 years (25.4±8.2 years) were recruited from staff and students of Aston University (Birmingham, UK). Data were collected by two operators in two sessions separated by 1 week in order to assess test repeatability and reproducibility. Results The overall mean MPOD for the cohort was 0.35±0.14. There was no significant negative correlation between MPS 9000 MPOD readings and age (r=-0.192, p=0.236). Coefficients were 0.33 and 0.28 for repeatability, and 0.25 and 0.26 for reproducibility. There was no significant correlation between mean and difference MPOD values for any of the four pairs of results. Conclusions When MPOD is being monitored over time then any change less than 0.33 units should not be considered clinically significant as it is very likely to be due to measurement noise. The size of the coefficient appears to be positively correlated with MPOD

    Colour contrast sensitivity in eyes at high risk of neovascular age-related macular degeneration

    Get PDF
    Purpose: To generate the first published reference database of colour contrast sensitivity in eyes at high risk of neovascular age-related macular degeneration and to explore this important feature in quality of vision. Background: Quality of vision depends on many factors. Changes in chromatic contrast sensitivity remain largely unexplored in eyes at high risk of neovascular age-related macular degeneration; they may however not only be relevant for quality of life but also an early indicator of the onset of the disease, so it is important to have a means to evaluate any variation in colour contrast sensitivity, especially in view of the likely increase in neovascular age-related macular degeneration as the population ages. Methods: This prospective longitudinal study evaluated colour contrast sensitivity along the protan and tritan colour axes in 145 eyes at high risk of neovascular age-related macular degeneration. Results: Colour contrast sensitivity showed statistically significant correlations with age and visual acuity, but not gender nor laterality (i.e. whether the right or left eye was being tested). There was significant variability among individuals, especially for the tritan axis, with some subjects well within normal limits for age and others with very poor colour contrast sensitivity. Conclusion: This study has generated the first published colour contrast sensitivity reference database for eyes at high risk of neovascular age-related macular degeneration. It has also shown a high inter-individual variability of colour contrast sensitivity in eyes at high risk of neovascular age-related macular degeneration, but the significance of this is unclear. Further work is required to establish if eyes with high colour contrast sensitivity thresholds (i.e. poor colour vision) have a higher risk of developing neovascular age-related macular degeneration over time, and this is the subject of ongoing work

    Hollow silicon microneedle fabrication using advanced plasma etch technologies for applications in transdermal drug delivery

    Get PDF
    A novel production process flow is presented here for the manufacture of hollow silicon microneedles using deep reactive-ion etching (DRIE) technology. The patent-pending three-step process flow has been developed to produce multiple arrays of sharp-tipped, hollow microneedles, which facilitate easy insertion and controlled fluid injection into excised skin samples. A bevelled tip and vertical sidewalls for the microneedle have been achieved with good uniformity, despite >45% open etch area. Processing steps and etch challenges are discussed, and preliminary skin testing results are presented, showing effective needle insertion and delivery of fluorescent dye into ex vivo skin from human breast tissue

    Design, fabrication, and characterisation of a silicon microneedle array for transdermal therapeutic delivery using a single step wet etch process

    Get PDF
    The fabrication of silicon in-plane microneedle arrays from a simple single wet etch step is presented. The characteristic 54.7° sidewall etch angle obtained via KOH etching of (1 0 0) orientation silicon wafers has been used to create a novel microneedle design. The KOH simultaneously etches both the front and back sides of the wafer to produce V shaped grooves, that intersect to form a sharp pyramidal six-sided microneedle tip. This method allows fabrication of solid microneedles with different geometries to determine the optimal microneedle length and width for effective penetration and minimally invasive drug delivery. A modified grooved microneedle design can also be used to create a hollow microneedle, via bonding of two grooved microneedles together, creating an enclosed hollow channel. The microneedle arrays developed, effectively penetrate the skin without significant indentation, thereby enabling effective delivery of active ingredients via either a poke and patch application using solid microneedles or direct injection using hollow microneedles. This simple, scalable and cost effective method utilises KOH to etch the silicon wafer in-plane, allowing microneedles with variable length of several mm to be fabricated, as opposed to out-of-plane MNs, which are geometrically restricted to dimensions less than the thickness of the wafer. These microneedle arrays have been used to demonstrate effective delivery of insulin and hyaluronic acid into the skin

    Improving the repeatability of heterochromatic flicker photometry for measurement of macular pigment optical density

    Get PDF
    Background: Heterochromatic flicker photometry (HFP) is a psychophysical technique used to measure macular pigment optical density (MPOD). We used the MPS 9000 (MPS) HFP device. Our aim was to determine if the repeatability of the MPS could be improved to make it more suitable for monitoring MPOD over time. Methods: Intra-session repeatability was assessed in 25 participants (aged 20-50 years). The resulting data was explored in detail, e.g., by examining the effect of removal and adjustment of data with less than optimal quality parameters. A protocol was developed for improved overall reliability, which was then tested in terms of inter-session repeatability in a separate group of 27 participants (aged 19-52 years). Results: Removal and adjustment of data reduced the intra-session coefficient of repeatability (CR) by 0.04, on average, and the mean individual standard deviation by 0.004. Raw data observation offered further insight into ways of improving repeatability. The proposed protocol resulted in an inter-session CR of 0.08. Conclusions: Removal and adjustment of less than optimal data improved repeatability, and is therefore recommended. To further improve repeatability, in brief we propose that each patient perform each part of the test twice, and a third time where necessary (described in detail by the protocol). Doing so will make the MPS more useful in research and clinical settings. © 2012 Springer-Verlag

    IMPACT-Global Hip Fracture Audit: Nosocomial infection, risk prediction and prognostication, minimum reporting standards and global collaborative audit. Lessons from an international multicentre study of 7,090 patients conducted in 14 nations during the COVID-19 pandemic

    Get PDF

    Finishing the euchromatic sequence of the human genome

    Get PDF
    The sequence of the human genome encodes the genetic instructions for human physiology, as well as rich information about human evolution. In 2001, the International Human Genome Sequencing Consortium reported a draft sequence of the euchromatic portion of the human genome. Since then, the international collaboration has worked to convert this draft into a genome sequence with high accuracy and nearly complete coverage. Here, we report the result of this finishing process. The current genome sequence (Build 35) contains 2.85 billion nucleotides interrupted by only 341 gaps. It covers ∼99% of the euchromatic genome and is accurate to an error rate of ∼1 event per 100,000 bases. Many of the remaining euchromatic gaps are associated with segmental duplications and will require focused work with new methods. The near-complete sequence, the first for a vertebrate, greatly improves the precision of biological analyses of the human genome including studies of gene number, birth and death. Notably, the human enome seems to encode only 20,000-25,000 protein-coding genes. The genome sequence reported here should serve as a firm foundation for biomedical research in the decades ahead
    corecore