    The Negligible Influence of Chronic Obesity on Hospitalization, Clinical Status, and Complications in Elective Posterior Lumbar Interbody Fusion

    Get PDF
    Background. Posterior lumbar interbody fusion (PLIF) is a common surgical treatment for degenerative spinal instability, but many surgeons consider obesity a contraindication for elective spinal fusion. The aim of this study was to analyze whether obesity has any influence on hospitalization parameters, change in clinical status, or complications. Methods. In this prospective study, regression analysis was used to analyze the influence of the body mass index (BMI) on operating time, postoperative care, hospitalization time, type of postdischarge care, change in paresis or sensory deficits, pain level, wound complications, cerebrospinal fluid leakage, and implant complications. Results. Operating time increased only 2.5 minutes for each increase of BMI by 1. The probability of having a wound complication increased statistically with rising BMI. Nonetheless, BMI accounted for very little of the variation in the data, meaning that other factors or random chances play a much larger role. Conclusions. Obesity has to be considered a risk factor for wound complications in patients undergoing elective PLIF for degenerative instability. However, BMI showed no significant influence on other kinds of peri-or postoperative complications, nor clinical outcomes. So obesity cannot be considered a contraindication for elective PLIF

    Study on the clinical application of pulsed DC magnetic technology for tracking of intraoperative head motion during frameless stereotaxy

    Get PDF
    BACKGROUND: Tracking of post-registration head motion is one of the major problems in frameless stereotaxy. Various attempts in detecting and compensating for this phenomenon rely on a fixed reference device rigidly attached to the patient's head. However, most of such reference tools are either based on an invasive fixation technique or have physical limitations which allow mobility of the head only in a restricted range of motion after completion of the registration procedure. METHODS: A new sensor-based reference tool, the so-called Dynamic Reference Frame (DRF) which is designed to allow an unrestricted, 360° range of motion for the intraoperative use in pulsed DC magnetic navigation was tested in 40 patients. Different methods of non-invasive attachment dependent on the clinical need and type of procedure, as well as the resulting accuracies in the clinical application have been analyzed. RESULTS: Apart from conventional, completely rigid immobilization of the head (type A), four additional modes of head fixation and attachment of the DRF were distinguished on clinical grounds: type B1 = pin fixation plus oral DRF attachment; type B2 = pin fixation plus retroauricular DRF attachment; type C1 = free head positioning with oral DRF; and type C2 = free head positioning with retroauricular DRF. Mean fiducial registration errors (FRE) were as follows: type A interventions = 1.51 mm, B1 = 1.56 mm, B2 = 1.54 mm, C1 = 1.73 mm, and C2 = 1.75 mm. The mean position errors determined at the end of the intervention as a measure of application accuracy were: 1.45 mm in type A interventions, 1.26 mm in type B1, 1.44 mm in type B2, 1.86 mm in type C1, and 1.68 mm in type C2. CONCLUSION: Rigid head immobilization guarantees most reliable accuracy in various types of frameless stereotaxy. The use of an additional DRF, however, increases the application scope of frameless stereotaxy to include e.g. procedures in which rigid pin fixation of the cranium is not required or desired. Thus, continuous tracking of head motion allows highly flexible variation of the surgical strategy including intraoperative repositioning of the patient without impairment of navigational accuracy as it ensures automatic correction of spatial distortion. With a dental cast for oral attachment and the alternative option of non-invasive retroauricular attachment, flexibility in the clinical use of the DRF is ensured

    Evaluation of the operation of co-generation units with biogas combustion

    Get PDF
    Tato bakalářská práce se zabývá analýzou a hodnocením provozu bioplynové stanice. Úvodní část práce obsahuje základní informace týkající se kombinované výroby elektrické energie a tepla. Je zde uveden popis kogeneračních jednotek, druhy technologií i výhody spojené s využitím kogenerace. Další části se zaměřují na výrobu a využití elektrické energie a tepla na bioplynové stanici, a především na analýzu a hodnocení provozu. V poslední části jsou uvedeny metody pro vylepšení provozu bioplynové stanice.This thesis focuses on the analysis and evaluation of the operation of biogas plants. The introductory part contains basic information regarding the combined production of electricity and heat. There is a description of cogeneration units, types of technologies and benefits associated with the use of cogeneration. Another section focuses on the production and use of electricity and heat for the biogas plant, and especially analysis and evaluation of the operation. The last section provides methods for improving the operation of biogas plants.410 - Katedra elektroenergetikyvýborn

    Intraoperative electrocortical stimulation of Brodman area 4: a 10-year analysis of 255 cases

    Get PDF
    BACKGROUND: Brain tumor surgery is limited by the risk of postoperative neurological deficits. Intraoperative neurophysiological examination techniques, which are based on the electrical excitability of the human brain cortex, are thus still indispensable for surgery in eloquent areas such as the primary motor cortex (Brodman Area 4). METHODS: This study analyzed the data obtained from a total of 255 cerebral interventions for lesions with direct contact to (121) or immediately adjacent to (134) Brodman Area 4 in order to optimize stimulation parameters and to search for direct correlation between intraoperative potential changes and specific surgical maneuvers when using monopolar cortex stimulation (MCS) for electrocortical mapping and continuous intraoperative neurophysiological monitoring. RESULTS: Compound muscle action potentials (CMAPs) were recorded from the thenar muscles and forearm flexors in accordance with the large representational area of the hand and forearm in Brodman Area 4. By optimizing the stimulation parameters in two steps (step 1: stimulation frequency and step 2: train sequence) MCS was successful in 91% (232/255) of the cases. Statistical analysis of the parameters latency, potential width and amplitude showed spontaneous latency prolongations and abrupt amplitude reductions as a reliable warning signal for direct involvement of the motor cortex or motor pathways. CONCLUSION: MCS must be considered a stimulation technique that enables reliable qualitative analysis of the recorded potentials, which may thus be regarded as directly predictive. Nevertheless, like other intraoperative neurophysiological examination techniques, MCS has technical, anatomical and neurophysiological limitations. A variety of surgical and non-surgical influences can be reason for false positive or false negative measurements

    The European multicenter trial on the safety and efficacy of guided oblique lumbar interbody fusion (GO-LIF)

    Get PDF
    Background: Because of the implant-related problems with pedicle screw-based spinal instrumentations, other types of fixation have been tried in spinal arthrodesis. One such technique is the direct trans-pedicular, trans-discal screw fixation, pioneered by Grob for spondylolisthesis. The newly developed GO-LIF procedure expands the scope of the Grob technique in several important ways and adds security by means of robotic-assisted navigation. This is the first clinical trial on the GO-LIF procedure and it will assess safety and efficacy. Methods/Design: Multicentric prospective study with n = 40 patients to undergo single level instrumented spinal arthrodesis of the lumbar or the lumbosacral spine, based on a diagnosis of: painful disc degeneration, painful erosive osteochondrosis, segmental instability, recurrent disc herniation, spinal canal stenosis or foraminal stenosis. The primary target criteria with regards to safety are: The number, severity and cause of intra-and perioperative complications. The number of significant penetrations of the cortical layer of the vertebral body by the implant as recognized on postoperative CT. The primary target parameters with regards to feasibility are: Performance of the procedure according to the preoperative plan. The planned follow-up is 12 months and the following scores will be evaluated as secondary target parameters with regards to clinical improvement: VAS back pain, VAS leg pain, Oswestry Disability Index, short form - 12 health questionnaire and the Swiss spinal stenosis questionnaire for patients with spinal claudication. The secondary parameters with regards to construct stability are visible fusion or lack thereof and signs of implant loosening, implant migration or pseudarthrosis on plain and functional radiographs. Discussion: This trial will for the first time assess the safety and efficacy of guided oblique lumbar interbody fusion. There is no control group, but the results, the outcome and the rate of any complications will be analyzed on the background of the literature on instrumented spinal fusion. Despite its limitations, we expect that this study will serve as the key step in deciding whether a direct comparative trial with another fusion technique is warranted

    The Negligible Influence of Chronic Obesity on Hospitalization, Clinical Status, and Complications in Elective Posterior Lumbar Interbody Fusion

    No full text
    Background. Posterior lumbar interbody fusion (PLIF) is a common surgical treatment for degenerative spinal instability, but many surgeons consider obesity a contraindication for elective spinal fusion. The aim of this study was to analyze whether obesity has any influence on hospitalization parameters, change in clinical status, or complications. Methods. In this prospective study, regression analysis was used to analyze the influence of the body mass index (BMI) on operating time, postoperative care, hospitalization time, type of postdischarge care, change in paresis or sensory deficits, pain level, wound complications, cerebrospinal fluid leakage, and implant complications. Results. Operating time increased only 2.5 minutes for each increase of BMI by 1. The probability of having a wound complication increased statistically with rising BMI. Nonetheless, BMI accounted for very little of the variation in the data, meaning that other factors or random chances play a much larger role. Conclusions. Obesity has to be considered a risk factor for wound complications in patients undergoing elective PLIF for degenerative instability. However, BMI showed no significant influence on other kinds of peri- or postoperative complications, nor clinical outcomes. So obesity cannot be considered a contraindication for elective PLIF

    Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system

    No full text
    Lutz Weise, Olaf Suess, Thomas Picht, Theodoros KombosNeurochirurgische Klinik, Charité – Universitätsmedizin Berlin, Berlin, GermanyObjective: Transpedicular screws are commonly and successfully used for posterior fixation in spinal instability, but their insertion remains challenging. Even using navigation techniques, there is a misplacement rate of up to 11%. The aim of this study was to assess the accuracy of a novel pedicle screw system.Methods: Thoracic and lumbar fusions were performed on 67 consecutive patients for tumor, trauma, degenerative disease or infection. A total of 326 pedicular screws were placed using a novel wire-guided, cannulated, polyaxial screw system (XIA Precision®, Stryker). The accuracy of placement was assessed post operatively by CT scan, and the patients were followed-up clinically for a mean of 16 months.Results: The total medio-caudal pedicle wall perforation rate was 9.2% (30/326). In 19 of these 30 cases a cortical breakthrough of less than 2 mm occurred. The misplacement rate (defined as a perforation of 2 mm or more) was 3.37% (11/326). Three of these 11 screws needed surgical revision due to neurological symptoms or CSF leakage. There have been no screw breakages or dislocations over the follow up-period.Conclusion: We conclude that the use of this cannulated screw system for the placement of pedicle screws in the thoracic and lumbar spine is accurate and safe. The advantages of this technique include easy handling without a time-consuming set up. Considering the incidence of long-term screw breakage, further investigation with a longer follow-up period is necessary.Keywords: spinal instrumentation, pedicle screws, misplacement, pedicle wall perforatio