13 research outputs found

    Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Malaria rapid diagnostic tests (RDTs) are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution) or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results.</p> <p>Methods</p> <p>Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and <it>Plasmodium </it>positive samples.</p> <p>Results</p> <p>Only eight cassettes (in four RDT brands) showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74%) RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20), and in 15 RDTs which were run with distilled water only. They occurred for all <it>Plasmodium </it>antigens and RDT formats (two-, three- and four-band RDTs). Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness) of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and <it>Plasmodium </it>positive samples.</p> <p>Conclusion</p> <p>Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results.</p

    Management of uncomplicated malaria in febrile under five-year-old children by community health workers in Madagascar: reliability of malaria rapid diagnostic tests

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Early diagnosis, as well as prompt and effective treatment of uncomplicated malaria, are essential components of the anti-malaria strategy in Madagascar to prevent severe malaria, reduce mortality and limit malaria transmission. The purpose of this study was to assess the performance of the malaria rapid diagnostic tests (RDTs) used by community health workers (CHWs) by comparing RDT results with two reference methods (microscopy and Polymerase Chain Reaction, PCR).</p> <p>Methods</p> <p>Eight CHWs in two districts, each with a different level of endemic malaria transmission, were trained to use RDTs in the management of febrile children under five years of age. RDTs were performed by CHWs in all febrile children who consulted for fever. In parallel, retrospective parasitological diagnoses were made by microscopy and PCR. The results of these different diagnostic methods were analysed to evaluate the diagnostic performance of the RDTs administered by the CHWs. The stability of the RDTs stored by CHWs was also evaluated.</p> <p>Results</p> <p>Among 190 febrile children with suspected malaria who visited CHWs between February 2009 and February 2010, 89.5% were found to be positive for malaria parasites by PCR, 51.6% were positive by microscopy and 55.8% were positive by RDT. The performance accuracy of the RDTs used by CHWs in terms of sensitivity, specificity, positive and negative predictive values was greater than 85%. Concordance between microscopy and RDT, estimated by the Kappa value was 0.83 (95% CI: 0.75-0.91). RDTs stored by CHWs for 24 months were capable of detecting <it>Plasmodium falciparum </it>in blood at a level of 200 parasites/μl.</p> <p>Conclusion</p> <p>Introduction of easy-to-use diagnostic tools, such as RDTs, at the community level appears to be an effective strategy for improving febrile patient management and for reducing excessive use of anti-malarial drugs.</p

    Performance of three multi-species rapid diagnostic tests for diagnosis of Plasmodium falciparum and Plasmodium vivax malaria in Oromia Regional State, Ethiopia

    Get PDF
    BACKGROUND: Malaria transmission in Ethiopia is unstable and variable, caused by both Plasmodium falciparum and Plasmodium vivax. The Federal Ministry of Health (FMoH) is scaling up parasitological diagnosis of malaria at all levels of the health system; at peripheral health facilities this will be through use of rapid diagnostic tests (RDTs). The present study compared three RDT products to provide the FMoH with evidence to guide appropriate product selection. METHODS: Performance of three multi-species (pf-HRP2/pan-pLDH and pf-HRP2/aldolase) RDTs (CareStart, ParaScreen and ICT Combo) was compared with 'gold standard' microscopy at three health centres in Jimma zone, Oromia Regional State. Ease of RDT use by health extension workers was assessed at community health posts. RDT heat stability was tested in a controlled laboratory setting according to WHO procedures. RESULTS: A total of 2,383 patients with suspected malaria were enrolled between May and July 2009, 23.2% of whom were found to be infected with Plasmodium parasites by microscopy. All three RDTs were equally sensitive in detecting P. falciparum or mixed infection: 85.6% (95% confidence interval 81.2-89.4). RDT specificity was similar for detection of P. falciparum or mixed infection at around 92%. For detecting P. vivax infection, all three RDTs had similar sensitivity in the range of 82.5 to 85.0%. CareStart had higher specificity in detecting P. vivax (97.2%) than both ParaScreen and ICT Combo (p < 0.001 and p = 0.05, respectively). Health extension workers preferred CareStart and ParaScreen to ICT Combo due to the clear labelling of bands on the cassette, while the 'lab in a pack' style of CareStart was the preferred design. ParaScreen and CareStart passed all heat stability testing, while ICT Combo did not perform as well. CONCLUSIONS: CareStart appeared to be the most appropriate option for use at health posts in Ethiopia, considering the combination of quantitative performance, ease of use and heat stability. When new products become available, the choice of multi-species RDT for Ethiopia should be regularly re-evaluated, as it would be desirable to identify a test with higher sensitivity than the ones evaluated here

    External quality assessment on the use of malaria rapid diagnostic tests in a non-endemic setting

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Malaria rapid diagnostic tests (RDTs) are increasingly used as a tool for the diagnosis of malaria, both in endemic and in non-endemic settings. The present study reports the results of an external quality assessment (EQA) session on RDTs in a non-endemic setting.</p> <p>Methods</p> <p>After validation of antigen stability during shipment at room temperature, three clinical samples and a questionnaire were sent to clinical laboratories in Belgium and the Grand Duchy of Luxembourg using malaria RDTs. Participants were asked to report the results of the RDTs as observations (visibility of the RDT control and test lines) and interpretations (report as formulated to the clinician). In addition, participants were invited to fill in a questionnaire on the place of RDTs in the diagnostic strategy of malaria.</p> <p>Results</p> <p>A total of 128/133 (96.2%) of clinical laboratories using RDTs participated. Six three-band and one four-band RDT brands were used. Analytical errors were rare and included (i) not recognizing invalid RDT results (1.6%) and (ii) missing the diagnosis of <it>Plasmodium falciparum </it>(0.8%). Minor errors were related to RDT test result interpretation and included (i) reporting "RDT positive" without species identification in the case of <it>P. falciparum </it>and non-<it>falciparum </it>species (16.9% and 6.5% respectively) and (ii) adding incorrect comments to the report (3.2%). Some of these errors were related to incorrect RDT package insert instructions such as (i) not reporting the possibility of mixed species infection in the case of <it>P. falciparum </it>and <it>Plasmodium vivax </it>(35.5% and 18.5% respectively) and (ii) the interpretation of <it>P. vivax </it>instead of non-falciparum species at the presence of a pan-species antigen line (4.0%). According to the questionnaire, 48.8% of participants processed ≤20 requests for malaria diagnosis in 2009. During opening hours, 93.6% of 125 participants used RDTs as an adjunct to microscopy but outside opening hours, nearly one third of 113 participants relied on RDTs as the primary (4.4%) or the single tool (25.7%) for malaria diagnosis.</p> <p>Conclusion</p> <p>In this non-endemic setting, errors in RDT performance were mainly related to RDT test line interpretations, partly due to incorrect package insert instructions. The reliance on RDTs as the primary or the single tool for the diagnosis of malaria outside opening hours is of concern and should be avoided.</p

    Malaria rapid diagnostic kits: quality of packaging, design and labelling of boxes and components and readability and accuracy of information inserts

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The present study assessed malaria RDT kits for adequate and correct packaging, design and labelling of boxes and components. Information inserts were studied for readability and accuracy of information.</p> <p>Methods</p> <p>Criteria for packaging, design, labelling and information were compiled from Directive 98/79 of the European Community (EC), relevant World Health Organization (WHO) documents and studies on end-users' performance of RDTs. Typography and readability level (Flesch-Kincaid grade level) were assessed.</p> <p>Results</p> <p>Forty-two RDT kits from 22 manufacturers were assessed, 35 of which had evidence of good manufacturing practice according to available information (<it>i.e</it>. CE-label affixed or inclusion in the WHO list of ISO13485:2003 certified manufacturers). Shortcomings in devices were (i) insufficient place for writing sample identification (n = 40) and (ii) ambiguous labelling of the reading window (n = 6). Buffer vial labels were lacking essential information (n = 24) or were of poor quality (n = 16). Information inserts had elevated readability levels (median Flesch Kincaid grade 8.9, range 7.1 - 12.9) and user-unfriendly typography (median font size 8, range 5 - 10). Inadequacies included (i) no referral to biosafety (n = 18), (ii) critical differences between depicted and real devices (n = 8), (iii) figures with unrealistic colours (n = 4), (iv) incomplete information about RDT line interpretations (n = 31) and no data on test characteristics (n = 8). Other problems included (i) kit names that referred to <it>Plasmodium vivax </it>although targeting a pan-species <it>Plasmodium </it>antigen (n = 4), (ii) not stating the identity of the pan-species antigen (n = 2) and (iii) slight but numerous differences in names displayed on boxes, device packages and information inserts. Three CE labelled RDT kits produced outside the EC had no authorized representative affixed and the shape and relative dimensions of the CE symbol affixed did not comply with the Directive 98/79/EC. Overall, RDTs with evidence of GMP scored better compared to those without but inadequacies were observed in both groups.</p> <p>Conclusion</p> <p>Overall, malaria RDTs showed shortcomings in quality of construction, design and labelling of boxes, device packages, devices and buffers. Information inserts were difficult to read and lacked relevant information.</p

    Management of uncomplicated malaria in children under 13 years of age at a district hospital in Senegal: from official guidelines to usual practices.

    Get PDF
    BACKGROUND: To be effective, national malaria guidelines must be properly followed. This study evaluated nurses' practices in the management of uncomplicated malaria cases at a District Hospital. Its objective was to identify the reasons for discrepancies between official guidelines and usual practices. METHODS: This study took place at Oussouye hospital, south-western Senegal. Blood smears were available for biological diagnosis in patients aged more than five years while the Integrated Management of Childhood Illness recommended treating fevers presumptively in children under five. First line anti-malarial was Amodiaquine plus sulphadoxine-pyrimethamine (AQ+SP) bi-therapy. Hospital records of children under 13 years of age seen between 2004 and 2005 were reviewed. RESULTS: Among children treated with anti-malarials, 74% (2, 063/2, 789) received AQ+SP. However, only 22% (406/1, 879) of febrile children and 19% (429/2, 198) of children diagnosed with malaria got a blood smear. Moreover, an anti-malarial was prescribed for 80% (377/474) of children with a negative blood smear. CONCLUSIONS: The transition from chloroquine to AQ+SP was well followed. Nonetheless, blood smear use was very low and many over-prescriptions were reported. Reasons for discrepancies between guidelines and practices can be classified in three main categories: ambiguous guidelines, health system's dysfunctions and nurses' own considerations. Aside from the strengthening of the public health system, in order to guarantee practices complying with guidelines, training content should be more adapted to nurses' own considerations

    Blood transfer devices for malaria rapid diagnostic tests: evaluation of accuracy, safety and ease of use

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Malaria rapid diagnostic tests (RDTs) are increasingly used by remote health personnel with minimal training in laboratory techniques. RDTs must, therefore, be as simple, safe and reliable as possible. Transfer of blood from the patient to the RDT is critical to safety and accuracy, and poses a significant challenge to many users. Blood transfer devices were evaluated for accuracy and precision of volume transferred, safety and ease of use, to identify the most appropriate devices for use with RDTs in routine clinical care.</p> <p>Methods</p> <p>Five devices, a loop, straw-pipette, calibrated pipette, glass capillary tube, and a new inverted cup device, were evaluated in Nigeria, the Philippines and Uganda. The 227 participating health workers used each device to transfer blood from a simulated finger-prick site to filter paper. For each transfer, the number of attempts required to collect and deposit blood and any spilling of blood during transfer were recorded. Perceptions of ease of use and safety of each device were recorded for each participant. Blood volume transferred was calculated from the area of blood spots deposited on filter paper.</p> <p>Results</p> <p>The overall mean volumes transferred by devices differed significantly from the target volume of 5 microliters (p < 0.001). The inverted cup (4.6 microliters) most closely approximated the target volume. The glass capillary was excluded from volume analysis as the estimation method used is not compatible with this device. The calibrated pipette accounted for the largest proportion of blood exposures (23/225, 10%); exposures ranged from 2% to 6% for the other four devices. The inverted cup was considered easiest to use in blood collection (206/226, 91%); the straw-pipette and calibrated pipette were rated lowest (143/225 [64%] and 135/225 [60%] respectively). Overall, the inverted cup was the most preferred device (72%, 163/227), followed by the loop (61%, 138/227).</p> <p>Conclusions</p> <p>The performance of blood transfer devices varied in this evaluation of accuracy, blood safety, ease of use, and user preference. The inverted cup design achieved the highest overall performance, while the loop also performed well. These findings have relevance for any point-of-care diagnostics that require blood sampling.</p