11,799 research outputs found

    An electromagnetic shashlik calorimeter with longitudinal segmentation

    Get PDF
    A novel technique for longitudinal segmentation of shashlik calorimeters has been tested in the CERN West Area beam facility. A 25 tower very fine samplings e.m. calorimeter has been built with vacuum photodiodes inserted in the first 8 radiation lengths to sample the initial development of the shower. Results concerning energy resolution, impact point reconstruction and electron/pion separation are reported.Comment: 13 pages, 12 figure

    Experimental study of direct photon emission in K- --> pi- pi0 gamma decay using ISTRA+ detector

    Full text link
    The branching ratio in the charged-pion kinetic energy region of 55 to 90 MeV for the direct photon emission in the K- --> pi- pi0 gamma decay has been measured using in-flight decays detected with the ISTRA+ setup operating in the 25 GeV/c negative secondary beam of the U-70 PS. The value Br(DE)=[0.37+-0.39(stat)+-0.10(syst)]*10^(-5) obtained from the analysis of 930 completely reconstructed events is consistent with the average value of two stopped-kaon experiments, but it differs by 2.5 standard deviations from the average value of three in-flight-kaon experiments. The result is also compared with recent theoretical predictions.Comment: 13 pages, 8 figure

    Measurement of the K+μ+νμγK^+\rightarrow{\mu^+}{\nu_{\mu}}{\gamma} decay form factors in the OKA experiment

    Full text link
    A precise measurement of the vector and axial-vector form factors difference FVFAF_V-F_A in the K+μ+νμγK^+\rightarrow{\mu^+}{\nu_{\mu}}{\gamma} decay is presented. About 95K events of K+μ+νμγK^+\rightarrow{\mu^+}{\nu_{\mu}}{\gamma} are selected in the OKA experiment. The result is FVFA=0.134±0.021(stat)±0.027(syst)F_V-F_A=0.134\pm0.021(stat)\pm0.027(syst). Both errors are smaller than in the previous FVFAF_V-F_A measurements.Comment: 9 pages, 8 figure

    Ke3K_{e3} decay studies in OKA experiment

    Full text link
    Recent results from OKA setup concerning form factor studies in Ke3K_{e3} decay are presented. About 5.25M events are selected for the analysis. The linear and quadratic slopes for the decay formfactor f+(t)f_{+}(t) are measured: λ+=(26.1±0.35±0.28)×103\lambda'_{+}=(26.1 \pm 0.35 \pm 0.28 )\times 10^{-3}, λ"+=(1.91±0.19±0.14)×103\lambda"_{+}=(1.91 \pm 0.19 \pm 0.14)\times 10^{-3}. The scalar and tensor contributions are compatible with zero. Several alternative parametrizations are tried: the Pole fit parameter is found to be MV=891±2.0M_V = 891 \pm 2.0 MeV ; the parameter of the Dispersive parametrization is measured to be Λ+=(24.58±0.18)×103\Lambda_+ =(24.58 \pm 0.18) \times 10^{-3}. The presented results are considered as preliminary

    An electromagnetic shashlik calorimeter with longitudinal segmentation

    Get PDF
    A novel technique for longitudinal segmentation of shashlik calorimeters has been tested in the CERN West Area beam facility. A 25 tower e.m. calorimeter has been built with vacuum photodiodes inserted in the first 8 radiation lengths to sample the initial development of the shower. Results concerning energy resolution, impact point reconstruction and e/πe/\pi separation are reported.A novel technique for longitudinal segmentation of shashlik calorimeters has been tested in the CERN West Area beam facility. A 25 tower very fine samplings e.m. calorimeter has been built with vacuum photodiodes inserted in the first 8 radiation lengths to sample the initial development of the shower. Results concerning energy resolution, impact point reconstruction and electron/pion separation are reported

    Glass-Coated Beryllium Mirrors for the LHCb RICH1 Detector

    Get PDF
    The design, manufacture and testing of lightweight glass-coated beryllium spherical converging mirrors for the RICH1 detector of LHCb are described. The mirrors need to be lightweight to minimize the material budget and fluorocarbon-compatible to avoid degradation in the RICH1 C4F10 gas radiator. Results of the optical measurements for the small-sized prototypes and for the first full-sized prototype mirror are reported
    corecore