82 research outputs found

    The GREGOR Fabry-P\'erot Interferometer

    Full text link
    The GREGOR Fabry-P\'erot Interferometer (GFPI) is one of three first-light instruments of the German 1.5-meter GREGOR solar telescope at the Observatorio del Teide, Tenerife, Spain. The GFPI uses two tunable etalons in collimated mounting. Thanks to its large-format, high-cadence CCD detectors with sophisticated computer hard- and software it is capable of scanning spectral lines with a cadence that is sufficient to capture the dynamic evolution of the solar atmosphere. The field-of-view (FOV) of 50" x 38" is well suited for quiet Sun and sunspot observations. However, in the vector spectropolarimetric mode the FOV reduces to 25" x 38". The spectral coverage in the spectroscopic mode extends from 530-860 nm with a theoretical spectral resolution R of about 250,000, whereas in the vector spectropolarimetric mode the wavelength range is at present limited to 580-660 nm. The combination of fast narrow-band imaging and post-factum image restoration has the potential for discovery science concerning the dynamic Sun and its magnetic field at spatial scales down to about 50 km on the solar surface.Comment: 14 pages, 17 figures, 4 tables; pre-print of AN 333, p.880-893, 2012 (AN special issue to GREGOR

    Status of the Super-B factory Design

    Full text link
    The SuperB international team continues to optimize the design of an electron-positron collider, which will allow the enhanced study of the origins of flavor physics. The project combines the best features of a linear collider (high single-collision luminosity) and a storage-ring collider (high repetition rate), bringing together all accelerator physics aspects to make a very high luminosity of 1036^{36} cm−2^{-2} sec−1^{-1}. This asymmetric-energy collider with a polarized electron beam will produce hundreds of millions of B-mesons at the ΄\Upsilon(4S) resonance. The present design is based on extremely low emittance beams colliding at a large Piwinski angle to allow very low ÎČy⋆\beta_y^\star without the need for ultra short bunches. Use of crab-waist sextupoles will enhance the luminosity, suppressing dangerous resonances and allowing for a higher beam-beam parameter. The project has flexible beam parameters, improved dynamic aperture, and spin-rotators in the Low Energy Ring for longitudinal polarization of the electron beam at the Interaction Point. Optimized for best colliding-beam performance, the facility may also provide high-brightness photon beams for synchrotron radiation applications

    Measurement of J/Ïˆâ†’ÎłÎ·cJ/\psi\to\gamma\eta_{\rm c} decay rate and ηc\eta_{\rm c} parameters at KEDR

    Full text link
    Using the inclusive photon spectrum based on a data sample collected at the J/ψJ/\psi peak with the KEDR detector at the VEPP-4M e+e−e^+e^- collider, we measured the rate of the radiative decay J/Ïˆâ†’ÎłÎ·cJ/\psi\to\gamma\eta_{\rm c} as well as ηc\eta_{\rm c} mass and width. Taking into account an asymmetric photon lineshape we obtained Γγηc0=2.98±0.18∣−0.33+0.15\Gamma^0_{\gamma\eta_{\rm c}}=2.98\pm0.18 \phantom{|}^{+0.15}_{-0.33} keV, Mηc=2983.5±1.4∣−3.6+1.6M_{\eta_{\rm c}} = 2983.5 \pm 1.4 \phantom{|}^{+1.6}_{-3.6} MeV/c2c^2, Γηc=27.2±3.1∣−2.6+5.4\Gamma_{\eta_{\rm c}} = 27.2 \pm 3.1 \phantom{|}^{+5.4}_{-2.6} MeV.Comment: 6 pages, 3 figure

    Measurement of J/psi to eta_c gamma at KEDR

    Full text link
    We present a study of the inclusive photon spectra from 5.9 million J/psi decays collected with the KEDR detector at the VEPP-4M e+e- collider. We measure the branching fraction of radiative decay J/psi to eta_c gamma, eta_c width and mass. Our preliminary results are: M(eta_c) = 2979.4+-1.5+-1.9 MeV, G(eta_c) = 27.8+-5.1+-3.3 MeV, B(J/psi to eta_c gamma) = (2.34+-0.15+-0.40)%.Comment: To be published in Proceedings of the PhiPsi09, Oct. 13-16, 2009, Beijing, Chin

    Measurement of B(J/psi->eta_c gamma) at KEDR

    Full text link
    We present a study of the inclusive photon spectrum from 6.3 million J/psi decays collected with the KEDR detector at the VEPP-4M e+e- collider. We measure the branching fraction of the radiative decay J/psi -> eta_c gamma, eta_c width and mass. Taking into account an asymmetric photon line shape we obtain: M(eta_c) = (2978.1 +- 1.4 +- 2.0) MeV/c^2, Gamma(eta_c) = (43.5 +- 5.4 +- 15.8) MeV, B(J/psi->eta_c gamma) = (2.59 +- 0.16 +- 0.31)%$.Comment: 6 pages, 1 figure. To be published in the proceedings of the 4th International Workshop on Charm Physics (Charm2010), October 21-24, 2010, IHEP, Beijin

    Precise measurement of RudsR_{\text{uds}} and RR between 1.84 and 3.72 GeV at the KEDR detector

    Full text link
    The present work continues a series of the KEDR measurements of the RR value that started in 2010 at the VEPP-4M e+e−e^+e^- collider. By combining new data with our previous results in this energy range we measured the values of RudsR_{\text{uds}} and RR at nine center-of-mass energies between 3.08 and 3.72 GeV. The total accuracy is about or better than 2.6%2.6\% at most of energy points with a systematic uncertainty of about 1.9%1.9\%. Together with the previous precise RR measurement at KEDR in the energy range 1.84-3.05 GeV, it constitutes the most detailed high-precision RR measurement near the charmonium production threshold.Comment: arXiv admin note: text overlap with arXiv:1610.02827 and substantial text overlap with arXiv:1510.0266

    Small-scale solar magnetic fields

    Get PDF
    As we resolve ever smaller structures in the solar atmosphere, it has become clear that magnetism is an important component of those small structures. Small-scale magnetism holds the key to many poorly understood facets of solar magnetism on all scales, such as the existence of a local dynamo, chromospheric heating, and flux emergence, to name a few. Here, we review our knowledge of small-scale photospheric fields, with particular emphasis on quiet-sun field, and discuss the implications of several results obtained recently using new instruments, as well as future prospects in this field of research.Comment: 43 pages, 18 figure

    Epidemiological Situation on Natural Focal Infectious Diseases of Bacterial and Viral Etiology in 2012 in the Territory of Siberia and Far East, and Prognosis for 2013

    Get PDF
    Analyzed is the incidence rate as regards natural focal infections of bacterial and viral etiology. Displayed is the data on the performed laboratory diagnostics of these infections in the territory of Siberia and Far East in 2012 and forecast of the epidemiological situation development in 2013. Analysis is carried out based on the data received by the Reference Center for surveillance over natural focal infections at the Irkutsk Research Anti-Plague Institute, from Rospotrebnadzor Institutions of Siberian, Far-Eastern and Ural Federal districts, as well as reviews and prognoses on the current state of natural foci of infections available from Altay, Tuva, Chita, Khabarovsk and Primorsk plague control stations

    SuperB: next-generation e+e- B-factory collider

    Get PDF
    International audienceThe SuperB international team continues to optimize the design of an electron-positron collider, which will allow the enhanced study of the origins of ïŹ‚avor physics. The project combines the best features of a linear collider (high single- collision luminosity) and a storage-ring collider (high rep- etition rate), bringing together all accelerator physics as- pects to make a very high luminosity of 10^36 cm^−2 sec^−1 . This asymmetric-energy collider with a polarized electron beam will produce hundreds of millions of B-mesons at the ΄(4S) resonance. The present design is based on ex- tremely low emittance beams colliding at a large Piwin- ski angle to allow very low ÎČ⋆y without the need for ultra short bunches. Use of crab-waist sextupoles will enhance the luminosity, suppressing dangerous resonances and al- lowing for a higher beam-beam parameter. The project has ïŹ‚exible beam parameters, improved dynamic aperture, and spin-rotators in the Low Energy Ring for longitudinal po- larization of the electron beam at the Interaction Point. Op- timized for best colliding-beam performance, the facility may also provide high-brightness photon beams for syn- chrotron radiation applications
    • 

    corecore