30 research outputs found

    Analysis of vaginal microbicide film hydration kinetics by quantitative imaging refractometry

    Get PDF
    We have developed a quantitative imaging refractometry technique, based on holographic phase microscopy, as a tool for investigating microscopic structural changes in water-soluble polymeric materials. Here we apply the approach to analyze the structural degradation of vaginal topical microbicide films due to water uptake. We implemented transmission imaging of 1-mm diameter film samples loaded into a flow chamber with a 1.5×2 mm field of view. After water was flooded into the chamber, interference images were captured and analyzed to obtain high resolution maps of the local refractive index and subsequently the volume fraction and mass density of film material at each spatial location. Here, we compare the hydration dynamics of a panel of films with varying thicknesses and polymer compositions, demonstrating that quantitative imaging refractometry can be an effective tool for evaluating and characterizing the performance of candidate microbicide film designs for anti-HIV drug delivery. © 2014 Rinehart et al

    Understanding how space travel affects the female reproductive system to the Moon and beyond

    Get PDF
    As the space industry grows exponentially and aspirations for space travel expand, we are entering a new era where we will very likely become an interplanetary species. Although reproduction is an essential human function and necessary for species survival, we have remarkably little knowledge regarding the impact of space travel on the female reproductive system. The effects of spaceflight on human reproductive potential, fertility, implantation and subsequent pregnancy resulting in a healthy live birth must be considered before planning prolonged spaceflight missions and the colonization of planets. In this review, we explore what is known and what remains to be learned about the effects of space travel on female reproductive endocrinology. We also delve deeper into reproductive endocrinology and discuss normal physiologic mechanisms at the molecular level to have a better understanding of how it may change during spaceflight. The rigors of spaceflight including radiation, gravitational stressors, and circadian rhythm changes could potentially affect ovulation, fertilization, endometrial receptivity, preimplantation embryo development, embryo implantation, placentation, and pregnancy. Thus, we will examine what is known about spaceflight effects on the hypothalamic–pituitary–gonadal (HPG) axis, ovarian folliculogenesis and steroidogenesis, early embryogenesis, endometrial receptivity, and pregnancy. We further discuss the recent advances in reproductive endocrinology and future research platforms. Establishing a better understanding of the effect of space travel on female reproductive health, as well as developing countermeasures to mitigate adverse effects, are decisive components of our species’ successful transition to an interplanetary one

    Dry Needling for Spine Related Disorders: a Scoping Review

    Get PDF
    Introduction/Background: The depth and breadth of research on dry needling (DN) has not been evaluated specifically for symptomatic spine related disorders (SRD) from myofascial trigger points (TrP), disc, nerve and articular structures not due to serious pathologies. Current literature appears to support DN for treatment of TrP. Goals of this review include identifying research published on DN treatment for SRD, sites of treatment and outcomes studied. Methods: A scoping review was conducted following Levac et al.’s five part methodological framework to determine the current state of the literature regarding DN for patients with SRD. Results: Initial and secondary search strategies yielded 55 studies in the cervical (C) region (71.43%) and 22 in the thoracolumbar-pelvic (TLP) region (28.57%). Most were randomized controlled trials (60% in C, 45.45% in TLP) and clinical trials (18.18% in C, 22.78% in TLP). The most commonly treated condition was TrP for both the C and TLP regions. In the C region, DN was provided to 23 different muscles, with the trapezius as treatment site in 41.88% of studies. DN was applied to 31 different structures in the TLP region. In the C region, there was one treatment session in 23 studies (41.82%) and 2–6 treatments in 25 (45.45%%). For the TLP region, one DN treatment was provided in 8 of the 22 total studies (36.36%) and 2–6 in 9 (40.9%). The majority of experimental designs had DN as the sole intervention. For both C and TLP regions, visual analogue scale, pressure pain threshold and range of motion were the most common outcomes. Conclusion: For SRD, DN was primarily applied to myofascial structures for pain or TrP diagnoses. Many outcomes were improved regardless of diagnosis or treatment parameters. Most studies applied just one treatment which may not reflect common clinical practice. Further research is warranted to determine optimal treatment duration and frequency. Most studies looked at DN as the sole intervention. It is unclear whether DN alone or in addition to other treatment procedures would provide superior outcomes. Functional outcome tools best suited to tracking the outcomes of DN for SRD should be explored.https://doi.org/10.1186/s12998-020-00310-

    Increasing the packing density of assays in paper-based microfluidic devices

    Get PDF
    Paper-based devices have a wide range of applications in point-of-care diagnostics, environmental analysis, and food monitoring. Paper-based devices can be deployed to resource-limited countries and remote settings in developed countries. Paper-based point-of-care devices can provide access to diagnostic assays without significant user training to perform the tests accurately and timely. The market penetration of paper-based assays requires decreased device fabrication costs, including larger packing density of assays (i.e., closely packed features) and minimization of assay reagents. In this review, we discuss fabrication methods that allow for increasing packing density and generating closely packed features in paper-based devices. To ensure that the paper-based device is low-cost, advanced fabrication methods have been developed for the mass production of closely packed assays. These emerging methods will enable minimizing the volume of required samples (e.g., liquid biopsies) and reagents in paper-based microfluidic device

    Smartphone-based colorimetric detection system for portable health tracking

    No full text
    Colorimetric tests for at-home health monitoring became popular 50 years ago with the advent of the urinalysis test strips, due to their reduced costs, practicality, and ease of operation. However, developing digital systems that can interface these sensors in an efficient manner remains a challenge. Efforts have been put towards the development of portable optical readout systems, such as smartphones. However, their use in daily settings is still limited by their error-prone nature associated to optical noise from the ambient lighting, and their low sensitivity. Here, a smartphone application (Colourine) to readout colorimetric signals was developed on Android OS and tested on commercial urinalysis test strips for pH, proteins, and glucose detection. The novelty of this approach includes two features: a pre-calibration step where the user is asked to take a photo of the commercial reference chart, and a CIE-RGB-to-HSV color space transformation of the acquired data. These two elements allow the background noise given by environmental lighting to be minimized. The sensors were characterized in the ambient light range 100–400 lx, yielding a reliable output. Readouts were taken from urine strips in buffer solutions of pH (5.0–9.0 units), proteins (0–500 mg dL−1) and glucose (0–1000 mg dL−1), yielding a limit of detection (LOD) of 0.13 units (pH), 7.5 mg dL−1 (proteins) and 22 mg dL−1 (glucose), resulting in an average LOD decrease by about 2.8 fold compared to the visual method

    Engineering long shelf life multilayer biologically active surfaces on microfluidic devices for point of care applications

    Get PDF
    Although materials and engineered surfaces are broadly utilized in creating assays and devices with wide applications in diagnostics, preservation of these immuno-functionalized surfaces on microfluidic devices remains a significant challenge to create reliable repeatable assays that would facilitate patient care in resource-constrained settings at the point-of-care (POC), where reliable electricity and refrigeration are lacking. To address this challenge, we present an innovative approach to stabilize surfaces on-chip with multiple layers of immunochemistry. The functionality of microfluidic devices using the presented method is evaluated at room temperature for up to 6-month shelf life. We integrated the preserved microfluidic devices with a lensless complementary metal oxide semiconductor (CMOS) imaging platform to count CD4(+) T cells from a drop of unprocessed whole blood targeting applications at the POC such as HIV management and monitoring. The developed immunochemistry stabilization method can potentially be applied broadly to other diagnostic immunoassays such as viral load measurements, chemotherapy monitoring, and biomarker detection for cancer patients at the POC
    corecore