248 research outputs found

    Multilayer porous ionizer Patent

    Get PDF
    Multilayer porous refractory metal ionizer design with thick, porous, large-grain substrates and thin, porous micron-grain substrate

    Surface ionization studies on refractory metals and metal alloys

    Get PDF
    Surface ionization studies on refractory metals and metal alloys used in long term contact ion engine operatio

    Ion engine supporting research and evaluation. Volume II - Ionization studies Summary report

    Get PDF
    Ionization studies dealing with ion source, emission contamination, and alkali desorption energies on polycrystalline refractory metal

    Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating

    Get PDF
    AIMS: To determine the feasibility of prospective electrocardiogram (ECG)-gating to achieve low-dose computed tomography coronary angiography (CTCA). METHODS AND RESULTS: Forty-one consecutive patients with suspected (n = 35) or known coronary artery disease (n = 6) underwent 64-slice CTCA using prospective ECG-gating. Individual radiation dose exposure was estimated from the dose-length product. Two independent readers semi-quantitatively assessed the overall image quality on a five-point scale and measured vessel attenuation in each coronary segment. One patient was excluded for atrial fibrillation. Mean effective radiation dose was 2.1 +/- 0.6 mSv (range, 1.1-3.0 mSv). Image quality was inversely related to heart rate (HR) (57.3 +/- 6.2, range 39-66 b.p.m.; r = 0.58, P 63 b.p.m. (P < 0.001). CONCLUSION: This first experience documents the feasibility of prospective ECG-gating for CTCA with diagnostic image quality at a low radiation dose (1.1-3.0 mSv), favouring HR <63 b.p.

    Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating

    Get PDF
    AIMS: To determine the feasibility of prospective electrocardiogram (ECG)-gating to achieve low-dose computed tomography coronary angiography (CTCA). METHODS AND RESULTS: Forty-one consecutive patients with suspected (n = 35) or known coronary artery disease (n = 6) underwent 64-slice CTCA using prospective ECG-gating. Individual radiation dose exposure was estimated from the dose-length product. Two independent readers semi-quantitatively assessed the overall image quality on a five-point scale and measured vessel attenuation in each coronary segment. One patient was excluded for atrial fibrillation. Mean effective radiation dose was 2.1 +/- 0.6 mSv (range, 1.1-3.0 mSv). Image quality was inversely related to heart rate (HR) (57.3 +/- 6.2, range 39-66 b.p.m.; r = 0.58, P 63 b.p.m. (P < 0.001). CONCLUSION: This first experience documents the feasibility of prospective ECG-gating for CTCA with diagnostic image quality at a low radiation dose (1.1-3.0 mSv), favouring HR <63 b.p.

    Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience

    Get PDF
    AIMS: To evaluate the accuracy of low-dose computed tomography coronary angiography (CTCA) using prospective ECG-triggering for the assessment of coronary artery disease (CAD). METHODS AND RESULTS: A total of 30 patients (19 males, 11 females, mean age 58.8 +/- 9.9 years) underwent low-dose CTCA and invasive coronary angiography (CA) [median 2 days (0, 41)]. Before CT scanning, intravenous beta-blocker was administered in 18 of 30 patients as heart rate (HR) was >65 b.p.m., achieving a mean HR of 55.7 +/- 7.9 b.p.m. CAD was defined as coronary artery narrowing > or =50%, using CA as standard of reference. The estimated mean effective radiation dose was 2.1 +/- 0.7 mSv (range: 1.0-3.3), yielding 96.0% (383/399) of evaluable segments. On an intention-to-diagnose-base, all non-evaluative segments were included in the analysis. Vessels with a non-evaluative segment and no further finding were censored as false positive. Patient-based analysis revealed sensitivity, specificity, positive predictive value, and negative predictive value of 100, 83.3, 90.0, and 100%, respectively. The respective values per vessel were 100, 88.9, 85.7, and 100%, respectively. CONCLUSION: Prospective ECG-triggering allows low-dose CTCA and provides high diagnostic accuracy in the assessment of CAD in patients with stable sinus rhythm and a low heart rat

    Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: optimized protocol for scan time reduction

    Full text link
    We aimed at establishing the optimal scan time for nuclear myocardial perfusion imaging (MPI) on an ultrafast cardiac gamma-camera using a novel cadmium-zinc-telluride (CZT) solid-state detector technology. METHODS: Twenty patients (17 male; BMI range, 21.7-35.5 kg/m(2)) underwent 1-d (99m)Tc-tetrofosmin adenosine stress and rest MPI protocols, each with a 15-min acquisition on a standard dual-detector SPECT camera. All scans were immediately repeated on an ultrafast CZT camera over a 6-min acquisition time and reconstructed from list-mode raw data to obtain scan durations of 1 min, 2 min, etc., up to a maximum of 6 min. For each of the scan durations, the segmental tracer uptake value (percentage of maximum myocardial uptake) from the CZT camera was compared by intraclass correlation with standard SPECT camera data using a 20-segment model, and clinical agreement was assessed per coronary territory. Scan durations above which no further relevant improvement in uptake correlation was found were defined as minimal required scan times, for which Bland-Altman limits of agreement were calculated. RESULTS: Minimal required scan times were 3 min for low dose (r = 0.81; P < 0.001; Bland-Altman, -11.4% to 12.2%) and 2 min for high dose (r = 0.80; P < 0.001; Bland-Altman, -7.6% to 12.9%), yielding a clinical agreement of 95% and 97%, respectively. CONCLUSION: We have established the minimal scan time for a CZT solid-state detector system, which allows 1-d stress/rest MPI with a substantially reduced acquisition time resulting in excellent agreement with regard to uptake and clinical findings, compared with MPI from a standard dual-head SPECT gamma-camera

    Disorder effects in electronic structure of substituted transition metal compounds

    Get PDF
    Investigating LaNi(1-x)M(x)O3 (M = Mn and Fe), we identify a characteristic evolution of the spectral function with increasing disorder in presence of strong interaction effects across the metal-insulator transition. We discuss these results vis-a-vis existing theories of electronic structure in simultaneous presence of disorder and interaction.Comment: Revtex, 4 pages, 3 postscript figures (To appear in Phys. Rev. Lett

    K^0 pi^0 Sigma^+ and K^*0 Sigma^+ photoproduction off the proton

    Full text link
    The exclusive reactions γp→K∗0Σ+(1189)\gamma p \to K^{*0} \Sigma^+(1189) and γp→K0π0Σ+(1189)\gamma p \to K^{0} \pi^{0}\Sigma^+(1189), leading to the p 4π0\pi^{0} final state, have been measured with a tagged photon beam for incident energies from threshold up to 2.5 GeV. The experiment has been performed at the tagged photon facility of the ELSA accelerator (Bonn). The Crystal Barrel and TAPS detectors were combined to a photon detector system of almost 4π\pi geometrical acceptance. Differential and total cross sections are reported. At energies close to the threshold, a flat angular distribution has been observed for the reaction γp→K0π0Σ+\gamma p\to K^{0} \pi^{0}\Sigma^+ suggesting dominant s-channel production. Σ∗(1385)\Sigma^*(1385) and higher lying hyperon states have been observed. An enhancement in the forward direction in the angular distributions of the reaction γp→K∗0Σ+\gamma p \to K^{*0}\Sigma^+ indicates a tt-channel exchange contribution to the reaction mechanism. The experimental data are in reasonable agreement with recent theoretical predictions.Comment: 11 pages, 13 figures, submitted to EPJ
    • …
    corecore