75 research outputs found

    Prognosis of chronic low back pain: design of an inception cohort study

    Get PDF
    BACKGROUND: Although clinical guidelines generally portray chronic low back pain as a condition with a poor prognosis this portrayal is based on studies of potentially unrepresentative survival cohorts. The aim of this study is to describe the prognosis of an inception cohort of people with chronic low back pain presenting for primary care. METHODS/DESIGN: The study will be an inception cohort study with one year follow-up. Participants are drawn from a cohort of consecutive patients presenting with acute low back pain (less than 2 weeks duration) to primary care clinics in Sydney, Australia. Those patients who continue to experience pain at three months, and are therefore classified as having chronic back pain, are invited to participate in the current study. The cohort will be followed up by telephone at baseline, 9 months and 12 months after being diagnosed with chronic low back pain. Recovery from low back pain will be measured by sampling three different outcomes: pain intensity, interference with function due to pain, and work status. Life tables will be generated to determine the one year prognosis of chronic low back pain. Prognostic factors will be assessed using Cox regression. DISCUSSION: This study will determine the prognosis of chronic non-specific low back pain in a representative cohort of patients sourced from primary care. The results of this study will improve understanding of chronic low back pain, allowing clinicians to provide more accurate prognostic information to their patients

    Group 3 ITI Consensus Report: Patient-reported outcome measures associated with implant dentistry

    Get PDF
    Objectives: The aim of Working Group 3 was to focus on three topics that were assessed using patient-reported outcome measures (PROMs). These topics included the following: (a) the aesthetics of tooth and implant-supported fixed dental prostheses focusing on partially edentulous patients, (b) a comparison of fixed and removable implant-retained prostheses for edentulous populations, and (c) immediate versus early/conventional loading of immediately placed implants in partially edentate patients. PROMs include ratings of satisfaction and oral health-related quality of life (QHRQoL), as well as other indicators, that is, pain, general health-related quality of life (e.g., SF-36). Materials and methods: The Consensus Conference Group 3 participants discussed the findings of the three systematic review manuscripts. Following comprehensive discussions, participants developed consensus statements and recommendations that were then discussed in larger plenary sessions. Following this, any necessary modifications were made and approved. Results: Patients were very satisfied with the aesthetics of implant-supported fixed dental prostheses and the surrounding mucosa. Implant neck design, restorative material, or use of a provisional restoration did not influence patients’ ratings. Edentulous patients highly rate both removable and fixed implant-supported prostheses. However, they rate their ability to maintain their oral hygiene significantly higher with the removable prosthesis. Both immediate provisionalization and conventional loading receive positive patient-reported outcomes. Conclusions: Patient-reported outcome measures should be gathered in every clinical study in which the outcomes of oral rehabilitation with dental implants are investigated. PROMs, such as patients’ satisfaction and QHRQoL, should supplement other clinical parameters in our clinical definition of success

    18F-fluoro-deoxy-glucose focal uptake in very small pulmonary nodules: fact or artifact? Case reports

    Get PDF
    ABSTRACT: BACKGROUND: F-fluoro-deoxy-glucose (18F-FDG) positron emission tomography integrated/combined with computed tomography (PET-CT) provides the best diagnostic results in the metabolic characterization of undetermined solid pulmonary nodules. The diagnostic performance of 18F-FDG is similar for nodules measuring at least 1 cm and for larger masses, but few data exist for nodules smaller than 1 cm. CASE PRESENTATION: We report five cases of oncologic patients showing focal lung 18F-FDG uptake on PET-CT in nodules smaller than 1 cm. We also discuss the most common causes of 18F-FDG false-positive and false-negative results in the pulmonary parenchyma. In patient 1, contrast-enhanced CT performed 10 days before PET-CT did not show any abnormality in the site of uptake; in patient 2, high-resolution CT performed 1 month after PET showed a bronchiole filled with dense material interpreted as a mucoid impaction; in patient 3, contrast-enhanced CT performed 15 days before PET-CT did not identify any nodules; in patients 4 and 5, contrast-enhanced CT revealed a nodule smaller than 1 cm which could not be characterized. The 18F-FDG uptake at follow-up confirmed the malignant nature of pulmonary nodules smaller than 1 cm which were undetectable, misinterpreted, not recognized or undetermined at contrast-enhanced CT. CONCLUSION: In all five oncologic patients, 18F-FDG was able to metabolically characterize as malignant those nodules smaller than 1 cm, underlining that: 18F-FDG uptake is not only a function of tumor size but it is strongly related to the tumor biology; functional alterations may precede morphologic abnormalities. In the oncologic population, especially in higher-risk patients, PET can be performed even when the nodules are smaller than 1 cm, because it might give an earlier characterization and, sometimes, could guide in the identification of alterations missed on CT

    Palaeogenomics of Upper Palaeolithic to Neolithic European hunter-gatherers

    Get PDF
    Modern humans have populated Europe for more than 45,000 years1,2. Our knowledge of the genetic relatedness and structure of ancient hunter-gatherers is however limited, owing to the scarceness and poor molecular preservation of human remains from that period3. Here we analyse 356 ancient hunter-gatherer genomes, including new genomic data for 116 individuals from 14 countries in western and central Eurasia, spanning between 35,000 and 5,000 years ago. We identify a genetic ancestry profile in individuals associated with Upper Palaeolithic Gravettian assemblages from western Europe that is distinct from contemporaneous groups related to this archaeological culture in central and southern Europe4, but resembles that of preceding individuals associated with the Aurignacian culture. This ancestry profile survived during the Last Glacial Maximum (25,000 to 19,000 years ago) in human populations from southwestern Europe associated with the Solutrean culture, and with the following Magdalenian culture that re-expanded northeastward after the Last Glacial Maximum. Conversely, we reveal a genetic turnover in southern Europe suggesting a local replacement of human groups around the time of the Last Glacial Maximum, accompanied by a north-to-south dispersal of populations associated with the Epigravettian culture. From at least 14,000 years ago, an ancestry related to this culture spread from the south across the rest of Europe, largely replacing the Magdalenian-associated gene pool. After a period of limited admixture that spanned the beginning of the Mesolithic, we find genetic interactions between western and eastern European hunter-gatherers, who were also characterized by marked differences in phenotypically relevant variants

    iHOP Web Services Family

    No full text

    Testing the retention of attachments for implant overdentures - validation of an original force measurement system

    No full text
    P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.Zest Anchors Company, Escondido, CA, USAITI foundatio
    corecore