4,514 research outputs found
Optimization of an Electromagnetic Energy Harvesting Device
This paper presents the modeling and optimization of an electromagnetic-based generator for generating power from ambient vibrations. Basic equations describing such generators are presented and the conditions for maximum power generation are described. Two-centimeter scale prototype generators, which consist of magnets suspended on a beam vibrating relative to a coil, have been built and tested. The measured power and modeled results are compared. It is shown that the experimental results confirm the optimization theory
Microelectromechanical systems vibration powered electromagnetic generator for wireless sensor applications
This paper presents a silicon microgenerator, fabricated using standard silicon micromachining techniques, which converts external ambient vibrations into electrical energy. Power is generated by an electromagnetic transduction mechanism with static magnets positioned on either side of a moving coil, which is located on a silicon structure designed to resonate laterally in the plane of the chip. The volume of this device is approximately 100 mm3. ANSYS finite element analysis (FEA) has been used to determine the optimum geometry for the microgenerator. Electromagnetic FEA simulations using Ansoft’s Maxwell 3D software have been performed to determine the voltage generated from a single beam generator design. The predicted voltage levels of 0.7–4.15 V can be generated for a two-pole arrangement by tuning the damping factor to achieve maximum displacement for a given input excitation. Experimental results from the microgenerator demonstrate a maximum power output of 104 nW for 0.4g (g=9.81 m s1) input acceleration at 1.615 kHz. Other frequencies can be achieved by employing different geometries or material
Conceptual Discovery of Educational Resources through Learning Objectives
Περιέχει το πλήρες κείμενοThis poster reports on current work with the NSF-funded Achievement
Standards Network (ASN) to support discovery of educational resources
in digital libraries using conceptual graphs of officially promulgated achievement
standards statements. Conceptual graphs or knowledge maps of achievement
standards reveal the macrostructure of the learning domain modeled by
those standards and support higher-level understanding by teachers and students.
The work builds on the conceptual framework of the AAAS knowledge
maps by providing the means to flexibly define and deploy new relationship
schemas to fit the disparate modeling needs of the nearly 740 learning standards
documents in the ASN repository. Using an RDF-based, node-link representation
of learning goals and the relationships among them, the ASN Knowledge
Map Service will provide the framework to correlate educational resources to
nodes in conceptual models in order to augment more conventional mechanisms
of discovery and retrieval in digital libraries
Critically phase-matched Ti:sapphire-laserpumped deep-infrared femtosecond optical parametric oscillator based on CdSiP2
We report a high-repetition-rate femtosecond optical parametric oscillator (OPO) for the deep-infrared (deep-IR) based on type-I critical phase-matching in CdSiP2 (CSP), pumped directly by a Ti:sapphire laser. Using angle-tuning in the CSP crystal, the OPO can be continuously tuned across 7306–8329 nm (1201–1369 cm−1) in the deep-IR. It delivers up to 18 mW of idler average power at 7306 nm and >7 mW beyond 8000 nm at 80.5 MHz repetition rate, with the spectra exhibiting bandwidths of >150 nm across the tuning range. Moreover, the signal is tunable across 1128–1150 nm in the near-infrared, providing up to 35 mW of average power in ∼266 fs pulses at 1150 nm. Both beams exhibit single-peak Gaussian distribution in TEM00 spatial profile. With an equivalent spectral brightness of ∼5.6×1020photons s−1 mm−2 sr−10.1% BW−1, this OPO represents a viable alternative to synchrotron and supercontinuum sources for deep-IR applications in spectroscopy, metrology, and medical diagnostics.Peer ReviewedPostprint (author's final draft
Femtosecond deep-infrared optical parametric oscillator pumped directly by a Ti:sapphire laser
We report a high-repetition-rate femtosecond optical parametric oscillator (OPO) for the deep-infrared (deep-IR) based on the nonlinear optical crystal, CdSiP2 (CSP), pumped directly by a Ti:sapphire laser, for the first time. By pumping CSP at <1 μm, we have achieved practical output powers at the longest wavelengths generated by any Ti:sapphire-pumped OPO. Using a combination of pump wavelength tuning, type-I critical phase-matching, and cavity delay tuning, we have generated continuously tunable radiation across 6654−8373 nm (1194−1503 cm-1) at 80.5 MHz repetition rate, providing up to 20 mW of average power at 7314 nm and <7 mW beyond 8000 nm, with idler spectra exhibiting bandwidths of 140−180 nm across the tuning range. Moreover, the near-IR signal is tunable across 1127−1192 nm, providing up to 37 mW of average power at 1150 nm. Signal pulses, characterised using intensity autocorrelation, have durations of ∼260–320 fs, with corresponding time-bandwidth product of ∆υ∆τ∼1. The idler and signal output exhibit a TEM00 spatial profile with single-peak Gaussian distribution. With an equivalent spectral brightness of ∼6.68×1020 photons s-1 mm-2 sr-1 0.1% BW-1, this OPO represents a viable table-top alternative to synchrotron and supercontinuum sources for deep-IR applications in spectroscopy, metrology and medical diagnostics.Peer ReviewedPostprint (author's final draft
Direct Restart of a Replication Fork Stalled by a Head-On RNA Polymerase
In vivo studies suggest that replication forks are arrested due to encounters with head-on transcription complexes. Yet, the fate of the replisome and RNA polymerase (RNAP) following a head-on collision is unknown. Here, we find that the E. coli replisome stalls upon collision with a head-on transcription complex, but instead of collapsing, the replication fork remains highly stable and eventually resumes elongation after displacing the RNAP from DNA. We also find that the transcription-repair coupling factor, Mfd, promotes direct restart of the fork following the collision by facilitating displacement of the RNAP. These findings demonstrate the intrinsic stability of the replication apparatus and a novel role for the transcription-coupled repair pathway in promoting replication past a RNAP block
Thermodynamic metrics and optimal paths
A fundamental problem in modern thermodynamics is how a molecular-scale
machine performs useful work, while operating away from thermal equilibrium
without excessive dissipation. To this end, we derive a friction tensor that
induces a Riemannian manifold on the space of thermodynamic states. Within the
linear-response regime, this metric structure controls the dissipation of
finite-time transformations, and bestows optimal protocols with many useful
properties. We discuss the connection to the existing thermodynamic length
formalism, and demonstrate the utility of this metric by solving for optimal
control parameter protocols in a simple nonequilibrium model.Comment: 5 page
An exact quantification of backreaction in relativistic cosmology
An important open question in cosmology is the degree to which the
Friedmann-Lemaitre-Robertson-Walker (FLRW) solutions of Einstein's equations
are able to model the large-scale behaviour of the locally inhomogeneous
observable universe. We investigate this problem by considering a range of
exact n-body solutions of Einstein's constraint equations. These solutions
contain discrete masses, and so allow arbitrarily large density contrasts to be
modelled. We restrict our study to regularly arranged distributions of masses
in topological 3-spheres. This has the benefit of allowing straightforward
comparisons to be made with FLRW solutions, as both spacetimes admit a discrete
group of symmetries. It also provides a time-symmetric hypersurface at the
moment of maximum expansion that allows the constraint equations to be solved
exactly. We find that when all the mass in the universe is condensed into a
small number of objects (<10) then the amount of backreaction in dust models
can be large, with O(1) deviations from the predictions of the corresponding
FLRW solutions. When the number of masses is large (>100), however, then our
measures of backreaction become small (<1%). This result does not rely on any
averaging procedures, which are notoriously hard to define uniquely in general
relativity, and so provides (to the best of our knowledge) the first exact and
unambiguous demonstration of backreaction in general relativistic cosmological
modelling. Discrete models such as these can therefore be used as laboratories
to test ideas about backreaction that could be applied in more complicated and
realistic settings.Comment: 13 pages, 9 figures. Corrections made to Tables IV and
Novel Cemented Technique for Trochanteric Fixation and Reconstruction of the Abductor Mechanism in Proximal and Total Femoral Arthroplasty: An Observational Study
Background: Little evidence exists regarding the clinical outcomes of cemented trochanteric fixation for abductor mechanism reconstruction in proximal or total femoral replacements. Clinical outcomes were assessed for a novel cemented technique for trochanteric fixation in femoral megaprostheses. Methods: A descriptive series of 13 patients who underwent proximal or total femoral arthroplasty from 2016 to 2019 were reviewed. Radiographic trochanteric displacement \u3e 1 cm defined construct failure. A Kaplan-Meier survival analysis was performed to determine survival rates for these cemented constructs. Demographic information was obtained to better characterize the patient population in whom this technique was used. Results: Eleven patients were included (age = 63.6 years; 45.4% females; body mass index = 31.7). Mean time to final radiographic follow-up was 73.8 weeks. Three of 11 (27.2%) patients had construct failure. Overall, survival at 1 year was 81.8%. At 2 years, survival of cemented constructs was 65.5%. More construct failures occurred in patients who sustained a postoperative dislocation than in those who did not (P = .05). Conclusions: This novel cemented trochanteric fixation technique for reconstruction of the abductor mechanism in femoral megaprostheses had 81.8% survival at 1 year postoperatively. While longitudinal comparative studies with larger samples are needed, the cemented technique may provide a viable alternative to traditional cementless methods of trochanteric fixation. Increased construct failure rates after postoperative dislocation highlight the importance of robust abductor reconstruction in these implants
- …