2,654 research outputs found
Divisão Alta do Nervo Isquiático: Duas Variantes Anatómicas Distintas
Introduction: Sciatic nerve variations are relatively common. These variations are often very significant in several fields of Medicine. The purpose of this paper is to present two such variants and discuss their clinical implications. Material and Methods: Three Caucasian cadavers with no prior history of lower limb trauma or surgery were dissected and found to present anatomical variants of the sciatic nerve. Results: In all cases the sciatic nerve divided above the popliteal fossa. In two cases (cadavers 1 and 2) it divided on both sides in the inferior portion of the gluteal region in its two terminal branches: the common fibular and the tibial nerves. In another case (cadaver 3) the sciatic nerve was found to divide inside the pelvis just before coursing the greater sciatic notch. The common fibular nerve exited the pelvis above the pyriformis muscle and then passed along its posterior aspect, while the tibial nerve coursed deep to the pyriformis muscle. Discussion: According to the literature, the anatomical variant described in cadaver 3 is considered relatively rare. This variant can predispose to nerve entrapment and thus to the pyriformis syndrome, sciatica and coccygodynia. The high division of the sciatic nerve, as presented in cadavers 1 and 2, can make popliteal nerve blocks partially ineffective. Conclusion: The anatomical variants associated with a high division of the sciatic nerve, must always be born in mind, as they are relatively prevalent, and have important clinical implications, namely in Anesthesiology, Neurology, Sports Medicine and Surgery
Recommended from our members
Plasmonic-enhanced photocatalysis reactions using gold nanostructured films
This work shows the enhancement of the visible photocatalytic activity of TiO2 NPs film using the localized surface plasmonic resonance of Au nanostructures. We adopted a simple yet effective surface treatment to tune the size distribution, and plasmonic resonance spectrum of Au nanostructured films on glass substrates, by hot plate annealing in air at low temperatures. A hybrid photocatalytic film of TiO2:Au is utilized to catalyse a selective photodegradation reaction of Methylene Blue in solution. Irradiation at the plasmonic resonance wavelength of the Au nanostructures provides more effective photodegradation compared to broadband artificial sunlight of significantly higher intensity. This improvement is attributed to the active contribution of the plasmonic hot electrons injected into the TiO2. The broadband source initiates competing photoreactions in the photocatalyst, so that carrier transfer from the catalyst surface to the solution is less efficient. The proposed hybrid photocatalyst can be integrated with a variety of device architectures and designs, which makes it highly attractive for low-cost photocatalysis applications
Morphometric Analysis of the Extensor Tendons of the Hallux and Potential Implications for Tendon Grafting
Although several tendon sources are available for reconstructive surgical procedures, all have one or more shortcomings. The aim of this work was to evaluate if the extensor tendons of the hallux showed anatomical characteristics that could make them an additional source for tendon grafting procedures.The authors performed a detailed morphometric analysis of the extensor tendons of the hallux in 26 lower limbs in order to evaluate the putative association of anatomical variants with hallux valgus, and to attempt to assess the feasibility of using part of the extensor apparatus of the hallux as a source of tendon for grafting procedures.An accessory extensor hallucis longus ten-don was found in 92.3% of cases. The extensor hallucis brevis tendon length was 10.5 ± 0.6 cm; its width was 0.5 ± 0.1 cm, and its thickness varied between 1-2 mm, making it a potentially good candidate as a source of ten-don grafts. Several anatomical variations were observed, namely the fusion of the tendons of the extensor hallucis brevis and the accessory extensor hallucis longus muscles in the distal part of the foot.This new therapeutic option, if implemented, would possibly increase the supply of autogenous donor tissue for reconstructive procedures, thereby enhancing the reconstructive surgeon’s armamentarium
Sex-specific associations of adiposity with cardiometabolic traits in the UK: A multi-life stage cohort study with repeat metabolomics
Background Sex differences in cardiometabolic disease risk are commonly observed across the life course but are poorly understood and may be due to different associations of adiposity with cardiometabolic risk in females and males. We examined whether adiposity is differently associated with cardiometabolic trait levels in females and males at 3 different life stages. Methods and findings Data were from 2 generations (offspring, Generation 1 [G1] born in 1991/1992 and their parents, Generation 0 [G0]) of a United Kingdom population-based birth cohort study, the Avon Longitudinal Study of Parents and Children (ALSPAC). Follow-up continues on the cohort; data up to 25 y after recruitment to the study are included in this analysis. Body mass index (BMI) and total fat mass from dual-energy X-ray absorptiometry (DXA) were measured at mean age 9 y, 15 y, and 18 y in G1. Waist circumference was measured at 9 y and 15 y in G1. Concentrations of 148 cardiometabolic traits quantified using nuclear magnetic resonance spectroscopy were measured at 15 y, 18 y, and 25 y in G1. In G0, all 3 adiposity measures and the same 148 traits were available at 50 y. Using linear regression models, sex-specific associations of adiposity measures at each time point (9 y, 15 y, and 18 y) with cardiometabolic traits 3 to 6 y later were examined in G1. In G0, sex-specific associations of adiposity measures and cardiometabolic traits were examined cross-sectionally at 50 y. A total of 3,081 G1 and 4,887 G0 participants contributed to analyses. BMI was more strongly associated with key atherogenic traits in males compared with females at younger ages (15 y to 25 y), and associations were more similar between the sexes or stronger in females at 50 y, particularly for apolipoprotein B-containing lipoprotein particles and lipid concentrations. For example, a 1 standard deviation (SD) (3.8 kg/m2) higher BMI at 18 y was associated with 0.36 SD (95% confidence interval [CI] = 0.20, 0.52) higher concentrations of extremely large very-low-density lipoprotein (VLDL) particles at 25 y in males compared with 0.15 SD (95% CI = 0.09, 0.21) in females, P value for sex difference = 0.02. By contrast, at 50 y, a 1 SD (4.8 kg/m2) higher BMI was associated with 0.33 SD (95% CI = 0.25, 0.42) and 0.30 SD (95% CI = 0.26, 0.33) higher concentrations of extremely large VLDL particles in males and females, respectively, P value for sex difference = 0.42. Sex-specific associations of DXA-measured fat mass and waist circumference with cardiometabolic traits were similar to findings for BMI and cardiometabolic traits at each age. The main limitation of this work is its observational nature, and replication in independent cohorts using methods that can infer causality is required. Conclusions The results of this study suggest that associations of adiposity with adverse cardiometabolic risk begin earlier in the life course among males compared with females and are stronger until midlife, particularly for key atherogenic lipids. Adolescent and young adult males may therefore be high priority targets for obesity prevention efforts
A Rare Variation of the Extensor Indicis Proprius Tendon With Important Clinical Implications
Introduction: Anatomical variations of the extensor tendons to the fingers are of great clinical interest, due to the relatively high frequency of tendon injury in clinical practice. Material and methods: During routine dissection of the right upper limb of a 67-year-old female preserved corpse, the extensor indicis proprius (EIP)
muscle belly originated 3 independent tendons, each with a separate fascial sheath, forming a triple EIP tendon.
There was a larger tendon, which occupied a central position, that represented the usual single EIP tendon. In addition, there were two thinner radial and ulnar accessory EIP tendons. The radial-EIP tendon crossed deep
to the extensor digitorum communis (EDC) tendon to the index finger in the distal half of the dorsum of the hand to reach the radial side of the extensor expansion hood of the index finger. Discussion: According to the literature, the frequency of a triple EIP tendon ranges from 0%, to as high as 7%, although most authors do not acknowledge the presence of this variant in their series. This variant of the EIP tendon, in which the radial-EIP terminated laterally to the termination of the tendon of the EDC to the index finger, may be a source of
confusion intraoperatively, as the EIP tendon has traditionally been identified on the basis of its ulnar location with respect to the EDC tendon. Conclusion: The possibility of a triple EIP tendon should certainly be born in mind by all surgeons when performing tendon repairs, tenoplasties or tendon transfers
On faces of the Kunz cone and the numerical semigroups within them
A numerical semigroup is a cofinite subset of the non-negative integers that
is closed under addition and contains 0. Each numerical semigroup with
fixed smallest positive element corresponds to an integer point in a
rational polyhedral cone , called the Kunz cone. Moreover,
numerical semigroups corresponding to points in the same face are known to share many properties, such as the number of minimal
generators. In this work, we classify which faces of contain
points corresponding to numerical semigroups. Additionally, we obtain sharp
bounds on the number of minimal generators of in terms of the dimension of
the face of containing the point corresponding to
Morfologia e Vascularização do Plexo Braquial no Rato Wistar
Introduction: The rat is probably the animal species most widely used in experimental studies on nerve repair. The aim of this work was to contribute to a better understanding of the morphology and blood supply of the rat brachial plexus. Material and Methods: Thirty adult rats were studied regarding brachial plexus morphology and blood supply. Intravascular injection and dissection under an operating microscope, as well as light microscopy and scanning electron microscopy techniques were used to define the microanatomy of the rat brachial plexus and its vessels. Results: The rat brachial plexus was slightly different from the human brachial plexus. The arterial and venous supply to the brachial plexus plexus was derived directly or indirectly from neighboring vessels. These vessels formed dense and interconnected plexuses in the epineurium, perineurium, and endoneurium. Several brachial plexus components were accompanied for a relatively long portion of their length by large and constant blood vessels that supplied their epineural plexus, making it possible to raise these nerves as flaps. Discussion: The blood supply to the rat brachial plexus is not very different from that reported in humans, making the rat a useful animal model for the experimental study of peripheral nerve pathophysiology and treatment. Conclusion: Our results support the homology between the rat and the human brachial plexus in terms of morphology and blood supply. This work suggests that several components of the rat brachial plexus can be used as nerve flaps, including predominantly motor, sensory or mixed nerve fibers. This information may facilitate new experimental procedures in this animal model
Theoretical Study of Fluid Membranes of Spherical Topology with Internal Degrees of Freedom
A theoretical study of vesicles of topological genus zero is presented. The
bilayer membranes forming the vesicles have various degrees of intrinsic
(tangent-plane) orientational order, ranging from smectic to hexatic,
frustrated by curvature and topology. The field-theoretical model for these
`-atic' surfaces has been studied before in the low temperature (mean-field)
limit. Work presented here includes the effects of thermal fluctuations. Using
the lowest Landau level approximation, the coupling between order and shape is
cast in a simple form, facilitating insights into the behaviour of vesicles.
The order parameter contains vortices, whose effective interaction potential is
found, and renormalized by membrane fluctuations. The shape of the phase space
has a counter-intuitive influence on this potential. A criterion is established
whereby a vesicle of finite rigidity may be burst by its own in-plane order,
and an analogy is drawn with flux exclusion from a type-I superconductor.Comment: 34 pages + 4 Postscript figures. Uses RevTe
Image-based view-angle independent cardiorespiratory motion gating and coronary sinus catheter tracking for x-ray-guided cardiac electrophysiology procedures
Determination of the cardiorespiratory phase of the heart has numerous applications during cardiac imaging. In this article we propose a novel view-angle independent near-real time cardiorespiratory motion gating and coronary sinus (CS) catheter tracking technique for x-ray fluoroscopy images that are used to guide cardiac electrophysiology procedures. The method is based on learning CS catheter motion using principal component analysis and then applying the derived motion model to unseen images taken at arbitrary projections, using the epipolar constraint. This method is also able to track the CS catheter throughout the x-ray images in any arbitrary subsequent view. We also demonstrate the clinical application of our model on rotational angiography sequences. We validated our technique in normal and very low dose phantom and clinical datasets. For the normal dose clinical images we established average systole, end-expiration and end-inspiration gating success rates of 100%, 85.7%, and 92.3%, respectively. For very low dose applications, the technique was able to track the CS catheter with median errors not exceeding 1 mm for all tracked electrodes. Average gating success rates of 80.3%, 71.4%, and 69.2% were established for the application of the technique on clinical datasets, even with a dose reduction of more than 10 times. In rotational sequences at normal dose, CS tracking median errors were within 1.2 mm for all electrodes, and the gating success rate was 100%, for view angles from RAO 90° to LAO 90°. This view-angle independent technique can extract clinically useful cardiorespiratory motion information using x-ray doses significantly lower than those currently used in clinical practice
- …