30 research outputs found

    Effect of mattress deflection on CPR quality assessment for older children and adolescents

    Get PDF
    Appropriate chest compression (CC) depth is associated with improved CPR outcome. CCs provided in hospital are often conducted on a compliant mattress. The objective was to quantify the effect of mattress compression on the assessment of CPR quality in children. Methods: A force and deflection sensor (FDS) was used during CPR in the Pediatric Intensive Care Unit and Emergency Department of a children's hospital. The sensor was interposed between the chest of the patient and hands of the rescuer and measured CC depth. Following CPR event, each event was reconstructed with a manikin and an identical mattress/backboard/patient configuration. CCs were performed using FDS on the sternum and a reference accelerometer attached to the spine of the manikin, providing a means to Calculate the mattress deflection. Results: Twelve CPR events with 14,487 CC (11 patients, median age 14.9 years) were recorded and reconstructed: 9 on ICU beds (9296 CC), 3 on stretchers (5191 CC). Measured mean CC depth during CPR was 47 +/- 8 mm on ICU beds, and 45 +/- 7 mm on stretcher beds with overestimation of 13 +/- 4 mm and 4 +/- 1 mm, respectively, due to mattress compression. After adjusting for this, the proportion of CC that met the CPR guidelines decreased from 88.4 to 31.8% on ICU beds (p < 0.001), and 86.3 to 64.7% on stretcher (p < 0.001 The proportion of appropriate depth CC was significantly smaller on ICU beds (p < 0.001). Conclusion: CC conducted on a non-rigid surface may not be deep enough. FDS may overestimate CC depth by 28% on ICU beds, and 10% on stretcher beds

    A Microsoft HoloLens Mixed Reality Surgical Simulator for Patient-Specific Hip Arthroplasty Training

    Get PDF
    Surgical simulation can offer novice surgeons an opportunity to practice skills outside the operating theatre in a safe controlled environment. According to literature evidence, nowadays there are very few training simulators available for Hip Arthroplasty (HA). In a previous study we have presented a physical simulator based on a lower torso phantom including a patient-specific hemi-pelvis replica embedded in a soft synthetic foam. This work explores the use of Microsoft HoloLens technology to enrich the physical patient-specific simulation with the implementation of wearable mixed reality functionalities. Our HA multimodal simulator based on mixed reality using the HoloLens is described by illustrating the overall system, and by summarizing the main phases of the design and development. Finally, we present a preliminary qualitative study with seven subjects (5 medical students, and 2 orthopedic surgeons) showing encouraging results that suggest the suitability of the HoloLens for the proposed application. However, further studies need to be conducted to perform a quantitative test of the registration accuracy of the virtual content, and to confirm qualitative results in a larger cohort of subjects

    Effect of mattress deflection on CPR quality assessment for older children and adolescents

    Get PDF
    Appropriate chest compression (CC) depth is associated with improved CPR outcome. CCs provided in hospital are often conducted on a compliant mattress. The objective was to quantify the effect of mattress compression on the assessment of CPR quality in children. Methods: A force and deflection sensor (FDS) was used during CPR in the Pediatric Intensive Care Unit and Emergency Department of a children's hospital. The sensor was interposed between the chest of the patient and hands of the rescuer and measured CC depth. Following CPR event, each event was reconstructed with a manikin and an identical mattress/backboard/patient configuration. CCs were performed using FDS on the sternum and a reference accelerometer attached to the spine of the manikin, providing a means to Calculate the mattress deflection. Results: Twelve CPR events with 14,487 CC (11 patients, median age 14.9 years) were recorded and reconstructed: 9 on ICU beds (9296 CC), 3 on stretchers (5191 CC). Measured mean CC depth during CPR was 47 +/- 8 mm on ICU beds, and 45 +/- 7 mm on stretcher beds with overestimation of 13 +/- 4 mm and 4 +/- 1 mm, respectively, due to mattress compression. After adjusting for this, the proportion of CC that met the CPR guidelines decreased from 88.4 to 31.8% on ICU beds (p < 0.001), and 86.3 to 64.7% on stretcher (p < 0.001 The proportion of appropriate depth CC was significantly smaller on ICU beds (p < 0.001). Conclusion: CC conducted on a non-rigid surface may not be deep enough. FDS may overestimate CC depth by 28% on ICU beds, and 10% on stretcher beds

    Ordovician palaeogeography with new palaeomagnetic data from the Montagne Noire (Southern France)

    No full text
    A joint palaeomagnetic and Ar-40/Ar-39 study has been performed on two olistolithic blocks from the Cabrieres Wildflysch in the Montagne Noire region of the Massif Central in France. There, andesitic volcanic and volcaniclastic rocks of Llanvirn-Early Caradoc age (ca 470-458 Ma) occur. Despite extensive secondary alteration, destruction of the dominant magnetic mineral phase and Ar-40/Ar-39 whole rock experiments that demonstrate that the volcanic rocks suffered significant argon loss, a positive fold test and the presence of dual polarities suggest that a primary, Ordovician magnetisation has mostly survived. This is one of the few documented cases where the argon system was substantially reset whilst a subordinate set of small, relatively unaltered magnetite grains, probably hosted in silicates, still carry the original, in this case Ordovician, remanence. The new data show that the Montagne Noire region was located at high southerly latitudes (68degrees (+19)/(-15)) during the Mid-Ordovician. This latitude represents the location for NW Gondwana of which the Massif Central was a part. Palaeomagnetic data from all the Central European massifs and terranes demonstrate a close link to the Gondwana Margin during the Lower and Middle Ordovician

    Measurement of Thermal Stress in Cob Packaging Structures

    No full text

    A sternal accelerometer does not impair hemodynamics during piglet CPR

    No full text
    To determine whether the residual weight of a 260 g sternal accelerometer/force feedback device (AFFD) adversely affects hemodynamics during cardiopulmonary resuscitation in a piglet model of ventricular fibrillation cardiac arrest

    Leaning during chest compressions impairs cardiac output and left ventricular myocardial blood flow in piglet cardiac arrest

    No full text
    Complete recoil of the chest wall between chest compressions during cardiopulmonary resuscitation is recommended, because incomplete chest wall recoil from leaning may decrease venous return and thereby decrease blood flow. We evaluated the hemodynamic effect of 10% or 20% lean during piglet cardiopulmonary resuscitation
    corecore