36 research outputs found

    Report on the activity in the nothern crater of Ol Doinyo Lengai, 24th June to 1st July 1988

    Get PDF
    Volume: 7

    Report on activity in the Northern crator of Ol Doinyo Lengai, July 1988 to August 1989

    Get PDF
    Volume: 7

    A Thin Layer Chromatography Densitometric Method for Assay of Folic Acid in Tablets

    Get PDF
    A High Performance Thin Layer Chromatography (HPTLC) method for analysis offolic acid was developed and validated according to ICH and USP guidelines. Thedeveloped method was used for simultaneous qualitative and quantitative analysisof folic acid in tablets. The method was developed using an environmentallyfriendly mobile phase containing ethyl acetate:methanol:ammonia solution(15:15:0.5 v/v/v) on pre-coated HPTLC silica gel 60 F254 glass plates at a detectionwavelength of 280 nm using reflectance absorbance and saturation time of 25 min.Densitometric analysis showed two folic acid products being retained at Rf of 0.27and 0.67 and the area was taken as the sum of the two. The method was specific andno interferences were observed between folic acid peaks and that of the excipients.The calibration curve of folic acid was constructed using both linear andpolynomial regression function in the range of 317.19–761.25 ng/spot both withregression coefficient, r2 of 0.998. The accuracy at nominal concentration of folicacid was found to be 101.05%, % rsd, repeatability and intermediate precisionwere found to be 1.79% and 1.93 respectively. The developed method is thus simple,accurate, and cost effective with good precision and repeatability for the assay offolic acid in tablets which will be particularly useful in resource constrainedcountries.Key words: High performance thin layer chromatography, densitometry, validation, folic aci

    Экспериментальное сравнение интерференционного и автоколлимационного нуль-индикаторов

    Get PDF
    Introduction. At present, measurement of angles with high accuracy is an essential task in various scientific and industrial fields. The goniometer is one of the most widespread high-precision angle measuring devices, which can incorporate various types of null indicators. In turn, null indicators (NI) are based on different operating principles and can be sensitive to external factors that contribute to the measurement error.Aim. Experimental comparison of two NI types: an interference NI with a Koester prism and an autocollimating NI based on a quadrant photodiode.Materials and methods. An experimental setup was assembled, including two NI that could be connected to one goniometer and measure the accumulated angles of one optical polygon under the same conditions.Results. As a result of conducting measurements and performing a cross-calibration procedure, four sets of data were obtained. An analysis of the processed data showed that the difference in the errors of the ring laser when using two NI did not exceed 0.06 arc seconds, being within the margin of random error. At the same time, the difference between the deviations of the reflecting faces from the nominal position for the two faces exceeded this limit, which confirms the effect of deviation of the surface from the plane on angular measurements with different types of null indicators.Conclusion. According to the results obtained, from the random error point of view, the interference null indicator NI showed higher performance, demonstrating the RMS of measured values of 0.02 angular seconds when measured during 25 prism revolutions. At the same time, the autocollimating null indicator NI had an RMS at the level of 0.04 angular seconds when measured during 64 revolutions. Presumably, this may be caused by the installation specifics of NI. It should also be noted that there is no correlation between the statistical characteristics of the reflecting face itself and the difference between its deviations determined by different NI types.Введение. В настоящее время во многих научных и промышленных задачах требуется измерение углов с высокой точностью. Одним из самых распространенных высокоточных углоизмерительных приборов является гониометр, в составе которого могут применяться различные типы нуль-индикаторов (НИ). НИ, в свою очередь, имеют различные принципы работы и по-разному воспринимают некоторые факторы, способные вносить вклад в погрешность измерений.Цель работы. Экспериментальное сравнение двух типов НИ: интерференционного с призмой Кестерса и автоколлимационного на базе квадрантного фотодиода.Материалы и методы. Для достижения поставленной цели была собрана экспериментальная установка, включающая два НИ, которые могут подключаться к одному гониометру и измерять накопленные углы одной многогранной призмы в одинаковых условиях.Результаты. В результате измерений и проведенной процедуры кросс-калибровки были получены 4 набора данных. Анализ обработанных данных показал, что разница погрешностей кольцевого лазера при использовании двух НИ не превысила 0.06'', что находится в пределах случайной погрешности. В то же время, разница между отклонениями отражающих граней от номинального положения для двух граней этот предел превысила, что подтверждает влияние отклонения поверхности от плоскости на угловые измерения с разными типами НИ.Заключение. По результатам эксперимента с точки зрения случайной погрешности интерференционный НИ проявил себя лучше, продемонстрировав СКО измеренных значений 0.02'' при измерениях в ходе 25 оборотов призмы. В то же время автоколлимационный НИ имел СКО на уровне 0.04'' при измерениях в течение 64 оборотов. Предположительно это может быть связано с установкой НИ. Также необходимо отметить, что корреляция между статистическими характеристиками самой отражающей грани и разницей между ее отклонениями, определяемыми разными типами НИ, отсутствует

    InSAR observations of 2007 Tanzania rifting episode reveal mixed fault and dyke extension in an immature continental rift

    Get PDF
    In the early stages of continental rifting, extension takes place by normal faulting, while in mature continental rifts dyke intrusion dominates. Little is known about the nature of the transition between fault-controlled and dyke-controlled extension or about the processes in an intermediate setting. Here, we present observations of the temporal and spatial evolution of surface displacements during the 2007 July 14–August 4 rifting episode in Northern Tanzania, an immature section of the East African Rift. The ground deformation initiated with subsidence that can be attributed to ∼40 cm of normal motion on a NE striking fault. Following July 17, deformation was dominated by the intrusion of ∼7-km-long dyke. Dyke opening increased gradually to a total of ∼2.4 m. From July 21, the collapse of a shallow graben above the fault dominated the near-field displacements. Comparison to the 2007 Dabbahu dyke, Afar, which occurred in a more mature rift, shows an order-of-magnitude scale difference in dyke length. Using numerical models of dyke propagation, we attribute this to the size and depth of the magma chamber; in immature rifts the thick crust and slow spreading rate favour small, deep magma chambers, forming short, buried dykes, whereas in mature rifts the thinner crust and faster spreading rate favour large, shallow magma chambers and long, erupting dykes. Observing the pattern of active processes in the East African Rift is key to understanding the development of rift systems and passive margins elsewhere

    Оптимизация конструкции встречно-штыревого преобразователя кольцевого резонатора на поверхностных акустических волнах

    Get PDF
    Introduction. Previous works considered the frequency characteristics and methods for fixing sensitive elements in the form of a wave ring resonator on surface acoustic waves in a housing made of various materials, as well as the influence of external factors on sensitive elements. It was found that the passband in such a case is sufficiently wide, which can affect adversely signal detection when measuring acceleration using the sensitive element under development. Therefore, it has become relevant to reduce the sensitive element’s bandwidth by changing the design of the interdigitated transducer (IDT).Aim. To demonstrate an optimal topology for an IDT with a low bandwidth, leading to improved signal detection when acceleration affects the sensitive element.Materials and methods. The finite element method and mathematical processing in AutoCAD and in COMSOL Multiphysics.Results. Nine topologies of IDT are proposed. All these types were investigated using the COMSOL Multiphysics software on lithium niobate substrates, which material acts as a sensitive element. The frequency characteristics are presented. The data obtained allowed an optimal design of the ring resonator to be proposed: an IDT with rectangular pins without selective withdrawal.Conclusion. Self-generation in a ring resonator can be performed by withdrawing no more than one pair of IDTs for 10 or more periods. In this case, the withdrawal of IDTs should be uniform. With an increase in the number of IDT withdrawals, the geometry of the ring resonator is violated, and the wave leaves the structure. The presence of a shared bus keeps the surface acoustic wave inside the IDT structure, and the narrowing of the periods towards the inner part of the structure makes it possible to improve the frequency characteristics of the ring resonator on surface acoustic waves.Введение. В предыдущих публикациях авторами рассматривались частотные характеристики и способы закрепления чувствительных элементов в виде волнового кольцевого резонатора на поверхностных акустических волнах в корпусе из различных материалов, а также влияние внешних факторов на чувствительные элементы. При анализе полученных результатов было замечено, что полоса пропускания достаточно широкая, что может отрицательно сказаться на детектировании сигнала при измерении ускорения с помощью разрабатываемого чувствительного элемента. Возникла необходимость уменьшить полосу пропускания чувствительного элемента за счет изменения конструкции встречноштыревого преобразователя (ВШП). Используя компьютерное моделирование COMSOL Multiphysics, было продемонстрировано несколько вариантов ВШП и показано, что эта цель может быть достигнута изменением геометрии штыря ВШП.Цель работы. Продемонстрировать оптимальную топологию ВШП с малой полосой пропускания, что влечет за собой улучшение детектирования сигнала при влиянии ускорения на чувствительный элемент.Материалы и методы. Применение метода конечных элементов и математическая обработка в AutoCAD и COMSOL Multiphysics.Результаты. Предложено 9 типов топологий встречно-штыревых преобразователей. Проведены исследования при помощи программного обеспечения COMSOL Multiphysics вышеуказанных типов ВШП на подложках из ниобата лития, выступающего в качестве материала чувствительного элемента, и представлены частотные характеристики. Проведена оценка полученных данных и сделаны выводы об оптимальной конструкции кольцевого резонатора: наиболее эффективной структурой является ВШП с прямоугольными штырями без селективного изъятия.Заключение. Генерация волны в кольцевом резонаторе может быть выполнена при изъятии не более одной пары ВШП на 10 и более периодов. При этом изъятие ВШП должно быть равномерным. При увеличении количества изъятых ВШП нарушается геометрия кольцевого резонатора и волна покидает конструкцию. Наличие общей шины позволяет удерживать поверхностную акустическую волну внутри конструкции ВШП, а сужение периодов к внутренней части конструкции позволяет улучшить частотные характеристики кольцевого резонатора на поверхностных акустических волнах

    Lakeside View: Sociocultural Responses to Changing Water Levels of Lake Turkana, Kenya

    Get PDF
    corecore