217 research outputs found
Forecasting the action of CAR-T cells against SARS-corona virus-II infection with branching process
The CAR-T cells are the genetically engineered T cells, designed to work specifically for the virus antigens (or other antigens, such as tumour specific antigens). The CAR-T cells work as the living drug and thus provides an adoptive immunotherapy strategy. The novel corona virus treatment and control designs are still under clinical trials. One of such techniques is the injection of CAR-T cells to fight against the COVID-19 infection. In this manuscript, the hypothesis is based on the CAR-T cells, that are suitably engineered towards SARS-2 viral antigen, by the N protein. The N protein binds to the SARS-2 viral RNA and is found in abundance in this virus, thus for the engineered cell research, this protein sequence is chosen as a potential target. The use of the sub-population of T-reg cells is also outlined. Mathematical modeling of such complex line of action can help to understand the dynamics. The modeling approach is inspired from the probabilistic rules, including the branching process, the Moran process and kinetic models. The Moran processes are well recognized in the fields of artificial intelligence and data science. The model depicts the infectious axis âvirusâCAR-T cellsâmemory cellsâ. The theoretical analysis provides a positive therapeutic action; the delay in viral production may have a significant impact on the early stages of infection. Although it is necessary to carefully evaluate the possible side effects of therapy. This work introduces the possibility of hypothesizing an antiviral use by CAR-T cells
Improving the performance of cryogenic calorimeters with nonlinear multivariate noise cancellation algorithms
State-of-the-art physics experiments require high-resolution, low-noise, and low-threshold detectors to achieve competitive scientific results. However, experimental environments invariably introduce sources of noise, such as electrical interference or microphonics. The sources of this environmental noise can often be monitored by adding specially designed âauxiliary devicesâ (e.g. microphones, accelerometers, seismometers, magnetometers, and antennae). A model can then be constructed to predict the detector noise based on the auxiliary device information, which can then be subtracted from the true detector signal. Here, we present a multivariate noise cancellation algorithm which can be used in a variety of settings to improve the performance of detectors using multiple auxiliary devices. To validate this approach, we apply it to simulated data to remove noise due to electromagnetic interference and microphonic vibrations. We then employ the algorithm to a cryogenic light detector in the laboratory and show an improvement in the detector performance. Finally, we motivate the use of nonlinear terms to better model vibrational contributions to the noise in thermal detectors. We show a further improvement in the performance of a particular channel of the CUORE detector when using the nonlinear algorithm in combination with optimal filtering techniques
The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures
The CUORE experiment is the world's largest bolometric experiment. The
detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg.
CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso,
Italy, searching for the neutrinoless double beta decay of 130Te. A large
custom cryogen-free cryostat allows reaching and maintaining a base temperature
of about 10 mK, required for the optimal operation of the detector. This
apparatus has been designed in order to achieve a low noise environment, with
minimal contribution to the radioactive background for the experiment. In this
paper, we present an overview of the CUORE cryostat, together with a
description of all its sub-systems, focusing on the solutions identified to
satisfy the stringent requirements. We briefly illustrate the various phases of
the cryostat commissioning and highlight the relevant steps and milestones
achieved each time. Finally, we describe the successful cooldown of CUORE
Linee guida di prevenzione oncologica - Tabagismo
Linee guida sulla prevenzione oncologica predisposte dal Consiglio sanitario regionale toscano
From bench to bedside: in vitro and in vivo evaluation of a neonate-focused nebulized surfactant delivery strategy.
BACKGROUND:
Non-invasive delivery of nebulized surfactant has been a neonatology long-pursued goal. Nevertheless, the clinical efficacy of nebulized surfactant remains inconclusive, in part, due to the great technical challenges of depositing nebulized drugs in the lungs of preterm infants. The aim of this study was to investigate the feasibility of delivering nebulized surfactant (poractant alfa) in vitro and in vivo with an adapted, neonate-tailored aerosol delivery strategy.
METHODS:
Particle size distribution of undiluted poractant alfa aerosols generated by a customized eFlow-Neos nebulizer system was determined by laser diffraction. The theoretical nebulized surfactant lung dose was estimated in vitro in a clinical setting replica including a neonatal continuous positive airway pressure (CPAP) circuit, a cast of the upper airways of a preterm neonate, and a breath simulator programmed with the tidal breathing pattern of an infant with mild respiratory distress syndrome (RDS). A dose-response study with nebulized surfactant covering the 100-600\u2009mg/kg nominal dose-range was conducted in RDS-modelling, lung-lavaged spontaneously-breathing rabbits managed with nasal CPAP. The effects of nebulized poractant alfa on arterial gas exchange and lung mechanics were assessed. Exogenous alveolar disaturated-phosphatidylcholine (DSPC) in the lungs was measured as a proxy of surfactant deposition efficacy.
RESULTS:
Laser diffraction studies demonstrated suitable aerosol characteristics for inhalation (mass median diameter, MMD\u2009=\u20093\u2009\u3bcm). The mean surfactant lung dose determined in vitro was 13.7%\u2009\ub1\u20094.0 of the 200\u2009mg/kg nominal dose. Nebulized surfactant delivered to spontaneously-breathing rabbits during nasal CPAP significantly improved arterial oxygenation compared to animals receiving CPAP only. Particularly, the groups of animals treated with 200\u2009mg/kg and 400\u2009mg/kg of nebulized poractant alfa achieved an equivalent pulmonary response in terms of oxygenation and lung mechanics as the group of animals treated with instilled surfactant (200\u2009mg/kg).
CONCLUSIONS:
The customized eFlow-Neos vibrating-membrane nebulizer system efficiently generated respirable aerosols of undiluted poractant alfa. Nebulized surfactant delivered at doses of 200\u2009mg/kg and 400\u2009mg/kg elicited a pulmonary response equivalent to that observed after treatment with an intratracheal surfactant bolus of 200\u2009mg/kg. This bench-characterized nebulized surfactant delivery strategy is now under evaluation in Phase II clinical trial (EUDRACT No.:2016-004547-36)
From bench to bedside: In vitro and in vivo evaluation of a neonate-focused nebulized surfactant delivery strategy
Background: Non-invasive delivery of nebulized surfactant has been a neonatology long-pursued goal.
Nevertheless, the clinical efficacy of nebulized surfactant remains inconclusive, in part, due to the great technical
challenges of depositing nebulized drugs in the lungs of preterm infants. The aim of this study was to investigate
the feasibility of delivering nebulized surfactant (poractant alfa) in vitro and in vivo with an adapted, neonate-
tailored aerosol delivery strategy.
Methods: Particle size distribution of undiluted poractant alfa aerosols generated by a customized eFlow-Neos
nebulizer system was determined by laser diffraction. The theoretical nebulized surfactant lung dose was estimated
in vitro in a clinical setting replica including a neonatal continuous positive airway pressure (CPAP) circuit, a cast of
the upper airways of a preterm neonate, and a breath simulator programmed with the tidal breathing pattern of an
infant with mild respiratory distress syndrome (RDS). A dose-response study with nebulized surfactant covering the
100\u2013600 mg/kg nominal dose-range was conducted in RDS-modelling, lung-lavaged spontaneously-breathing
rabbits managed with nasal CPAP. The effects of nebulized poractant alfa on arterial gas exchange and lung
mechanics were assessed. Exogenous alveolar disaturated-phosphatidylcholine (DSPC) in the lungs was measured
as a proxy of surfactant deposition efficacy.
Results: Laser diffraction studies demonstrated suitable aerosol characteristics for inhalation (mass median
diameter, MMD = 3 \u3bcm). The mean surfactant lung dose determined in vitro was 13.7% \ub1 4.0 of the 200 mg/kg
nominal dose. Nebulized surfactant delivered to spontaneously-breathing rabbits during nasal CPAP significantly
improved arterial oxygenation compared to animals receiving CPAP only. Particularly, the groups of animals treated
with 200 mg/kg and 400 mg/kg of nebulized poractant alfa achieved an equivalent pulmonary response in terms of
oxygenation and lung mechanics as the group of animals treated with instilled surfactant (200 mg/kg).
Conclusions: The customized eFlow-Neos vibrating-membrane nebulizer system efficiently generated respirable
aerosols of undiluted poractant alfa. Nebulized surfactant delivered at doses of 200 mg/kg and 400 mg/kg elicited a
pulmonary response equivalent to that observed after treatment with an intratracheal surfactant bolus of 200 mg/kg.
This bench-characterized nebulized surfactant delivery strategy is now under evaluation in Phase II clinical trial
(EUDRACT No.:2016\u2013004547-36)
First search for Lorentz violation in double beta decay with scintillating calorimeters
We present the search for Lorentz violation in the double beta decay of Se-82 with CUPID-0, using an exposure of 9.95 kg x yr. We found no evidence for the searched signal and set a limit on the isotropic components of the Lorentz violating coefficient of (a) over circle ((3))(of) ((3))(of) obtained with a scintillating bolometer, showing the potentiality of this technique
Measurement of the (, Ar) total hadronic cross section at the LArIAT experiment
We present the first measurement of the negative pion total hadronic cross
section on argon, which we performed at the Liquid Argon In A Testbeam (LArIAT)
experiment. All hadronic reaction channels, as well as hadronic elastic
interactions with scattering angle greater than 5~degrees are included. The
pions have a kinetic energies in the range 100-700~MeV and are produced by a
beam of charged particles impinging on a solid target at the Fermilab Test Beam
Facility. LArIAT employs a 0.24~ton active mass Liquid Argon Time Projection
Chamber (LArTPC) to measure the pion hadronic interactions. For this
measurement, LArIAT has developed the ``thin slice method", a new technique to
measure cross sections with LArTPCs. While generally higher than the
prediction, our measurement of the (,Ar) total hadronic cross section is
in agreement with the prediction of the Geant4 model when considering a model
uncertainty of 5.1\%.Comment: 15 pages, 15 figures, 3 tables, accepted by PR
The Liquid Argon In A Testbeam (LArIAT) Experiment
The LArIAT liquid argon time projection chamber, placed in a tertiary beam of
charged particles at the Fermilab Test Beam Facility, has collected large
samples of pions, muons, electrons, protons, and kaons in the momentum range
300-1400 MeV/c. This paper describes the main aspects of the detector and
beamline, and also reports on calibrations performed for the detector and
beamline components
Perspectives of lowering CUORE thresholds with Optimum Trigger
CUORE is a cryogenic experiment that focuses on the search of neutrinoless double beta decay in 130Te and it is located at the Gran Sasso National Laboratories. Its detector consists of 988 TeO2 crystals operating at a base temperature of ~10 mK. It is the first ton-scale bolometric experiment ever realized for this purpose. Thanks to its large target mass and ultra-low background, the CUORE detector is also suitable for the search of other rare phenomena. In particular the low energy part of the spectra is interesting for the detection of WIMP-nuclei scattering reactions. One of the most important requirements to perform these studies is represented by the achievement of a stable energy threshold lower than 10 keV. Here, the CUORE capability to accomplish this purpose using a low energy software trigger will be presented and described
- âŠ