120 research outputs found

    Noncircular Orifice Holes and Advanced Fabrication Techniques for Liquid Rocket Injectors (Phases 1, 2, 3, and 4)

    Get PDF
    A comprehensive summary of the results of a cold-flow and hot-fire experimental study of the mixing and atomization characteristics of injector elements incorporating noncircular orifices is presented. Both liquid/liquid and gas/liquid element types are discussed. Unlike doublet and triplet elements (circular orifices only) were investigated for the liquid/liquid case while concentric tube elements were investigated for the gas/liquid case. It is concluded that noncircular shape can be employed to significant advantage in injector design for liquid rocket engines

    Correlation of spray dropsize distribution and injector variables Interim report

    Get PDF
    Correlation of spray drop size distribution and injector variable

    Experimental verification of computer spray-combustion models

    Get PDF
    Analytical model formulation, representing performance of spray-combustion device, is based on understanding of atomization, mixing, vaporization, and combustion which occurs in device. Report lists results of correlations of computed values with values obtained from experiments with rocket combustor. Technique offers excellent method for evaluating validity and ranges of applicability of combustion models

    Perforated Plates as Passive Mitigation Systems

    Get PDF
    This paper presents the results of tests on fully-clamped circular plates subjected to blastloading directed down a tube. Four series of tests were performed. In one set of experiments,the blast wave was allowed to progress unhindered down the tube to impinge upon the plate,and in the other tests, perforated plates were placed in the path of the blast wave to hinderprogression down the tube, disrupting the blast and absorbing some of the kinetic energy.Results of the tests indicate that the perforated plates can be used as a form of passive mitigation

    Towards Standardising SHPB Testing - A Round Robin Exercise

    Get PDF
    The Split Hopkinson Pressure Bar (SHPB) test, while widely utilised for high strain rate tests, has yet to be standardised. As an exploratory step towards developing a standard test method or protocol, a Round Robin test series has been conducted between four institutions: (i) Swinburne University of Technology, Australia (ii) University of São Paulo, Brazil, (iii) University of Cape Town, South African and (iv) Nanyang Technological University, Singapore. Each institution prepared specimens from a metallic material, and provided batches of specimens from their chosen material to the other institutions. The materials utilised in this round of testing were commercially pure copper and aluminium, magnesium alloy and stainless steel (316 grade). The intent of the first exercise is to establish the consistency of SHPB test results on nominally identical specimens at comparable elevated strain rates, conducted by different laboratories following notionally similar test procedures with some freedom in data processing. This paper presents and compares the results of the first batch of tests for copper, identifying variations between results from different laboratories. The variation between different laboratories’ results for copper is suffciently small that there is confidence in the potential to develop a draft standard in future

    Children and young people's participation training workshop guide

    Get PDF
    This guidance on training in children and young people’s participation (CYPP) was first developed by Development Focus when working with a range of government and non-government organisations in the UK and internationally. It has then been applied and built upon by ChildHope and their local partners in different organisational, political and cultural contexts. Experienced facilitators who work with children and young people in partner organisations were trained and mentored by ChildHope, so that they could plan and deliver children and young people’s participation training to core staff, as well as adults and children from the communities they work in. The training was piloted by ChildHope with their partners Organisation for Child Development and Transformation (CHADET) in Assela, Ethiopia and with Street Child of Sierra Leone in Makeni, Sierra Leone. This training was delivered to staff, men, women, girls and boys for a period of five days and culminated in the development of a local action plan for children and young people’s participation. Experiences were also added during training with Proceso Social, Calandria, Cesip and Amhauta, ChildHope’s partners in Peru

    Decompressive cervical laminectomy and lateral mass screw-rod arthrodesis. Surgical analysis and outcome

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>This study evaluates the outcome and complications of decompressive cervical Laminectomy and lateral mass screw fixation in 110 cases treated for variable cervical spine pathologies that included; degenerative disease, trauma, neoplasms, metabolic-inflammatory disorders and congenital anomalies.</p> <p>Methods</p> <p>A retrospective review of total 785 lateral mass screws were placed in patients ages 16-68 years (40 females and 70 males). All cases were performed with a polyaxial screw-rod construct and screws were placed by using Anderson-Sekhon trajectory. Most patients had 12-14-mm length and 3.5 mm diameter screws placed for subaxial and 28-30 for C1 lateral mass. Screw location was assessed by post operative plain x-ray and computed tomography can (CT), besides that; the facet joint, nerve root foramen and foramen transversarium violation were also appraised.</p> <p>Results</p> <p>No patients experienced neural or vascular injury as a result of screw position. Only one patient needed screw repositioning. Six patients experienced superficial wound infection. Fifteen patients had pain around the shoulder of C5 distribution that subsided over the time. No patients developed screw pullouts or symptomatic adjacent segment disease within the period of follow up.</p> <p>Conclusion</p> <p>decompressive cervical spine laminectomy and Lateral mass screw stabilization is a technique that can be used for a variety of cervical spine pathologies with safety and efficiency.</p

    Experimental measurement of specific impulse distribution and transient deformation of plates subjected to near-field explosive blasts

    Get PDF
    The shock wave generated from a high explosive detonation can cause significant damage to any objects that it encounters, particularly those objects located close to the source of the explosion. Understanding blast wave development and accurately quantifying its effect on structural systems remains a considerable challenge to the scientific community. This paper presents a comprehensive experimental study into the loading acting on, and subsequent deformation of, targets subjected to near-field explosive detonations. Two experimental test series were conducted at the University of Sheffield (UoS), UK, and the University of Cape Town (UCT), South Africa, where blast load distributions using Hopkinson pressure bars and dynamic target deflections using digital image correlation were measured respectively. It is shown through conservation of momentum and Hopkinson-Cranz scaling that initial plate velocity profiles are directly proportional to the imparted impulse distribution, and that spatial variations in loading as a result of surface instabilities in the expanding detonation product cloud are significant enough to influence the transient displacement profile of a blast loaded plate

    Development of a new assessment tool for cervical myelopathy using hand-tracking sensor: Part 1: validity and reliability

    Get PDF
    Purpose To assess the reliability and validity of a hand motion sensor, Leap Motion Controller (LMC), in the 15-s hand grip-and-release test, as compared against human inspection of an external digital camera recording. Methods Fifty healthy participants were asked to fully grip-and-release their dominant hand as rapidly as possible for two trials with a 10-min rest in-between, while wearing a non-metal wrist splint. Each test lasted for 15 s, and a digital camera was used to film the anterolateral side of the hand on the first test. Three assessors counted the frequency of grip-and-release (G-R) cycles independently and in a blinded fashion. The average mean of the three was compared with that measured by LMC using the Bland–Altman method. Test–retest reliability was examined by comparing the two 15-s tests. Results The mean number of G-R cycles recorded was: 47.8 ± 6.4 (test 1, video observer); 47.7 ± 6.5 (test 1, LMC); and 50.2 ± 6.5 (test 2, LMC). Bland–Altman indicated good agreement, with a low bias (0.15 cycles) and narrow limits of agreement. The ICC showed high inter-rater agreement and the coefficient of repeatability for the number of cycles was ±5.393, with a mean bias of 3.63. Conclusions LMC appears to be valid and reliable in the 15-s grip-and-release test. This serves as a first step towards the development of an objective myelopathy assessment device and platform for the assessment of neuromotor hand function in general. Further assessment in a clinical setting and to gauge healthy benchmark values is warranted
    • …
    corecore