104 research outputs found

    FMA+ - a new wildfire danger index for the State of Paraná, Brazil.

    Get PDF
    This research was based on meteorological data and forest fire occurrences in Telêmaco Borba county, Parana State, Brazil. The main objective was to improve the Formula de Monte Alegre (FMA) through the inclusion of the wind speed to the index. The forest fire variables used were the date of occurrence, detection and suppressing time and the burned area. The collected data referred to a period of 5 years, from June 1998 to May 2003. Two exponential models were selected. The selected models used the original fire danger classes but definition of new classes were necessary, to adjust to the new models. The selected models had been analyzed and submitted to a performance analysis, using skill score and the percentages of success. The equation to calculate the new wildfire danger index, incorporating the wind speed is:O presente trabalho foi desenvolvido a partir de dados meteorológicos e de ocorrência de incêndios florestais da região de Telêmaco Borba, estado do Paraná, Brasil. O objetivo consistiu em aperfeiçoar a Fórmula de Monte Alegre por meio da inclusão da variável velocidade do vento no índice. As variáveis referentes aos incêndios florestais foram a data de ocorrência, a hora de início e de término e a área queimada. Os dados se referem a um período de 5 anos, compreendido entre 01/06/1998 e 31/05/2003. Foram selecionados dois modelos exponenciais e, como eles usavam as classes de perigo originais, definidas na Fórmula de Monte Alegre, foi necessária a definição de novas classes, que fossem mais adequadas. Os modelos foram analisados e submetidos à análise de desempenho, utilizando-se o skill score e as porcentagens de sucesso de cada um, permitindo assim a definição do melhor modelo a ser incorporado à Fórmula de Monte Alegre, que passou a ter a seguinte representação

    ESPECIFICAÇÃO DE UM SISTEMA COMPUTACIONAL INTEGRADO DE CONTROLE DE INCÊNDIOS FLORESTAIS

    Get PDF
    The main objectives of this paper were to specify a computational system, using the functional modeling, that allows to calculate the forest fire danger index through the Monte Alegre Formula - FMA and the Modified Monte Alegre Formula - FMA+ and to store information of forest fire occurrence, allowing the generation of danger indices and forest fire occurrence statistics. From the analysis of the problem, the Context Diagram, the Level 1 and Level 2 Data-Flow Diagrams, and the Entity-Relationship Diagram were created, in accordance with the techniques of functional modeling. The process functionalities that will compose the future Integrated Forest Fire Control System was also defined. In the specification of the Conceptual Model the description of the data base in independent way of the Data Base Management System DBMS was carried out. This abstraction in relation to the DBMS allows its implementation in any type of DBMS. In the specification of the Logical Model the description of the data base considering the adoption of a Relational Data Base Management System was made.O objetivo deste trabalho é especificar um sistema computacional, utilizando a modelagem funcional, que permita calcular o índice de perigo de incêndios florestais pela Fórmula de Monte Alegre (FMA) e Fórmula de Monte Alegre Alterada (FMA+) e armazenar informações referentes aos incêndios florestais, permitindo também a geração de estatísticas sobre índices de perigo e ocorrência de incêndios florestais. Após a análise do problema, foram criados o Diagrama de Contexto, os Diagramas de Fluxo de Dados de Nível 1 e de Nível 2 e o Diagrama de Entidade-Relacionamento, de acordo com as técnicas de modelagem funcional e modelagem de dados. Foram definidas as funcionalidades de todos os processos que irão compor o futuro Sistema Integrado de Controle de Incêndios Florestais. Na especificação do Modelo Conceitual, foi feita a descrição do banco de dados de maneira independente do Sistema de Gerenciamento de Banco de Dados (SGBD), permitindo que ele seja implementado em qualquer tipo de SGBD. Na especificação do Modelo Lógico, foi feita a descrição do banco de dados considerando a adoção de um Sistema de Gerenciamento de Banco de Dados Relacional

    AJUSTE DA FÓRMULA DE MONTE ALEGRE ALTERADA (FMA+) PARA O ESTADO DO PARANÁ

    Get PDF
    This study was developed utilizing meteorological and forest fire occurrence data from 10 regions of Paraná state: Cambará, Campo Mourão, Cândido de Abreu, Cascavel, Guarapuava, Londrina, Palmas, Paranavaí, Pinhais and Telêmaco Borba. Collected data reffered to a five year period, from June 1998 to May 2003. The main objective of this research was to adjust the Modified Monte Alegre Formula (FMA+) for the state of Parana, based on the performance analysis of this index using the skill score method. The results showed that three different danger scales should be used in the State. The original danger class scale is to be used in the central state area, represented by the Cândido de Abreu, Cascavel, Guarapuava and Telêmaco Borba regions. A second danger class scale is to be used in the northern area, represented by the Cambará and Paranavaí regions and a third scale validated by the Campo Mourão, Londrina, Palmas and Pinhais regions, should be used in the remaining State areas.O presente trabalho foi desenvolvido a partir de dados meteorológicos e de ocorrência de incêndios florestais das regiões de Cambará, Campo Mourão, Cândido de Abreu, Cascavel, Guarapuava, Londrina, Palmas, Paranavaí, Pinhais e Telêmaco Borba no estado do Paraná. O objetivo consistiu em ajustar a Fórmula de Monte Alegre Alterada (FMA+) para o estado do Paraná estudando o seu desempenho em várias regiões do estado. Os dados meteorológicos referem-se a um período de 5 anos, entre 01/06/1998 e 31/05/2003. Os dados de ocorrências de incêndios foram analisados ao longo de diferentes períodos dentro desses 5 anos. Foram feitas análises de desempenho para a FMA+ em cada região, utilizando-se o método skill score. Os resultados mostraram que a FMA+ deve ter três escalas de perigo distintas para as dez regiões estudadas. A escala de perigo original deve ser utilizada na área central do estado, onde se encontram as regiões de Cândido de Abreu, Cascavel, Guarapuava e Telêmaco Borba. A segunda deve ser utilizada no extremo norte do estado, compreendendo as regiões de Cambará e Paranavaí e a terceira deve ser utilizada para o restante do estado, validada pelas regiões de Campo Mourão, Londrina, Palmas e Pinhais

    ANÁLISE DA FÓRMULA DE MONTE ALEGRE ALTERADA (FMA+) PARA O ESTADO DO PARANÁ

    Get PDF
    This work was developed from meteorological data of 34 regions of the State of the Paraná, supplied for the Instituto Tecnológico Simepar, with the objective to evaluate the performance of the Modified Monte Formula Alegre (FMA+) in the State of the Paraná. It was used meteorological data from 1998 to 2007. The results make evident that the FMA+ preserves the three distinct scales of fire danger for the State of Paraná.O presente trabalho foi desenvolvido a partir de dados meteorológicos de 34 regiões do estado do Paraná, fornecidos pelo Instituto Tecnológico Simepar, com o objetivo de avaliar o desempenho da Fórmula de Monte Alegre Alterada (FMA+) para o estado do Paraná. Foram utilizados dados do período compreendido entre 1998 e 2007. Os resultados mostraram que a FMA+ preserva as três escalas de perigo de incêndio distintas para o estado do Paraná

    PROMETHEUS – SISTEMA COMPUTACIONAL INTEGRADO DE CONTROLE DE INCÊNDIOS FLORESTAIS

    Get PDF
    The main objectives of this paper were to develop a computational system, using the functional modeling, that allows to calculate the forest fire danger index through the Monte Alegre Formula (FMA) and the original, adjusted 1 and adjusted 2 Modified Monte Alegre Formula (FMA+) and to store information of forest fire occurrence. The system also permits the generation of danger indices and forest fire occurrence statistics from the Context Diagram, the Level 1 and Level 2 Data-Flow Diagrams, and the Entity-Relationship. The Prometheus system was developed using the Borland Delphi 6.0 language with Borland Database Engine (BDE) access and Paradox database.O objetivo deste trabalho foi desenvolver um sistema computacional utilizando a modelagem funcional, que permita calcular o índice de perigo de incêndios florestais pela Fórmula de Monte Alegre (FMA) e Fórmula de Monte Alegre Alterada (FMA+) original, Ajuste 1 e Ajuste 2, e armazenar informações referentes às ocorrências de incêndios florestais. O sistema possibilita a geração de estatísticas sobre índices de perigo e incidência de incêndios, a partir do Diagrama de Contexto, dos Diagramas de Fluxo de Dados de Nível 1 e de Nível 2 e do Diagrama de Entidade-Relacionamento. O sistema Prometheus foi desenvolvido usando a linguagem Borland Delphi 6.0 com acesso via Borland Database Engine (BDE) e base de dados Paradox

    Estimative of 1:00 pm relative humidity based on 9:00 am and 3:00 pm data, to Parana state, Brazil

    Get PDF
    This research was based on meteorological data from Cambará, Campo Mourão, Cândido de Abreu, Cascavel, Guarapuava, Londrina, Palmas, Paranavaí and Pinhais regions, Paraná State, Brazil. In order to use Monte Alegre Formula it was necessary to develop equations that estimate the values of Relative Humidity at 13:00 h, from the data of 9:00 and 15:00 h, standard times used in meteorological stations of the Brazilian official network. The meteorological variable used were the relative humidity data at 9:00, 13:00 and 15:00 h. The collected data refer to a period of 5 years, from June 1998 to May 2003. Equations to estimate the 13:00 h relative humidity for each region had to be developed. Equations that presented better fits based on the determination coefficients (R2) and the standard error of residues (sy.x) were submitted to covariance analysis. Similar equations were combined, what generated a general equation that estimates relative humidity at 13:00 h (UR13) based on 9:00 (UR09) data and estimates relative humidity at 13:00 h based on 15:00 (UR15) data to Paraná State. The best equation in the first case was UR13 = e (2,72976 + 0,0162192 UR09) and in the second UR13 = 2,451510 UR15 0,796072.O presente trabalho foi desenvolvido a partir de dados meteorológicos das regiões de Cambará, Campo Mourão, Cândido de Abreu, Cascavel, Guarapuava, Londrina, Palmas, Paranavaí e Pinhais, estado do Paraná. Como a Fórmula de Monte Alegre utiliza para o cálculo do índice de perigo de incêndios florestais a umidade relativa observada às 13:00 h e os padrões das estações meteorológicas da rede oficial de estações convencionais brasileiras são 9:00 e 15:00 h, buscou-se uma alternativa para a utilização do índice a partir desses dados. O objetivo consistiu em desenvolver equações que estimem os valores da Umidade Relativa às 13:00 h, com base nos dados das 9:00 e 15:00 h. Foram utilizados dados de umidade relativa das 9:00, 13:00 e 15:00 h. Os dados se referem a um período de 5 anos, entre 01/06/1998 e 31/05/2003. Foram desenvolvidas equações de regressão para cada região. As equações que apresentaram melhores resultados com base na análise dos coeficientes de determinação (R2) e dos erros-padrão residuais (sy.x) foram submetidas à análise de covariância e aquelas consideradas estatisticamente semelhantes foram combinadas, dando origem a uma equação geral que corrige a umidade relativa das 9:00 (UR09) para as 13:00 h (UR13) e outra que corrige a umidade relativa das 15:00 (UR15) para as 13:00 h para o estado do Paraná. A melhor equação para o primeiro caso foi UR13 = e (2,72976 + 0,0162192 UR09) e a melhor para o segundo caso foi UR13 = 2,451510 UR15 0,796072

    Subsídios à prevenção e combate a incêndios florestais com base no comportamento da precipitação pluviométrica na Floresta Nacional de Irati, Paraná.

    Get PDF
    This research was developed in the Irati National Forest, located predominantly in the county of Fernandes Pinheiro, Paraná State, Brazil, using daily rainfall data from 1963 to 2006. The objective of the study was to examine the precipitation behavior, an important variable in fire occurrence, to use the information in further work on forest fire prevention and control. It was analyzed the monthly precipitation, the number of days with rain, and average daily precipitation, in terms of means, minimum and maximum values. Afterwards, the data were grouped and an analysis of the precipitation evolution for that period was carried out. It was determined and analyzed the inter annual variability of dry and rainy seasons considering the 44 years. Results showed: a) the normal fire season was concentrated from April to August, a period of lower monthly average precipitation; b) an increase in the annual precipitation along the period being studied; c) a decrease in the number of rainy days per year; and d) an increase in the daily average precipitation. It was observed an increase of 128.78 mm in the total annual precipitation, a decrease of approximately 3 days of rain, and an increase of 0.90 mm of average rainfall per day over the period. The beginning of the rain season is concentrated in the first 20 days of September (70.5%). It was observed equivalence between the dry and rain seasons in 1968, 1978 and 1997, what resulted in a forest fire danger increase.Este trabalho foi desenvolvido na Floresta Nacional de Irati localizada, predominantemente, no município de Fernandes Pinheiro, Paraná, com base em dados meteorológicos de precipitação pluviométrica diária, no período de 1963 a 2006. Teve como objetivo analisar os aspectos do comportamento da precipitação, com a finalidade de utilizar esse parâmetro no planejamento de prevenção e combate aos incêndios florestais, em tal unidade de conservação, sobretudo no que diz respeito à definição do período normal de incêndios e sua influência sobre o perigo de incêndios florestais. Foram analisados a precipitação mensal, o número de dias de chuva e a precipitação média por dia de chuva (mm) em termos de seus valores médios, mínimos e máximos, para o período de 1963 a 2005. Posteriormente, esses dados foram agrupados, tendo sido feito um estudo da evolução da precipitação para esses períodos. Foram determinadas e analisadas as variabilidades interanual dos períodos seco e chuvoso, para um período de 44 anos. Observou-se: a) que o período normal de incêndios se concentra nos meses de abril a agosto, período de menor precipitação média mensal; b) um aumento da precipitação anual; c) diminuição no número de dias de chuva por ano; e d) aumento da precipitação média por dia de chuva. Esses aspectos também foram notados quando analisados por períodos, tendo ocorrido o aumento de 128,78 mm na precipitação total anual média; um decréscimo de cerca de 3 dias de chuva e um acréscimo de 0,90 mm de precipitação média por dia de chuva, no período considerado. O início do período das chuvas se concentra nos primeiros 20 dias de setembro (70,5%), tendo sido observado uma equivalência entre os períodos secos e das chuvas em 1968, 1978 e 1997, o que implica em um maior perigo de incêndios florestais

    DESEMPENHO DA FÓRMULA DE MONTE ALEGRE (FMA) E DA FÓRMULA DE MONTE ALEGRE ALTERADA (FMA+) NO DISTRITO FLORESTAL DE MONTE ALEGRE

    Get PDF
    This research was developed in the Monte Alegre Forest District, located in Telêmaco Borba county, Paraná State, Brazil. The meteorological data used in the study was supplied by Klabin S.A., a major Brazilian forest company. Data on forest fire occurrences were collected from June 1998 to May 2003, totalizing 5 years of observation. The main objective of is research was to compare the performance of Monte Alegre Formula (FMA) and Modified Monte Alegre Formula (FMA+) in the fire danger prediction in the Monte Alegre Forest District. The performance of the indices were evaluated through the skill score method, based on a contingency table composed by the observed and the predict values for an event in a determined period of time. Null and Low fire danger classes were considered as indicative of no fire occurrence, whereas Medium, High, and Very High classes were considered as indicative of fire occurrence. Based on these premises the skill score and the success percentages of the indices were calculated. Results indicated a lower performance of the FMA compared to the FMA+ in the analyzed period.Este trabalho foi desenvolvido a partir de dados meteorológicos para o Distrito Florestal de Monte Alegre, localizado no município de Telêmaco Borba, estado do Paraná. A base de dados climatológicos usada foi fornecida pela Klabin S.A. Também foram obtidos dados de ocorrência de incêndios florestais. Os dados de umidade relativa, velocidade do vento, precipitação e de ocorrência de incêndios florestais se referem ao período compreendido entre 01/06/1998 e 31/05/2003, totalizando cinco anos de observação. O objetivo principal da pesquisa foi realizar um estudo comparativo do desempenho da Fórmula de Monte Alegre (FMA) e da Fórmula de Monte Alegre Alterada (FMA+) no Distrito Florestal de Monte Alegre. O desempenho dos índices foi avaliado pelo método skill score. Foram considerados como não indicativos de probabilidade de ocorrência de incêndio as classes de perigo Nulo e Pequeno, e como indicativos de probabilidade de ocorrência as classes de perigo Médio, Alto e Muito Alto. A partir dessa definição, foram calculados os valores de skill score e porcentagens de sucesso dos índices. Os resultados indicaram um desajuste no FMA no período analisado, implicando um desempenho inferior ao desejado, enquanto que FMA+ apresentou desempenho satisfatório, não necessitando de reajuste. Palavras-chave: Índice de perigo de incêndios; incêndios florestais; FMA; FMA+.   Abstract Performance of the Monte Alegre Formula (FMA) and Modified Monte Alegre Formula (FMA+) in the Monte Alegre Forest District .This research was developed in the Monte Alegre Forest District, located in Telêmaco Borba county, Paraná State, Brazil. The meteorological data used in the study was supplied by Klabin S.A., a major Brazilian forest company. Data on forest fire occurrences were collected from June 1998 to May 2003, totalizing 5 years of observation. The main objective of is research was to compare the performance of Monte Alegre Formula (FMA) and Modified Monte Alegre Formula (FMA+) in the fire danger prediction in the Monte Alegre Forest District. The performance of the indices were evaluated through the skill score method, based on a contingency table composed by the observed and the predict values for an event in a determined period of time. Null and Low fire danger classes were considered as indicative of no fire occurrence, whereas Medium, High, and Very High classes were considered as indicative of fire occurrence. Based on these premises the skill score and the success percentages of the indices were calculated. Results indicated a lower performance of the FMA compared to the FMA+ in the analyzed period.Keywords: Fire danger index; forest fires; FMA; FMA+

    Atividade de estudos e investigação sobre o sistema de numeração posicional na formação de professores dos anos iniciais

    Get PDF
    O referido trabalho trata de uma pesquisa que está sendo realizada no âmbito da formação de professores dos anos iniciais. Temos como objetivo questionar o papel e a funcionalidade do Sistema de Numeração Posicional (SNP) na formação didática de professores e assim possibilitar a reconstrução de saberes por meio de respostas espontâneas desses, permitindo o diálogo entre a teoria e a prática em torno dos saberes envolvidos. Para concretização desta, utilizamos os pressupostos teórico-metodológicos da Teoria Antropológico do Didático (TAD), em particular recorremos às Atividades de Estudo e Investigação (AEI) como dispositivo didático em uma turma de Licenciatura Integrada da Universidade Federal do Pará. Temos resultados indicando que as ações desenvolvidas proporcionaram a desnaturalização da noção de base dez e o alargamento do equipamento praxeológico desses futuros professores que passam a ter um olhar crítico para a noção de Sistemas de Numeração

    Climatology of the precipitation behavior in the forest district of Monte Alegre, Paraná.

    Get PDF
    This study was developed utilizing meteorological data of precipitation intensity and number of days of precipitation from 1947 to 2005. Was realized a study of the precipitation in the region, verifying the variation belong the time in the Forest District of Monte Alegre. Were analyzed the intensity of precipitation, number of days of rain and the mean rain per rain-day (mm) in terms of its average, minimum and maximum values and standard deviation, for the period of 1947 to 2005. Later, these data had been grouped in periods of 10 years, having been made a study of the evolution of the precipitation for these periods. A growth in the number of rainy days per year was observed, from decade 1947-1956 for decade 1997-2005. For the decade of 1947-1956 the average number of rainy days was 96,6 days. In the following decade (1957-1966) this value fell for 90,2 days, in the decade of 1987-1996, this value was of 108,6 in the decade of 1997-2005, this value was of 108,1. The results indicate a growth of 11,5 days annual of precipitation.Este trabalho foi desenvolvido a partir de dados meteorológicos de precipitação mensal e número de dias de chuva no período de 1947 a 2005. Foi realizado um estudo do comportamento da precipitação na região do Distrito Florestal de Monte Alegre, verificando sua variação ao longo do tempo. Foram analisados a precipitação média mensal, o número de dias de chuva e a precipitação média por dia de chuva (mm) em termos de seus valores médios, mínimos e máximos e desvio padrão, para o período de 1947 a 2005. Esses dados foram agrupados em períodos de 10 anos, tendo sido feito um estudo da evolução da precipitação para esses períodos. Observou-se um aumento no número de dias de chuva por ano, a partir da década 1947–1956 para a década 1997–2005. Para a década de 1947–1956, o número médio de dias de chuva foi 96,6 dias. Na década seguinte (1957–1966), esse valor caiu para 90,2 dias. Na década de 1987–1996 foi de 108,6, e na década de 1997–2005 esse valor foi de 108,1. Os resultados indicam um crescimento de 11,5 dias anuais de precipitação
    corecore