44 research outputs found
Layered Long Term Co-Culture of Hepatocytes and Endothelial Cells on a Transwell Membrane: Toward Engineering the Liver Sinusoid
This paper presents a novel liver model that mimics the liver sinusoid where most liver activities occur. A key aspect of our current liver model is a layered co-culture of primary rat hepatocytes (PRHs) and primary rat liver sinusoidal endothelial cells (LSECs) or bovine aortic endothelial cells (BAECs) on a transwell membrane. When a layered co-culture was attempted with a thin matrigel layer placed between hepatocytes and endothelial cells to mimic the Space of Disse, the cells did not form completely separated monolayers. However, when hepatocytes and endothelial cells were cultured on the opposite sides of a transwell membrane, PRHs co-cultured with LSECs or BAECs maintained their viability and normal morphology for 39 and 57 days, respectively. We assessed the presence of hepatocyte-specific differentiation markers to verify that PRHs remained differentiated in the long-term co-culture and analyzed hepatocyte function by monitoring urea synthesis. We also noted that the expression of cytochrome P-450 remained similar in the cocultured system from Day 13 to Day 48. Thus, our novel liver model system demonstrated that primary hepatocytes can be cultured for extended times and retain their hepatocyte-specific functions when layered with endothelial cells
An Inkjet Printed Flexible Electrocorticography (ECoG) Microelectrode Array on a Thin Parylene-C Film
Electrocorticography (ECoG) is a conventional, invasive technique for recording brain signals from the cortical surface using an array of electrodes. In this study, we developed a highly flexible 22-channel ECoG microelectrode array on a thin Parylene film using novel fabrication techniques. Narrow (\u3c40 \u3eĀµm) and thin (\u3c500 \u3enm) microelectrode patterns were first printed on PDMS, then the patterns were transferred onto Parylene films via vapor deposition and peeling. A custom-designed, 3D-printed connector was built and assembled with the Parylene-based flexible ECoG microelectrode array without soldering. The impedance of the assembled ECoG electrode array was measured in vitro by electrochemical impedance spectroscopy, and the result was consistent. In addition, we conducted in vivo studies by implanting the flexible ECoG sensor in a rat and successfully recording brain signals
Flow-Induced Voltage Generation Over Monolayer Graphene in the Presence of Herringbone Grooves
While flow-induced voltage over a graphene layer has been reported, its origin remains unclear. In our previous study, we suggested different mechanisms for different experimental configurations: phonon dragging effect for the parallel alignment and an enhanced out-of-plane phonon mode for the perpendicular alignment (Appl. Phys. Lett. 102:063116, 2011). In order to further examine the origin of flow-induced voltage, we introduced a transverse flow component by integrating staggered herringbone grooves in the microchannel. We found that the flow-induced voltage decreased significantly in the presence of herringbone grooves in both parallel and perpendicular alignments. These results support our previous interpretation
Liver Sinusoid on a Chip: Long-Term Layered Co-Culture of Primary Rat Hepatocytes and Endothelial Cells in Microfluidic Platforms
We describe the generation of microfluidic platforms for the co-culture of primary hepatocytes and endothelial cells; these platforms mimic the architecture of a liver sinusoid. This paper describes a progressional study of creating such a liver sinusoid on a chip system. Primary rat hepatocytes (PRHs) were co-cultured with primary or established endothelial cells in layers in single and dual microchannel configurations with or without continuous perfusion. Cell viability and maintenance of hepatocyte functions were monitored and compared for diverse experimental conditions. When primary rat hepatocytes were co-cultured with immortalized bovine aortic endothelial cells (BAECs) in a dual microchannel with continuous perfusion, hepatocytes maintained their normal morphology and continued to produce urea for at least 30 days. In order to demonstrate the utility of our microfluidic liver sinusoid platform, we also performed an analysis of viral replication for the hepatotropic hepatitis B virus (HBV). HBV replication, as measured by the presence of cell-secreted HBV DNA, was successfully detected. We believe that our liver model closely mimics the in vivo liver sinusoid and supports long-term primary liver cell culture. This liver model could be extended to diverse liver biology studies and liver-related disease research such as drug induced liver toxicology, cancer research, and analysis of pathological effects and replication strategies of various hepatotropic infectious agents
The Physical Foundation of Vasoocclusion in Sickle Cell Disease
AbstractThe pathology of sickle cell disease arises from the occlusion of small blood vessels because of polymerization of the sickle hemoglobin within the red cells. We present measurements using a microfluidic method we have developed to determine the pressure required to eject individual red cells from a capillary-sized channel after the cell has sickled. We find that the maximum pressure is only ā¼100 Pa, much smaller than typically found in the microcirculation. This explains why experiments using animal models have not observed occlusion beginning in capillaries. The magnitude of the pressure and its dependence on intracellular concentration are both well described as consequences of sickle hemoglobin polymerization acting as a Brownian ratchet. Given the recently determined stiffness of sickle hemoglobin gels, the observed obstruction seen in sickle cell disease as mediated by adherent cells can now be rationalized, and surprisingly suggests a window of maximum vulnerability during circulation of sickle cells
Layered Hepatocytes and Endothelial Cells on a Transwell Membrane: Toward Engineering the Liver Sinusoid
This paper presents a novel liver model that mimics the liver sinusoid where most liver activities occur. A key aspect of our current liver model is a layered co-culture of primary rat hepatocytes (PRHs) and primary rat liver sinusoidal endothelial cells (LSECs) or bovine aortic endothelial cells (BAECs) on a transwell membrane. When a layered co-culture was attempted with a thin Matrigel layer placed between hepatocytes and endothelial cells to mimic the space of Disse, the cells did not form completely separated monolayers. However, when hepatocytes and endothelial cells were cultured on the opposite sides of a transwell membrane, PRHs co-cultured with LSECs or BAECs maintained their viability and normal morphology for 39 and 57 days, respectively. We assessed the presence of hepatocyte-speciļ¬c differentiation markers to verify that PRHs remained differentiated in the long-term co-culture and analyzed hepatocyte function by monitoring urea synthesis. We also noted that the expression of cytochrome P-450 remained similar in the co-cultured system from day 1 to day 48. Thus, our novel liver model system demonstrated that primary hepatocytes can be cultured for extended times and retain their hepatocyte-speciļ¬c functions when layered with endothelial cells
Magnetically actuated micropumps using an Fe-PDMS composite membrane
Proceedings SPIE International Society for Optical Engineering 6172 (2006). Retrieved April 2006 from http://mems.mem.drexel.edu/actuator.pdfIn this paper we describe a novel Fe-PDMS composite that can be used to create magnetically actuated polymeric
microstructures. The composite is formed by suspending <10Ī¼m iron particles in polydimethylsiloxane (PDMS) at
concentrations ranging from 25-75% by weight. Material properties and processing capabilities have been examined,
and to demonstrate the usefulness of this material we have designed, fabricated and tested two prototypical micropumps
that utilize an Fe-PDMS actuator membrane
Harnessing the Wisdom in Colloidal Chemistry to Make Stable Single-Atom Catalysts
Research on singleāatom catalysts (SACs), or atomically dispersed catalysts, has been quickly gaining momentum over the past few years. Although the unique electronic structure of singly dispersed atoms enables uncommonāsometimes exceptionalāactivities and selectivities for various catalytic applications, developing reliable and general procedures for preparing stable, active SACs in particular for applications under reductive conditions remains a major issue. Herein, the challenges associated with the synthesis of SACs are highlighted semiquantitatively and three stabilization techniques inspired by colloidal science including steric, ligand, and electrostatic stabilization are proposed. Some recent examples are discussed in detail to showcase the power of these strategies in the synthesis of stable SACs without compromising catalytic activity. The substantial further potential of steric, ligand, and electrostatic effects for developing SACs is emphasized. A perspective is given to point out opportunities and remaining obstacles, with special attention given to electrostatic stabilization where little is done so far. The stabilization strategies presented herein have a wide applicability in the synthesis of a series of new SACs with improved performances
Parylene Microcolumn for Miniature Gas Chromatograph
This research contributes to worldwide efforts to miniaturize one of the most powerful and versatile analytical tools, gas chromatography (GC). If a rapid, sensitive and selective hand-held GC system is realized, it would have a wide range of applications in many industries and research areas. As a part of developing a hand-held GC system, this research focuses on the separation column, which is the most important component of a GC system. This thesis describes the development of a miniature separation column that has low thermal mass and an embedded heating element for rapid thermal cycling. The worlds first thin polymer film (parylene) GC column has been successfully developed. This thesis includes: first, a study of theoretical column performance of rectangular GC column; second, the design optimization of parylene column and embedded heating element; third, the development of new processes such as parylene micromolding and stationary phase coating technique for parylene column; fourth, the fabrication of parylene GC column with an embedded heating element; and lastly, the testing and evaluation of parylene GC column through GC analysis.Ph.D.Committee Chair: Peter J. Hesketh; Committee Member: Boris Mizaikoff; Committee Member: Bruno Frazier; Committee Member: Wenjing Ye; Committee Member: Yogendra Josh