165 research outputs found

    Integration of education for sustainability in the preschool curriculum: A comparative study between the two latest Swedish curricula

    Get PDF
    The aim of this study is to provide a content analysis of the new Swedish preschool curriculum in comparison with the previous preceding curriculum to investigate how sustainability and education for sustainability (EfS) have been described, and whether there have been any changes in terms of the scope of their inclusion in the new curriculum. The study adopts a holistic view of sustainability, meaning that the environmental dimension, social dimension, and economic dimension, along with a pluralistic and transformative view of EfS, form the analytical framework. Using content analysis, the frequency of explicit and implicit descriptive words for sustainability and EfS in both curricula were investigated. A contextual analysis was also conducted that involved an interpretation of the meaning of the implicit words. Two main findings could be identified in the new curriculum in comparison to the previous curriculum. The first was that the term sustainability is now used from an explicit and holistic perspective that includes all three dimensions. The second was that the new curriculum provides guidance as to how to incorporate EfS where such words as investigating, participation, collaborate and develop are used. Together with the context in which these words appear, a picture forms of a pluralistic teaching tradition in preschool curricula. Overall, the analysis provides a picture of change in the Swedish preschool curriculum that is in line with the intentions of international policy and research relating to a need for increased focus on sustainability and EfS

    Analysis of haptoblobin in bovine sera using surface plasmon resonance biosensor technique

    Get PDF
    The concentration of acute phase proteins in serum is altered as a response to inflammation, infection or trauma. this makes these proteins potential biomarkers of unspecific pathological processes. In cattle, haptoglobin and serum amyloid A are the two acute phase proteins that show the largest increase in serum concentration as a result of inflammatory processes. The haptoglobin concentration has been shown to correlate to clinical signs as well as inflammatory processes found at post mortem examination. This feature could be useful prognosis of the individual as well as for monitoring the health status of a herd or identifying carcasses that shold be examined closer at the slaughter-house. In this paper, a method for analysis of haptoglobin in milk has been modified for use with bovine sera. The method which uses optical biosensor technology is based on the haemoglobin binding properties of haptoglobin. It utilizes the interaction between analyte (haemoglobin) and biological ligand (haptogobin) which results in an optically detectable alteration in mass on the sensor surface.Serumkoncentrationen av akutfasproteiner förändras som svar på inflammation, infektion eller trauma, vilket gör dem till potentiella biomarkörer för ospecifika sjukdomstillstånd. Hos nötkreatur är haptoglobin och serumamyloid A de akutfasproteiner som visar kraftigast ökning vid inflammatoriska tillstånd. Haptoglobinkoncentrationen har också visats korrelera med kliniska symptom och inflammatoriska förändringar funna vid obduktion. Detta skulle kunna användas för att ställa prognos på individnivå men även för övervakning av hälsoläge i besättningar samt på slakteri för selektion av slaktkroppar som bör undersökas noggrannare. I detta arbete beskrivs hur en metod för analys av haptoglobin i mjölk anpassats för analys av haptoglobin i bovint serum. Metoden utnyttjar haptoglobinets hemoglobinbindande egenskaper och är utvecklad med hjälp av optisk biosensorteknik. Grunden för analysen är en interaktion mellan analyt (hemoglobin) och biologisk ligand (haptoglobin) vilken resulterar i en optiskt detekterbar förändrad massa på sensorytan

    Cancer incidence in relatives of a population-based set of cases of early-onset breast cancer with a known BRCA1 and BRCA2 mutation status

    Get PDF
    BACKGROUND: Relatives of breast cancer cases have an increased risk of the disease. The risk increases with increasing numbers and decreasing age of onset of affected relatives. In families with a BRCA1 or a BRCA2 mutation, individual carrier status predicts the risk of breast cancer. In relatives of cases where both BRCA1 and BRCA2 mutations are excluded, the risk remains undetermined. METHODS: Standardized incidence ratios (SIRs) and cumulative cancer incidences were calculated for relatives of a population-based set of early-onset breast cancer index cases (younger than age 41 years) with a defined BRCA mutation status (n = 203). RESULTS: In first-degree relatives (FDRs) of mutation-negative cases, breast cancer incidences (SIR = 2.3), prostate cancer incidences (SIR = 1.7), cervix cancer incidences (SIR = 3.3) and nonmelanoma skin cancer incidences (SIR = 2.8) were increased. The risks of breast cancer, prostate cancer and nonmelanoma skin cancer were further increased in FDRs of breast cancer cases younger than 36 years of age. In high-risk individuals with at least one relative with breast cancer apart from the index case, but no BRCA mutation in the family, breast cancer incidence was increased (SIR = 5.3); again the prostate cancer incidence was elevated (SIR = 2.5). The cumulative incidence of breast cancer at ages 50 and 70 years for FDRs of index cases without a BRCA mutation was 3.6% and 12.8%, respectively. Similarly, the cumulative incidence of breast cancer for high-risk women was 6.3% and 21.1% at ages 50 and 70 years, and that for FDRs of BRCA mutation carriers was 17.2% and 27.7% at the same ages. CONCLUSION: The incidence of breast cancer is increased for FDRs of women with early-onset breast cancer irrespective of the BRCA status in the family. Risk increases with decreasing age and with increasing number of affected relatives. The incidences of prostate cancer, cervix cancer and nonmelanoma skin cancer are elevated for FDRs of early-onset breast cancer cases without a BRCA mutation, indicating a possible association between these cancers and early-onset breast cancer

    Ligation of the spermatic cord in dogs with a self-locking device of a resorbable polyglycolic based co-polymer

    Get PDF
    Background: New surgical techniques are developed to enable a quicker, easier and safer surgery with reduced risk of complications and shortened time needed for recovery. A resorbable device, a self-locking loop, was designed for surgical ligation. The objective of this pilot study was to investigate the feasibility of ligating the spermatic cord with the device, its biocompatibility and long-term resorption in dogs.  Results: The device was made of a block co-polymer (glycolide and trimethylene carbonate), manufactured by injection moulding and consisted of a flexible band running through a case with a locking mechanism. Ten devices were tested for ligation of the spermatic cords in five dogs admitted for routine neutering. The dogs were monitored by physical examination and ultrasonography of the site of ligation, area of spermatic cord and medial iliac lymph nodes regularly until no hyperechoic remnants of the device or acoustic shadowing or local tissue reactions were observed. Haemostasis of the spermatic cords was achieved with the devices. On ultrasonography the devices were seen as hyperechoic structures for 2 months after neutering causing acoustic shadowing for 1 month. The dogs were monitored for 3 - 5 months after surgery. Gradual decrease in echogenicity and final disappearance of the hyperechoic structures suggested resorption. Macroscopic and histological post mortem examinations were performed in one dog at 3 months after surgery. Post mortem examination showed a tissue reaction of a suture granuloma that was restricted in extent at site of the device.  Conclusions: The results of this pilot study suggest biocompatibility and indicate that ligation of the spermatic cord is feasible with the device

    TOM matcher results for OAEI 2021

    Get PDF
    This paper presents the matching system TOM together with its results in the Ontology Alignment Evaluation Initiative 2021 (OAEI 2021). This is the first participation of TOM in the OAEI. Very recently, transformers achieved remarkable results in the natural language processing community on a variety of tasks. The TOM matching system exploits a zero-shot transformer-based language model to calculate confidences for each instance. The matcher uses the pre-trained transformer model paraphrase-TinyBERT-L6-v2

    High risk of in-breast tumor recurrence after BRCA1/2-associated breast cancer

    Get PDF
    The purpose of the study was to compare breast-conserving therapy (BCT) and mastectomy (M) in BRCA1/2 mutation carriers. Women with invasive breast cancer and a pathogenic mutation in BRCA1 or BRCA2 were included in the study (n = 162). Patients treated with BCT (n = 45) were compared with patients treated with M (n = 118). Endpoints were local recurrence as first recurrence (LR), overall survival (OS), breast cancer death, and distant recurrence. Cumulative incidence was calculated in the presence of competing risks. For calculation of hazard ratios and for multivariable analysis, cause-specific Cox proportional hazards regression was used. Compared to M, BCT was associated with an increased risk of LR in univariable analysis (HR 4.0; 95 % CI 1.6-9.8) and in multivariable analysis adjusting for tumor stage, age, and use of adjuvant chemotherapy (HR 2.9; CI 1.1-7.8). Following M, all local recurrences were seen in the first 5 years after breast cancer diagnosis. Following BCT, the rate of LR continued to be high also after the first 5 years. The cumulative incidence of LR in the BCT group was 15, 25, and 32 % after 5, 10, and 15 years, respectively. There were no significant differences between BCT and M for OS, breast cancer death, or distant recurrence. BRCA1/2 mutation carriers treated with BCT have a high risk of LR, many of which are new primary breast cancers. This must be thoroughly discussed with the patient and is an example of how rapid treatment-focused genetic testing could influence choice of treatment

    High risk of in-breast tumor recurrence after BRCA1/2-associated breast cancer.

    Get PDF
    To access publisher's full text version of this article click on the hyperlink at the bottom of the pageThe purpose of the study was to compare breast-conserving therapy (BCT) and mastectomy (M) in BRCA1/2 mutation carriers. Women with invasive breast cancer and a pathogenic mutation in BRCA1 or BRCA2 were included in the study (n = 162). Patients treated with BCT (n = 45) were compared with patients treated with M (n = 118). Endpoints were local recurrence as first recurrence (LR), overall survival (OS), breast cancer death, and distant recurrence. Cumulative incidence was calculated in the presence of competing risks. For calculation of hazard ratios and for multivariable analysis, cause-specific Cox proportional hazards regression was used. Compared to M, BCT was associated with an increased risk of LR in univariable analysis (HR 4.0; 95 % CI 1.6-9.8) and in multivariable analysis adjusting for tumor stage, age, and use of adjuvant chemotherapy (HR 2.9; CI 1.1-7.8). Following M, all local recurrences were seen in the first 5 years after breast cancer diagnosis. Following BCT, the rate of LR continued to be high also after the first 5 years. The cumulative incidence of LR in the BCT group was 15, 25, and 32 % after 5, 10, and 15 years, respectively. There were no significant differences between BCT and M for OS, breast cancer death, or distant recurrence. BRCA1/2 mutation carriers treated with BCT have a high risk of LR, many of which are new primary breast cancers. This must be thoroughly discussed with the patient and is an example of how rapid treatment-focused genetic testing could influence choice of treatment.Regional Ethical Review Board in Lund Skane County Counsil's Research and Development Foundation Swedish Breast Cancer Association (BRO) Swedish Cancer Society BioCAR

    Induced Terpene Accumulation in Norway Spruce Inhibits Bark Beetle Colonization in a Dose-Dependent Manner

    Get PDF
    Background: Tree-killing bark beetles (Coleoptera, Scolytinae) are among the most economically and ecologically important forest pests in the northern hemisphere. Induction of terpenoid-based oleoresin has long been considered important in conifer defense against bark beetles, but it has been difficult to demonstrate a direct correlation between terpene levels and resistance to bark beetle colonization. Methods: To test for inhibitory effects of induced terpenes on colonization by the spruce bark beetle Ips typographus (L.) we inoculated 20 mature Norway spruce Picea abies (L.) Karsten trees with a virulent fungus associated with the beetle, Ceratocystis polonica (Siem.) C. Moreau, and investigated induced terpene levels and beetle colonization in the bark. Results: Fungal inoculation induced very strong and highly variable terpene accumulation 35 days after inoculation. Trees with high induced terpene levels (n = 7) had only 4.9% as many beetle attacks (5.1 vs. 103.5 attacks m22) and 2.6% as much gallery length (0.029 m m22 vs. 1.11 m m22) as trees with low terpene levels (n = 6). There was a highly significant rank correlation between terpene levels at day 35 and beetle colonization in individual trees. The relationship between induced terpene levels and beetle colonization was not linear but thresholded: above a low threshold concentration of ,100 mg terpene g21 dry phloem trees suffered only moderate beetle colonization, and above a high threshold of ,200 mg terpene g21 dry phloem trees were virtually unattacked. Conclusion/Significance: This is the first study demonstrating a dose-dependent relationship between induced terpenes and tree resistance to bark beetle colonization under field conditions, indicating that terpene induction may be instrumental in tree resistance. This knowledge could be useful for developing management strategies that decrease the impact of tree-killing bark beetles

    Ligation of the mesovarium in dogs with a self-locking implant of a resorbable polyglycolic based co-polymer: a study of feasibility and comparison to suture ligation

    Get PDF
    Background Ligation of the mesovarium in female dogs may be cumbersome with risk of complications and is associated with intense noxious stimuli. A resorbable implant, a self-locking loop designed for surgery, was developed as an alternative to traditional ligation. The study aimed to test the feasibility of ligating the canine ovarian pedicle with the implant and to compare its performance to traditional suture ligation. Results In total 45 intact female dogs destined for elective ovariohysterectomy and adoption were included. In 21 dogs the new resorbable implant was used to ligate the mesovarium, and in 24 control dogs traditional suture was used with one encircling ligature. Mean weight of implant dogs was 10.7±5.6kg (range 3.5–22.0), and mean weight of control dogs was 12.8±6.4kg, (range 4.1–27.0). The body weight of dogs did not differ between groups (P=0.25). In total, 42 ovarian pedicles were successfully ligated with the implant. In one control dog, intraoperative haemorrhage from the left ovarian pedicle was diagnosed. The mesovarium was re-ligated and haemostasis was confirmed. All dogs recovered uneventfully. The ligation time of the mesovarium was significantly shortened (P=0.02) by using the self-locking implant versus a single ligature (3′28′′±1′05′′ and 5′29′′±3′54′′, respectively). Total duration of surgery differed between the groups (P=0.02) with a shortened duration of surgery when using the self-locking implant (15′56′′±2′47′′ and 20′39′′±8′58′′, study group versus control group, respectively). In both groups, duration of surgery and time required to ligate the ovarian pedicle were longer in larger dogs than smaller dogs. Conclusion The results of this feasibility study suggested the implant can be used to ligate the canine mesovarium. Compared with traditional suture ligation, the results suggested that time to ligate the ovarian pedicle and duration of surgery were significantly reduced with the implant. More time was required to perform surgeries in larger dogs

    A new resorbable device for ligation of blood vessels - A pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>During surgery, controlled haemostasis to prevent blood loss is vital for a successful outcome. It can be difficult to ligate vessels located deep in the abdomen. A device that is easy to use and enables secure ligatures could be beneficial. Cable ties made of nylon have been used for ligation but the non-resorbable material caused tissue reactions. The objective of this study was to use a resorbable material to construct a device with a self-locking mechanism and to test its mechanical strength and ligation efficiency.</p> <p>Methods</p> <p>The device was manufactured by injection moulding of polydioxanone, a resorbable polymer used for suture materials. Polydioxanone with inherent viscosities of 1.9 dL/g and 1.3 dL/g were tested. The device consisted of a perforated flexible band which could be pulled through a case with a locking mechanism. After a first version of the device had been tested, some improvements were made. The locking case was downsized, corners were rounded off, the band was made thicker and the mould was redesigned to produce longer devices. Tensile tests were performed with the second version.</p> <p>The first version of the device was used to ligate the ovarian pedicle in a euthanized dog and to test echogenicity of the device with ultrasound. Compression of vessels of the ovarian pedicle was examined by histology. Both versions of the device were tested for haemostasis of and tissue grip on renal arteries in six anaesthetised pigs.</p> <p>Results</p> <p>The tensile strength of the flexible band of the devices with inherent viscosity of 1.9 dL/g was 50.1 ± 5.5 N (range 35.2-62.9 N, <it>n </it>= 11) and the devices with inherent viscosity of 1.3 dL/g had a tensile strength of 39.8 ± 8.1 N (range 18.6-54.2 N, <it>n </it>= 11). Injection moulding of the polymer with lower inherent viscosity resulted in a longer flow distance.</p> <p>Both versions of the device had an effective tissue grip and complete haemostasis of renal arteries was verified. The device attached to the ovarian pedicle could be seen with ultrasound, and vessel compression and occlusion were verified by histology.</p> <p>Conclusions</p> <p>Tests of functionality of the device showed complete haemostasis and good tissue grip. Devices with a band of sufficient length were easily applied and tightened in tissue.</p
    corecore