680 research outputs found

    Physics of ion beam cancer therapy: a multi-scale approach

    Full text link
    We propose a multi-scale approach to understand the physics related to ion-beam cancer therapy. It allows the calculation of the probability of DNA damage as a result of irradiation of tissues with energetic ions, up to 430 MeV/u. This approach covers different scales, starting from the large scale, defined by the ion stopping, followed by a smaller scale, defined by secondary electrons and radicals, and ending with the shortest scale, defined by interactions of secondaries with the DNA. We present calculations of the probabilities of single and double strand breaks of DNA, suggest a way to further expand such calculations, and also make some estimates for glial cells exposed to radiation.Comment: 18 pag,5 fig, submitted to PR

    Prioritizing Public- Private Partnership Models for Public Hospitals of Iran Based on Performance Indicators

    Get PDF
    Background: The present study was conducted to scrutinize Public- Private Partnership (PPP) models in public hospitals of different countries based on performance indicators in order to se-lect appropriated models for Iran hospitals.Methods: In this mixed (quantitative-qualitative) study, systematic review and expert panel hasbeen done to identify varied models of PPP as well as performance indicators. In the second stepwe prioritized performance indicator and PPP models based on selected performance indicatorsby Analytical Hierarchy process (AHP) technique. The data were analyzed by Excel 2007 andExpert Choice11 software’s.Results: In quality – effectiveness area, indicators like the rate of hospital infections(100%), hospital accidents prevalence rate (73%), pure rate of hospital mortality (63%), patientsatisfaction percentage (53%), in accessibility equity area indicators such as average inpatientwaiting time (100%) and average outpatient waiting time (74%), and in financial – efficiency area,indicators including average length of stay (100%), bed occupation ratio (99%), specific incometo total cost ratio (97%) have been chosen to be the most key performance indicators. In the prioritizationof the PPP models clinical outsourcing, management, privatization, BOO (build, own,operate) and non-clinical outsourcing models, achieved high priority for various performance indicatorareas.Conclusion: This study had been provided the most common PPP options in the field of public hospitals and had gathered suitable evidences from experts for choosing appropriate PPP option for public hospitals. Effect of private sector presence in public hospital performance, based on which PPP options undertaken, will be different

    X-irradiation of cells on glass slides has a dose doubling impact

    Get PDF
    Immunofluorescence detection of γH2AX foci is a widely used tool to quantify the induction and repair of DNA double-strand breaks (DSBs) induced by ionising radiation. We observed that X-irradiation of mammalian cells exposed on glass slides induced twofold higher foci numbers compared to irradiation with γ-rays. Here, we show that the excess γH2AX foci after X-irradiation are produced from secondary radiation particles generated from the irradiation of glass slides. Both 120 kV X-rays and 137Cs γ-rays induce ∼20 γH2AX foci per Gy in cells growing on thin (∼2 μm) plastic foils immersed in water. The same yield is obtained following γ-irradiation of cells growing on glass slides. However, 120 kV X-rays produce ∼40 γH2AX foci per Gy in cells growing on glass, twofold greater than obtained using cells irradiated on plastic surfaces. The same increase in γH2AX foci number is obtained if the plastic foil on which the cells are grown is irradiated on a glass slide. Thus, the physical proximity to the glass material and not morphological differences of cells growing on different surfaces accounts for the excess γH2AX foci. The increase in foci number depends on the energy and is considerably smaller for 25 kV relative to 120 kV X-rays, a finding which can be explained by known physical properties of radiation. The kinetics for the loss of foci, which is taken to represent the rate of DSB repair, as well as the Artemis dependent repair fraction, was similar following X- or γ-irradiation, demonstrating that DSBs induced by this range of treatments are repaired in an identical manner

    Mapping the Sensitive Volume of an Ion-Counting Nanodosimeter

    Full text link
    We present two methods of independently mapping the dimensions of the sensitive volume in an ion-counting nanodosimeter. The first method is based on a calculational approach simulating the extraction of ions from the sensitive volume, and the second method on probing the sensitive volume with 250 MeV protons. Sensitive-volume maps obtained with both methods are compared and systematic errors inherent in both methods are quantified.Comment: 27 pages, 8 figures. Submitted to JINST, Jan. 16 200

    Comparison of Integrated Radiation Transport Models with TEPC Measurements for the Average Quality Factors in Spaceflights

    Get PDF
    The purpose of this work is to test our theoretical model for the interpretation of radiation data measured in space. During the space missions astronauts are exposed to the complex field of radiation type and kinetic energies from galactic cosmic rays (GCR), trapped protons, and sometimes solar particle events (SPEs). The tissue equivalent proportional counter (TEPC) is a simple time-dependent approach for radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to Microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Q(sub ave)(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Q(sub ave)(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y, deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. Monte Carlo track structure simulation was employed to obtain the response of a TEPC irradiated with charged particle for an equivalent site diameter of 1 micron of wall-less counter. The calculated data of the energy absorption in the wall-less counter were compiled for various y values for several ion types at various discrete projectile energy levels. For the simulation of TEPC response from the mixed radiation environments inside a spacecraft, such as, Space Shuttle and International Space Station, the complete microdosimetric TEPC response, f( y, E, Z), were calculated with the Monte Carlo theoretical results by using the first order Lagrangian interpolation for a monovariate function at a given y value (y = 0.1 keV/micron 5000 keV/micron) at any projectile energy level (E = 0.01 MeV/u to 50,000 MeV/u) of each specific radiation type (Z = 1 to 28). Because the anomalous response has been observed at large event sizes in the experiment due to the escape of energy out of sensitive volume by delta-rays and the entry of delta-rays from the high-density wall into the low-density gas-volume cavity, Monte Carlo simulation was also made for the response of a walled-TEPC with wall thickness 2 mm and density 1 g/cm(exp 3). The radius of cavity was set to 6.35 mm and a gas density 7.874 x 10(exp -5) g/cm(exp 3). The response of the walled- and the wall-less counters were compared. The average quality factor Q(sub ave)(y) for trapped protons on STS-89 demonstrated the good agreement between the model calculations and flight TEPC data as shown. Using an integrated space radiation model (this includes the transport codes HZETRN and BRYNTRN, the quantum nuclear interaction model QMSFRG) and the resultant response distribution functions of walled-TEPC from Monte-Carlo track simulations, we compared model calculations with walled-TEPC measurements from NASA missions in LEO and made predictions for the lunar and the Mars missions. The Q(sub ave)(y) values for the trapped or the solar protons ranged from 1.9-2.5. This over-estimates the Qave(LET) values which ranged from 1.4-1.6. Both quantities increase with shield thickness due to nuclear fragmentation. The Q(sub ave)(LET) for the complete GCR spectra was found to be 3.5-4.5, while flight TEPCs measured 2.9-3.4 for Q(sub ave)(y). The GCR values are decreasing with the shield thickness. Our analysis for a proper interpretation of data supports the use of TEPCs for monitoring space radiation environment

    Electron Emission from Foils and Biological Materials after Proton Impact

    Get PDF
    Electron emission spectra from thin metal foils with thin layers of water frozen on them (amorphous solid water) after fast proton impact have been measured and have been simulated in liquid water using the event-by-event track structure code PARTRAC. The electron transport model of PARTRAC has been extended to simulate electron transport down to 1 eV by including low-energy phonon, vibrational and electronic excitations as measured by Michaud et al. (Radiat. Res. 159, 3–22, 2003) for amorphous ice. Simulated liquid water yields follow in general the amorphous solid water measurements at higher energies, but overestimate them significantly at energies below 50 eV. Originally published Radiation Physics and Chemistry, Vol. 77, No. 10-12, Oct-Dec 200

    Interpretation of TEPC Measurements in Space Flights for Radiation Monitoring

    Get PDF
    For the proper interpretation of radiation data measured in space, the results of integrated radiation transport models were compared with the tissue equivalent proportional counter (TEPC) measurements. TEPC is a simple, time-dependent approach to radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Qave(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Qave(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. The deviation of y from LET is caused by energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. The response distribution functions of the wall-less and walled TEPCs were calculated from Monte-Carlo track simulations. Using an integrated space radiation model (which includes the transport codes HZETRN and BRYNTRN, and the quantum nuclear interaction model QMSFRG) and the resultant response distribution functions from Monte-Carlo track simulations, we compared model calculations with the walled-TEPC measurements from NASA missions in LEO and made predictions for the lunar and the Mars missions. Good agreement was found for Qave(y) between the model and measured spectra from past NASA missions. The Qave(y) values for the trapped or the solar protons ranged from 1.9-2.5. This over-estimates the Qave(LET) values which ranged from 1.4-1.6. Both quantities increase with shield thickness due to nuclear fragmentation. The Qave(LET) for the complete GCR spectra was found to be 3.5-4.5, while flight TEPCs measured 2.9-3.4 for Qave(y). The GCR values are decreasing with the shield thickness. Our analysis of the measurements of TEPCs can be used for a proper interpretation of observed data of monitoring the space radiation environment

    Dynamic modelling and real-time monitoring of intelligent wells

    Get PDF
    Intelligent Wells (I-Wells) are the wells equipped with in-well Flow Control Devices (FCDs) and sensors. I-Wells offer a wide range of flow control and monitoring options, with the latter often being subject to how well the information is derived from the measured, raw data. Pressure or temperature are the measurements most commonly taken and requiring interpretation in I-Wells. This work develops innovative methods for modelling and monitoring of dynamic, transient flow in I-Wells. The topics cover: i. I-well clean-up modelling and analysis; ii. Integrated Pressure and Temperature Transient Analysis (PTTA) in wells; and iii. Pressure Transient Analysis (PTA) in I-Wells. This study starts with addressing the challenging clean-up process in I-Wells. A dynamic, coupled wellbore-reservoir modeling workflow is developed that simulates the whole process from fluid invasion to the flow back period. This is followed by investigating the role of different types of FCDs, e.g. autonomous and passive FCDs, well geometries etc. on the cleanup efficiency. General recommendations to facilitate the clean-up in I-Wells are further provided. This study continues with a novel methodology integrating mature PTA solutions with the relatively new Temperature Transient Analysis (TTA) ones for various applications such as reservoir characterization, flow rate allocation and completion monitoring. Several available TTA solutions are extended to describe the multiphase flow in the reservoir. The required modifications and workflow are developed and verified using synthetic case studies. The value of the integrated analysis is then demonstrated by presenting a new method applicable for multi-phase production rate allocation in multi-zone, vertical I-Wells. The variable rate problem in the TTA context is later studied where the distorted signal is reconstructed by proposing normalization methods and developing a data-driven deconvolution algorithm. Finally, the effect of non-linear pressure drop across FCDs in I-Wells on applicability of the classical PTA solutions is investigated. The corrections to incorporate this effect into the classical PTA solutions is implemented as well as a workflow to decompose the total skin is presented. The value and applicability of the proposed workflow are later illustrated using real field case studies. This thesis is an important contribution into the understanding, modelling, monitoring and analysis of dynamic flow process in advanced wells

    Electron scattering from molecules and molecular aggregates of biological relevance

    Get PDF
    In this Topical Review we survey the current state of the art in the study of low energy electron collisions with biologically relevant molecules and molecular clusters. We briefly describe the methods and techniques used in the investigation of these processes and summarise the results obtained so far for DNA constituents and their model compounds, amino acids, peptides and other biomolecules. The applications of the data obtained is briefly described as well as future required developments
    corecore