847 research outputs found

    Self-reported vs. objectively assessed adherence to inhaled corticosteroids in asthma

    Get PDF
    BACKGROUND: Adherence to inhaled corticosteroids (ICS) in asthma is vital for disease control. However, obtaining reliable and clinically useful measures of adherence remains a major challenge. We investigated the association between patient-reported adherence and objectively measured adherence based on filled prescriptions with inhaled corticosteroids in adults with asthma. METHODS: In total, 178 patients with asthma were asked to self-assess adherence during routine visits at a respiratory outpatient clinic. Self-assessment was performed using Foster score (“How many days in a 7-day week do you take your medication as prescribed?”, with the answer divided by 7). Objective adherence was calculated as medication possession ratio (MPR). Bivariate and multivariable linear regression, adjusted for age, sex, FEV(1), GINA treatment step, excessive use of SABA, and history of exacerbations were used for analyses. RESULTS: Of the included patients, 87.6% reported a Foster score of 100%, while the mean ICS MPR was 54.0% (SD 25%). Complex regimens such as twice-daily dosing or dual inhaler-use were associated with lower adherence (p = 0.015 and p < 0.001, respectively). Foster score was predictive of ICS MPR, with an absolute 32% increase in MPR between patients reporting Foster scores of 0 and 100% (95% CI 13–50%, p < 0.001). Female sex predicted higher ICS MPR (p = 0.019). Previous asthma-related hospitalization(s) predicted lower ICS MPR (p = 0.039). CONCLUSION: Although a weak association was found between Foster score and ICS MPR, findings do not support the use of Foster score, and by that self-reported adherence, as a reliable marker of controller adherence in asthma due to significant mismatch between patient-reported adherence and MPR. Future studies should address the complex interplay between patient-reported and objectively assessed adherence to controller medication in asthma. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40733-021-00072-2

    The inter- and intrarater reliability and agreement for field-based assessment of scapular control, shoulder range of motion, and shoulder isometric strength in elite adolescent athletes

    Get PDF
    Objectives To investigate the intra- and interrater reliability and agreement for field-based assessment of scapular control, shoulder range of motion (ROM), and shoulder isometric strength in elite youth athletes. Design Test-retest reliability and agreement study. Setting Eight blinded raters (two for each assessment) assessed players on field during two testing sessions separated by one week. Participants 162 elite youth handball players with or without a history of previous shoulder pain within the preceding six months. Main outcome measures Kappa (κ) and prevalence-adjusted bias-adjusted kappa (PABAK) coefficients for scapular control reliability, and 95% limits of agreement (LOA) for ROM and strength agreement. Results Scapular control demonstrated substantial to almost perfect reliability (κ 0.67 to 0.84, PABAK from 0.68 to 0.88). Mean strength values ranged from 0.9 N/kg to 1.6 N/kg, and LOAs ranged from −0.7 N/kg to 0.8 N/kg. Rotational strength revealed additionally systematic bias between and within rater. No or acceptable systematic bias were evident for ROM and abduction strength measures. Mean values and LOAs for ROM ranged between 39.9° to 52.3°, and from −12.6° to 9.9°, respectively. Conclusions Scapular control and ROM can be assessed on the field with acceptable reliability. The threshold for reliable measurements of isometric strength using handheld-dynamometers is high
    corecore