7 research outputs found

    Infectious Complications of Ventricular Assist Device Use in Children in the US: Data from the Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs)

    Get PDF
    Background Infections are frequent in pediatric ventricular assist device (VAD) patients. In this study we aimed to describe infections in durable VAD patients reported to Pedimacs. Methods Durable VAD data from the Pedimacs registry (September 19, 2012 to December 31, 2015) were analyzed. Infections were described with standard descriptive statistics, Kaplan–Meier analysis and competing outcomes analysis. Results There were 248 implants in 222 patients, with a mean age and a median follow-up of 11 ± 6.4 years and 2.4 patient-months (<1 day to 2.6 years), respectively. Device types were pulsatile flow (PF) in 91 (41%) patients and continuous flow (CF) in 131 (59%) patients. PF patients were younger (4 ± 4 vs 14 ± 4 years; p < 0.0001) and were more likely to have congenital heart disease (25% vs 12%; p = 0.03), prior surgery (53% vs 26%; p < 0.0001) and prior extracorporeal membrane oxygenation (24% vs 7%; p = 0.0003). Infection accounted for 17% (96 of 564) of the reported adverse events (AEs). A non-device infection was most common (51%), followed by sepsis (24%), external pump component infection (20%) and internal pump component infection (5%). Most infections were bacterial (73%) and required intravenous therapy only (77%). The risk of infection in the constant phase was higher in patients with a history of prior infection and in patients with a history of a non-infectious major AEs. Survival was lower after infection only in CF patients (p = 0.008). Conclusions Infection was the most common AE after pediatric VAD implantation. Non-device infections were most common. The best predictor of a future infection was a past infection. CF patients have higher risk of death after an infection

    Improving study conduct and data quality in clinical trials of chronic pain treatments: IMMPACT recommendations.

    No full text
    The estimated probability of progressing from phase 3 analgesic clinical trials to regulatory approval is approximately 57%, suggesting that a considerable number of treatments with phase 2 trial results deemed sufficiently successful to progress to phase 3 do not yield positive phase 3 results. Deficiencies in the quality of clinical trial conduct could account for some of this failure. An Initiative on Methods, Measurement, and Pain Assessment in Clinical Trials (IMMPACT) meeting was convened to identify potential areas for improvement in trial conduct in order to improve assay sensitivity (i.e., ability of trials to detect a true treatment effect). We present recommendations based on presentations and discussions at the meeting, literature reviews, and iterative revisions of this article. The recommendations relate to the following areas: (1) study design (i.e., to promote feasibility), (2) site selection and staff training, (3) participant selection and training, (4) treatment adherence, (5) data collection, and (8) data and study monitoring. Implementation of these recommendations may improve the quality of clinical trial data and thus the validity and assay sensitivity of clinical trials. Future research regarding the effects of these strategies will help identify the most efficient use of resources for conducting high quality clinical trials
    corecore