116 research outputs found
The Evolution of Compact Binary Star Systems
We review the formation and evolution of compact binary stars consisting of
white dwarfs (WDs), neutron stars (NSs), and black holes (BHs). Binary NSs and
BHs are thought to be the primary astrophysical sources of gravitational waves
(GWs) within the frequency band of ground-based detectors, while compact
binaries of WDs are important sources of GWs at lower frequencies to be covered
by space interferometers (LISA). Major uncertainties in the current
understanding of properties of NSs and BHs most relevant to the GW studies are
discussed, including the treatment of the natal kicks which compact stellar
remnants acquire during the core collapse of massive stars and the common
envelope phase of binary evolution. We discuss the coalescence rates of binary
NSs and BHs and prospects for their detections, the formation and evolution of
binary WDs and their observational manifestations. Special attention is given
to AM CVn-stars -- compact binaries in which the Roche lobe is filled by
another WD or a low-mass partially degenerate helium-star, as these stars are
thought to be the best LISA verification binary GW sources.Comment: 105 pages, 18 figure
A comparison of Power Doppler with conventional sonographic imaging for the evaluation of renal artery stenosis
BACKGROUND: Power Doppler (PD) has improved diagnostic capabilities of vascular sonography, mainly because it is independent from the angle of insonation. We evaluated this technique in a prospective comparison with conventional imaging, consisting in Duplex and Color Doppler, for the evaluation of Renal Artery (RA) stenosis. METHODS: Sensitivity, specificity and predictive values of PD and conventional imaging were assessed in a blinded fashion on eighteen patients, 9 with angiographic evidence of unilateral RA stenosis (hypertensive patients) and 9 with angiographically normal arteries (control group). PD images were interpreted with an angiography-like criteria. RESULTS: In the control group both techniques allowed correct visualization of 16 out of the 18 normal arteries (93% specificity). Only in five hypertensive patients RA stenosis was correctly identified with conventional technique (56% sensitivity and 86% negative predictive value); PD was successful in all hypertensive patients (100% sensitivity and negative predictive value), since the operators could obtain in each case of RA stenosis a sharp color signal of the whole vessel with a clear "minus" at the point of narrowing of the lumen. All results were statistically significant (p < 0.01). CONCLUSIONS: This study demonstrates that PD is superior to conventional imaging, in terms of sensitivity and specificity, for the diagnosis of RA stenosis, because it allows a clear visualization of the whole stenotic vascular lumen. Especially if it is used in concert with the other sonographic techniques, PD can enable a more accurate imaging of renovascular disease with results that seem comparable to selective angiography
Diagnostic role of new Doppler index in assessment of renal artery stenosis
BACKGROUND: Renal artery stenosis (RAS) is one of the main causes of secondary systemic arterial hypertension. Several non-invasive diagnostic methods for RAS have been used in hypertensive patients, such as color Doppler ultrasound (US). The aim of this study was to assess the sensitivity and specificity of a new renal Doppler US direct-method parameter: the renal-renal ratio (RRR), and compare with the sensitivity and specificity of direct-method conventional parameters: renal peak systolic velocity (RPSV) and renal aortic ratio (RAR), for the diagnosis of severe RAS. METHODS: Our study group included 34 patients with severe arterial hypertension (21 males and 13 females), mean age 54 (± 8.92) years old consecutively evaluated by renal color Doppler ultrasound (US) for significant RAS diagnosis. All of them underwent digital subtraction arteriography (DSA). RAS was significant if a diameter reduction > 50% was found. The parameters measured were: RPSV, RAR and RRR. The RRR was defined as the ratio between RPSV at the proximal or mid segment of the renal artery and RPSV measured at the distal segment of the renal artery. The sensitivity and specificity cutoff for the new RRR was calculated and compared with the sensitivity and specificity of RPSV and RAR. RESULTS: The accuracy of the direct method parameters for significant RAS were: RPSV >200 cm/s with 97% sensitivity, 72% specificity, 81% positive predictive value and 95% negative predictive value; RAR >3 with 77% sensitivity, 90% specificity, 90% positive predictive value and 76% negative predictive value. The optimal sensitivity and specificity cutoff for the new RRR was >2.7 with 97% sensitivity (p < 0.004) and 96% specificity (p < 0.02), with 97% positive predictive value and 97% negative predictive value. CONCLUSION: The new RRR has improved specificity compared with the direct method conventional parameters (RPSV >200cm/s and RAR >3). Both RRR and RPSV show better sensitivity than RAR for the RAS diagnosis
Dynamic Contrast-Enhanced MRI Assessment of Hyperemic Fractional Microvascular Blood Plasma Volume in Peripheral Arterial Disease: Initial Findings
OBJECTIVES: The aim of the current study was to describe a method that assesses the hyperemic microvascular blood plasma volume of the calf musculature. The reversibly albumin binding contrast agent gadofosveset was used in dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) to assess the microvascular status in patients with peripheral arterial disease (PAD) and healthy controls. In addition, the reproducibility of this method in healthy controls was determined. MATERIALS AND METHODS: Ten PAD patients with intermittent claudication and 10 healthy control subjects were included. Patients underwent contrast-enhanced MR angiography of the peripheral arteries, followed by one DCE MRI examination of the musculature of the calf. Healthy control subjects were examined twice on different days to determine normative values and the interreader and interscan reproducibility of the technique. The MRI protocol comprised dynamic imaging of contrast agent wash-in under reactive hyperemia conditions of the calf musculature. Using pharmacokinetic modeling the hyperemic fractional microvascular blood plasma volume (V(p), unit: %) of the anterior tibial, gastrocnemius and soleus muscles was calculated. RESULTS: V(p) was significantly lower for all muscle groups in PAD patients (4.3±1.6%, 5.0±3.3% and 6.1±3.6% for anterior tibial, gastrocnemius and soleus muscles, respectively) compared to healthy control subjects (9.1±2.0%, 8.9±1.9% and 9.3±2.1%). Differences in V(p) between muscle groups were not significant. The coefficient of variation of V(p) varied from 10-14% and 11-16% at interscan and interreader level, respectively. CONCLUSIONS: Using DCE MRI after contrast-enhanced MR angiography with gadofosveset enables reproducible assessment of hyperemic fractional microvascular blood plasma volume of the calf musculature. V(p) was lower in PAD patients than in healthy controls, which reflects a promising functional (hemodynamic) biomarker for the microvascular impairment of macrovascular lesions
Fluorescence-Based Methods for Detecting Caries Lesions: Systematic Review, Meta-Analysis and Sources of Heterogeneity
Background
Fluorescence-based methods have been proposed to aid caries lesion detection. Summarizing and analysing findings of studies about fluorescence-based methods could clarify their real benefits.
Objective
We aimed to perform a comprehensive systematic review and meta-analysis to evaluate the accuracy of fluorescence-based methods in detecting caries lesions.
Data Source
Two independent reviewers searched PubMed, Embase and Scopus through June 2012 to identify papers/articles published. Other sources were checked to identify non-published literature.
Study Eligibility Criteria, Participants and Diagnostic Methods
The eligibility criteria were studies that: (1) have assessed the accuracy of fluorescence-based methods of detecting caries lesions on occlusal, approximal or smooth surfaces, in both primary or permanent human teeth, in the laboratory or clinical setting; (2) have used a reference standard; and (3) have reported sufficient data relating to the sample size and the accuracy of methods.
Study Appraisal and Synthesis Methods
A diagnostic 2×2 table was extracted from included studies to calculate the pooled sensitivity, specificity and overall accuracy parameters (Diagnostic Odds Ratio and Summary Receiver-Operating curve). The analyses were performed separately for each method and different characteristics of the studies. The quality of the studies and heterogeneity were also evaluated.
Results
Seventy five studies met the inclusion criteria from the 434 articles initially identified. The search of the grey or non-published literature did not identify any further studies. In general, the analysis demonstrated that the fluorescence-based method tend to have similar accuracy for all types of teeth, dental surfaces or settings. There was a trend of better performance of fluorescence methods in detecting more advanced caries lesions. We also observed moderate to high heterogeneity and evidenced publication bias.
Conclusions
Fluorescence-based devices have similar overall performance; however, better accuracy in detecting more advanced caries lesions has been observed
Observational Constraints on the Common Envelope Phase
The common envelope phase was first proposed more than forty years ago to
explain the origins of evolved, close binaries like cataclysmic variables. It
is now believed that the phase plays a critical role in the formation of a wide
variety of other phenomena ranging from type Ia supernovae through to binary
black holes, while common envelope mergers are likely responsible for a range
of enigmatic transients and supernova imposters. Yet, despite its clear
importance, the common envelope phase is still rather poorly understood. Here,
we outline some of the basic principles involved, the remaining questions as
well as some of the recent observational hints from common envelope phenomena -
namely planetary nebulae and luminous red novae - which may lead to answering
these open questions.Comment: 29 pages, 8 figures. To appear in the book "Reviews in Frontiers of
Modern Astrophysics: From Space Debris to Cosmology" (eds. Kabath, Jones and
Skarka; publisher Springer Nature) funded by the European Union Erasmus+
Strategic Partnership grant "Per Aspera Ad Astra Simul"
2017-1-CZ01-KA203-03556
Mutations with epigenetic effects in myeloproliferative neoplasms and recent progress in treatment: Proceedings from the 5th International Post-ASH Symposium
Immediately following the 2010 annual American Society of Hematology (ASH) meeting, the 5th International Post-ASH Symposium on Chronic Myelogenous Leukemia and BCR-ABL1-Negative Myeloproliferative Neoplasms (MPNs) took place on 7–8 December 2010 in Orlando, Florida, USA. During this meeting, the most recent advances in laboratory research and clinical practice, including those that were presented at the 2010 ASH meeting, were discussed among recognized authorities in the field. The current paper summarizes the proceedings of this meeting in BCR-ABL1-negative MPN. We provide a detailed overview of new mutations with putative epigenetic effects (TET oncogene family member 2 (TET2), additional sex comb-like 1 (ASXL1), isocitrate dehydrogenase (IDH) and enhancer of zeste homolog 2 (EZH2)) and an update on treatment with Janus kinase (JAK) inhibitors, pomalidomide, everolimus, interferon-α, midostaurin and cladribine. In addition, the new ‘Dynamic International Prognostic Scoring System (DIPSS)-plus' prognostic model for primary myelofibrosis (PMF) and the clinical relevance of distinguishing essential thrombocythemia from prefibrotic PMF are discussed
- …