24 research outputs found

    Exercise Right Heart Catheterisation in Cardiovascular Diseases: A Guide to Interpretation and Considerations in the Management of Valvular Heart Disease

    Get PDF
    The use of exercise right heart catheterisation for the assessment of cardiovascular diseases has regained attention recently. Understanding physiologic haemodynamic exercise responses is key for the identification of abnormal haemodynamic patterns. Exercise total pulmonary resistance >3 Wood units identifies a deranged haemodynamic response and when total pulmonary resistance exceeds 3 Wood units, an exercise pulmonary artery wedge pressures/cardiac output slope >2 mmHg/l/min indicates the presence of underlying exercise-induced pulmonary hypertension related to left heart disease. In the evolving field of transcatheter interventions for valvular heart disease, exercise right heart catheterisation may objectively unmask symptoms and underlying haemodynamic abnormalities. Further studies are needed on the use of the procedure to inform the selection of patients who might receive the most benefit from transcatheter interventions for valvular heart diseases

    Increased myocardial expression of angiopoietin-2 in patients undergoing urgent surgical revascularization for acute coronary syndromes

    Get PDF
    BACKGROUND: Myocardial ischemia triggers the expression of multiple angiogenic factors including vascular endothelial growth factor and its receptors. However, vascular endothelial growth factor does not act in isolation. OBJECTIVE: To identify other genes important in the angiogenic response to clinically relevant myocardial ischemia. METHODS AND RESULTS: Paired intraoperative biopsies of ischemic and nonischemic myocardium were obtained from 12 patients with acute coronary syndromes (ACS) undergoing urgent coronary artery bypass graft surgery. Real-time polymerase chain reaction demonstrated significant upregulation of angiopoietin-2 (Ang-2) in ischemic myocardium, to a greater extent than other classical angiogenic factors. Microarray gene profiling identified Ang-2 to be among the top 10 differentially upregulated genes, in addition to genes involved in inflammation, cell signalling, remodelling and apoptosis. CONCLUSIONS: The present document is the first report of microarray analysis of patients with ACS, and supports an important role for Ang-2 in the angiogenic response to severe ischemia in the human heart. Common gene expression patterns in ACS may provide opportunities for targeted pharmacological and cellular intervention

    Mechanism and Predictors of Failed Transradial Approach for Percutaneous Coronary Interventions

    Get PDF
    ObjectivesThe study aimed to determine the mechanism and predictors of procedural failure in patients undergoing percutaneous coronary intervention (PCI) from the transradial approach (TR).BackgroundTransradial approach PCI reduces vascular complications compared with a transfemoral approach (TF). However, the mechanism and predictors of TR-PCI failure have not been well-characterized.MethodsThe study population consisted of patients undergoing TR-PCI by low-to-intermediate volume operators with traditional TF guide catheters. Baseline characteristics, procedure details, and clinical outcomes were prospectively collected. Univariate and multivariate analyses were performed to determine independent predictors of TR-PCI failure.ResultsA total of 2,100 patients underwent TR-PCI and represented 38% of PCI volume. Mean age was 64 ± 12 years, and 17% were female. Vascular complications occurred in 22 (1%), and TR-PCI failure was observed in 98 (4.7%) patients. The mechanism of TR-PCI failure included inability to advance guide catheter to ascending aorta in 50 (51%), inadequate guide catheter support in 35 (36%), and unsuccessful radial artery puncture in 13 (13%) patients. The PCI was successful in 94 (96%) patients with TR-PCI failure by switching to TF. On multivariate analysis, age >75 years (odds ratio [OR]: 3.86; 95% confidence interval [CI]: 2.33 to 6.40, p = 0.0006), prior coronary artery bypass graft surgery (OR: 7.47; 95% CI: 3.45 to 16.19, p = 0.0002), and height (OR: 0.97; 95% CI: 0.95 to 0.99, p = 0.02) were independent predictors of TR-PCI failure.ConclusionsTransradial approach PCI can be performed by low-to-intermediate volume operators with standard equipment with a low failure rate. Age >75 years, prior coronary artery bypass graft surgery, and short stature are independent predictors of TR-PCI failure. Appropriate patient selection and careful risk assessment are needed to maximize benefits offered by TR-PCI

    Compassionate use of the PASCAL transcatheter mitral valve repair system for patients with severe mitral regurgitation: a multicentre, prospective, observational, first-in-man study.

    No full text
    BACKGROUND Severe mitral regurgitation is associated with impaired prognosis if left untreated. Using the devices currently available, transcatheter mitral valve repair (TMVr) remains challenging in complex anatomical situations. We report the procedural and 30-day results of the first-in-man study of the Edwards PASCAL TMVr system. METHODS In this multicentre, prospective, observational, first-in-man study, we collected data from seven tertiary care hospitals in five countries that had a compassionate use programme in which patients underwent transcatheter mitral valve repair using the Edwards PASCAL TMVr system. Eligible patients were those with symptomatic, severe functional, degenerative, or mixed mitral regurgitation deemed at high risk or inoperable. Safety and efficacy of the procedure were prospectively assessed at device implantation, discharge, and 30 days after device implantation. The key study endpoints were technical success assessed at the end of the procedure and device success 30 days after implantation using the Mitral Valve Academic Research Consortium definitions. FINDINGS Between Sept 1, 2016, and March 31, 2017, 23 patients (median age 75 years [IQR 61-82]) had treatment for moderate-to-severe (grade 3+) or severe (grade 4+) mitral regurgitation using the Edwards PASCAL TMVr system. At baseline, the median EuroScore II score was 7·1% (IQR 3·6-12·8) and the median Society of Thoracic Surgeons predicted risk of mortality for mitral valve repair was 4·8% (2·1-9·0) and 6·8% (2·9-10·1) for mitral valve replacement. 22 (96%) of 23 patients were New York Heart Association (NYHA) class III or IV at baseline. The implantation of at least one device was successful in all patients, resulting in procedural residual mitral regurgitation of grade 2+ or less in 22 (96%) patients. Six (26%) of 23 patients had two implants. Periprocedural complications occurred in two (9%) of 23 patients (one minor bleeding event and one transient ischaemic attack). Despite the anatomical complexity of mitral regurgitation in the patients in this compassionate use cohort, technical success was achieved in 22 (96%) of 23 patients, and device success at 30 days was achieved in 18 (78%) patients. Three patients (13%) died during the 30 day follow-up. 19 (95%) of 20 patients alive 30 days after implantation were NYHA class I or II. INTERPRETATION This study establishes feasibility of the Edwards PASCAL TMVr system with a high rate of technical success and reduction of mitral regurgitation severity. Further research is needed on procedural and long-term clinical outcomes. FUNDING None

    Transcatheter Valve Repair for Patients With Mitral Regurgitation: 30-Day Results of the CLASP Study

    No full text
    OBJECTIVES: The authors report the procedural and 30-day results of the PASCAL Transcatheter Valve Repair System (Edwards Lifesciences, Irvine, California) in patients with mitral regurgitation (MR) enrolled in the multicenter, prospective, single-arm CLASP study. BACKGROUND: Severe MR may lead to symptoms, impaired quality of life, and reduced functional capacity when untreated. METHODS: Eligible patients had grade 3+ or 4+ MR despite optimal medical therapy and were deemed appropriate for the study by the local heart team. All outcomes were assessed through 30 days post-procedure. Major adverse events (MAEs) were adjudicated by an independent clinical events committee, and echocardiographic images were assessed by a core laboratory. The primary safety endpoint was the rate of MAEs at 30 days. RESULTS: Between June 2017 and September 2018, 62 patients with grade 3+ or 4+ MR were enrolled. The mean age was 76.5 years, and 51.6% of patients were in New York Heart Association functional class III or IV, with 56% functional, 36% degenerative, and 8% mixed MR etiology. At 30 days, the MAE rate was 6.5%, with an all-cause mortality rate of 1.6% and no occurrence of stroke; 98% had MR grade ≤2+, with 86% with MR grade ≤1+ (p \u3c 0.0001); and 85% were in New York Heart Association functional class I or II (p \u3c 0.0001). Six-minute walk distance improved by 36 m (p = 0.0018), and Kansas City Cardiomyopathy Questionnaire and EQ-5D scores improved by 17 (p \u3c 0.0001) and 10 (p = 0.0004) points, respectively. CONCLUSIONS: The PASCAL repair system showed feasibility and acceptable safety in the treatment of patients with grade 3+ or 4+ MR. MR severity, irrespective of etiology, was significantly reduced and accompanied by clinically and statistically significant improvements in functional status, exercise capacity, and quality of life. (The CLASP Study Edwards PASCAL Transcatheter Mitral Valve Repair System Study; NCT03170349)
    corecore