178 research outputs found

    Transport and Spectroscopic Studies of the Effects of Fullerene Structure on the Efficiency and Lifetime of Polythiophene-based Solar Cells

    Get PDF
    Time-dependent measurements of both power conversion efficiency and ultraviolet-visible absorption spectroscopy have been observed for solar cell blends containing the polymer poly(3-hexylthiophene-2,5-diyl) (P3HT) with two different functionalized C60 electron acceptor molecules: commercially available [6,6]-phenyl C61 butyric acid methyl ester (PCBM) or [6,6]-phenyl C61 butyric acid octadecyl ester (PCBOD) produced in this laboratory. Efficiency was found to decay with an exponential time dependence, while spectroscopic features show saturating exponential behavior. Time constants extracted from both types of measurements showed reasonable agreement for samples produced from the same blend. In comparison to the PCBM samples, the stability of the PCBOD blends was significantly enhanced, while both absorption and power conversion efficiency were decreased.Comment: manuscript submitted to Solar Energy Materials and Solar Cell

    Burnout among surgeons before and during the SARS-CoV-2 pandemic: an international survey

    Get PDF
    Background: SARS-CoV-2 pandemic has had many significant impacts within the surgical realm, and surgeons have been obligated to reconsider almost every aspect of daily clinical practice. Methods: This is a cross-sectional study reported in compliance with the CHERRIES guidelines and conducted through an online platform from June 14th to July 15th, 2020. The primary outcome was the burden of burnout during the pandemic indicated by the validated Shirom-Melamed Burnout Measure. Results: Nine hundred fifty-four surgeons completed the survey. The median length of practice was 10 years; 78.2% included were male with a median age of 37 years old, 39.5% were consultants, 68.9% were general surgeons, and 55.7% were affiliated with an academic institution. Overall, there was a significant increase in the mean burnout score during the pandemic; longer years of practice and older age were significantly associated with less burnout. There were significant reductions in the median number of outpatient visits, operated cases, on-call hours, emergency visits, and research work, so, 48.2% of respondents felt that the training resources were insufficient. The majority (81.3%) of respondents reported that their hospitals were included in the management of COVID-19, 66.5% felt their roles had been minimized; 41% were asked to assist in non-surgical medical practices, and 37.6% of respondents were included in COVID-19 management. Conclusions: There was a significant burnout among trainees. Almost all aspects of clinical and research activities were affected with a significant reduction in the volume of research, outpatient clinic visits, surgical procedures, on-call hours, and emergency cases hindering the training. Trial registration: The study was registered on clicaltrials.gov "NCT04433286" on 16/06/2020

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    Imbalanced fMRI Classification: An Ensemble Approach

    No full text
    Functional Magnetic Resonance Imaging (fMRI) has recently come to dominate the brain mapping field due to its reliable, noninvasive ability to gather massive amounts of data about task-specific brain activity. The high-dimensional, often noisy datasets recorded by these studies, however, pose significant statistical challenges that must be overcome before the data is ready for neurological interpretation. One such challenge is that of imbalanced data, where instances of one class far outnumber the other, which makes accurate classification very difficult by traditional methods. This thesis studies a series of imbalanced datasets from the AlzheimerÂżs Disease Neuroimaging Initiative (ADNI) and develops a new three-phase ensemble model that combines majority class undersampling through unsupervised K-Medoids clustering, an iterative l2_{2} logistic loss algorithm for feature selection, and a divide and conquer classification strategy to produce reliably stronger performance than the fieldÂżs current frontrunners

    A framework for smartphone-enabled, patient-generated health data analysis

    No full text
    Background: Digital medicine and smartphone-enabled health technologies provide a novel source of human health and human biology data. However, in part due to its intricacies, few methods have been established to analyze and interpret data in this domain. We previously conducted a six-month interventional trial examining the efficacy of a comprehensive smartphone-based health monitoring program for individuals with chronic disease. This included 38 individuals with hypertension who recorded 6,290 blood pressure readings over the trial. Methods: In the present study, we provide a hypothesis testing framework for unstructured time series data, typical of patient-generated mobile device data. We used a mixed model approach for unequally spaced repeated measures using autoregressive and generalized autoregressive models, and applied this to the blood pressure data generated in this trial. Results: We were able to detect, roughly, a 2 mmHg decrease in both systolic and diastolic blood pressure over the course of the trial despite considerable intra- and inter-individual variation. Furthermore, by supplementing this finding by using a sequential analysis approach, we observed this result over three months prior to the official study end—highlighting the effectiveness of leveraging the digital nature of this data source to form timely conclusions. Conclusions: Health data generated through the use of smartphones and other mobile devices allow individuals the opportunity to make informed health decisions, and provide researchers the opportunity to address innovative health and biology questions. The hypothesis testing framework we present can be applied in future studies utilizing digital medicine technology or implemented in the technology itself to support the quantified self

    A Rapid Method for Determination of Serum Methotrexate Using Ultra-High-Performance Liquid Chromatography–Tandem Mass Spectrometry and Its Application in Therapeutic Drug Monitoring

    No full text
    Objectives Methotrexate (MTX) has anticancer therapeutic potential with multiple doses-related adverse effects and toxicities. Immunoassays for therapeutic monitoring of serum MTX have their own limitations. Liquid chromatography–tandem mass spectrometry (LC-MS/MS) is considered as the reference method; however, commercially availability of them is limited. We aimed to adapt/develop an in-house LC-MS/MS method for therapeutic monitoring of serum MTX. Materials and Methods Serum protein precipitation was performed using acetonitrile–water containing 250 ÎŒM solution of aminoacetophenone as internal standard (IS). Chromatographic separation was achieved on a C18 column with mobile phase of 0.1% solution of formic acid (solvent A) and acetonitrile (solvent B) at a flow rate of 0.4 mL/min. MS was performed under positive ion mode with mass transition for MTX and IS as m/z 455.1→308.1 and 136.2→94.1, respectively. The method was validated by following Bioanalytical Method Validation Guidance for Industry, 2018 and applied on leukemia patients' samples on MTX therapy. Results The correlation coefficient of eight serially diluted calibration standards of 0.09 to 12.5 ÎŒM was >0.99 and had linearity with > 95% precision and accuracy at analytical quality control levels. The lower limit of MTX quantification achieved was 0.09 ÎŒM with good intensity and sharp peak as compared with blank sample. The total run time of the assay was 5 minutes. The serum MTX levels obtained by this method in leukemia patients exhibited clinical correlation and an excellent agreement with commercial immunoassay used in parallel. Conclusion We were able to develop a rapid, sensitive, and cost-effective LC-MS/MS method suitable for therapeutic drug monitoring of MTX in routine clinical diagnostic laboratories
    • 

    corecore