94 research outputs found

    Improving surface and defect center chemistry of fluorescent nanodiamonds for imaging purposes-a review

    Get PDF
    Diamonds are widely used for jewelry owing to their superior optical properties accounting for their fascinating beauty. Beyond the sparkle, diamond is highly investigated in materials science for its remarkable properties. Recently, fluorescent defects in diamond, particularly the negatively charged nitrogen-vacancy (NV-) center, have gained much attention: The NV- center emits stable, nonbleaching fluorescence, and thus could be utilized in biolabeling, as a light source, or as a Forster resonance energy transfer donor. Even more remarkable are its spin properties: with the fluorescence intensity of the NV- center reacting to the presence of small magnetic fields, it can be utilized as a sensor for magnetic fields as small as the field of a single electron spin. However, a reproducible defect and surface and defect chemistry are crucial to all applications. In this article we review methods for using nanodiamonds for different imaging purposes. The article covers (1) dispersion of particles, (2) surface cleaning, (3) particle size selection and reduction, (4) defect properties, and (5) functionalization and attachment to nanostructures, e.g., scanning probe microscopy tips

    Hydrogenation on palladium nanoparticles supported by graphene nanoplatelets

    Get PDF
    Pd nanoparticles (1 wt %; mean size ∼4 nm) were supported on ∼2 μm sized, but few nanometers thick, graphene nanoplatelets (GNPs) and compared to 1 wt % Pd on activated carbon or γ-alumina. Catalyst morphology, specific surface area, and Pd particle size were characterized by SEM, BET, and TEM, respectively. H2-TPD indicated that GNPs intercalated hydrogen, which may provide additional H2 supply to the Pd nanoparticles during C2H4 hydrogenation. Whereas the two types of Pd/GNPs (NaOH vs calcinated) catalysts were less active than Pd/C and Pd/Al2O3 below 40 °C, at 55 °C they were about 3–4 times more active. As for example Pd/GNPs (NaOH) and Pd/Al2O3 exhibited not too different mean Pd particle size (3.7 vs 2.5 nm, respectively), the higher activity is attributed to the additional hydrogen supply likely by the metal/support interface, as suggested by the varying C2H4 and H2 orders on the different supports. Operando XANES measurements during C2H4 hydrogenation revealed the presence of Pd hydride. The Pd hydride was more stable for Pd/GNPs (NaOH) than for Pd/C, once more pointing to a better hydrogen supply by graphene nanoplatelets

    Deutsche Bahn Schedules Train Rotations Using Hypergraph Optimization

    Get PDF
    Deutsche Bahn (DB) operates a large fleet of rolling stock (locomotives, wagons, and train sets) that must be combined into trains to perform rolling stock rotations. This train composition is a special characteristic of railway operations that distinguishes rolling stock rotation planning from the vehicle scheduling problems prevalent in other industries. DB models train compositions using hyperarcs. The resulting hypergraph models are addressed using a novel coarse-to-fine method that implements a hierarchical column generation over three levels of detail. This algorithm is the mathematical core of DB's fleet employment optimization (FEO) system for rolling stock rotation planning. FEO's impact within DB's planning departments has been revolutionary. DB has used it to support the company's procurements of its newest high-speed passenger train fleet and its intermodal cargo locomotive fleet for crossborder operations. FEO is the key to successful tendering in regional transport and to construction site management in daily operations. DB's planning departments appreciate FEO's high-quality results, ability to reoptimize (quickly), and ease of use. Both employees and customers benefit from the increased regularity of operations. DB attributes annual savings of 74 million euro, an annual reduction of 34,000 tons of CO2 emissions, and the elimination of 600 coupling operations in crossborder operations to the implementation of FEO

    Targeting Nanodiamonds to the Nucleus in Yeast Cells

    Get PDF
    Nanodiamonds are widely used for drug delivery, labelling or nanoscale sensing. For all these applications it is highly beneficial to have control over the intracellular location of the particles. For the first time, we have achieved targeting the nucleus of yeast cells. In terms of particle uptake, these cells are challenging due to their rigid cell wall. Thus, we used a spheroplasting protocol to remove the cell wall prior to uptake. To achieve nuclear targeting we used nanodiamonds, which were attached to antibodies. When using non-targeted particles, only 20% end up at the nucleus. In comparison, by using diamonds linked to antibodies, 70% of the diamond particles reach the nucleus

    Pain Interventions for people with dementia: a quasi-experimental study

    Get PDF
    Abstract Background Due to the complexity of the provision of care for people with dementia, pain assessment and management is still considered to be lacking. An optimal way to support frontline staff in providing pain assessment and management for people with dementia living in nursing homes has not yet been identified. The success of supporting interventions seems dependent on contextual factors in the nursing homes. This study, therefore, analyzes the feasibility of a nurse-led training intervention, using repeated on-site case studies, in modifying pain intensity and frequency in people with dementia. Methods Using a quasi-experimental design, we undertook a multi-center study of nurse-led training in pain management, with subsequent on-site case studies. Healthcare workers from 3 nursing homes assessed pain in 164 residents with dementia over 147 days. We used mixed-effect growth curve models with spline regression to analyze the data. Results We found that on-site case studies support frontline staff with pain management and assessment. Repeated reflection in case studies led to significantly longer pain free intervals (from 4.7 at baseline to 37.1 days at second follow-up) and decreased frequency of pain events (OR 0.54 at first follow-up and 0.43 at second follow-up). However no trends regarding pain intensity could be found. Therefore, on-site case studies may be valuable for improving pain frequency and pain-free intervals over time. Conclusion This feasibility study shows the potential of on-site support for frontline nursing home staff. On-site case studies may also affect health outcomes in people with dementia. However, the complexity of dementia care necessitates the management of a broader range of needs. Trial registration The study was retrospectively registered on the tenth of January 2017 with the German registry of clinical trials (DRKS00009726)

    Isoforms of Retinol binding protein 4 (RBP4) are increased in chronic diseases of the kidney but not of the liver

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The levels of retinol-binding protein 4 (RBP4) – the carrier protein for Vitamin A in plasma – are tightly regulated under healthy circumstances. The kidney, the main site of RBP4 catabolism, contributes to an elevation of RBP4 levels during chronic kidney disease (CKD) whereas during chronic liver disease (CLD) RBP4 levels decrease. Little is known about RBP4 isoforms including apo-RBP4, holo-RBP4 as well as RBP4 truncated at the C-terminus (RBP4-L and RBP4-LL) except that RBP4 isoforms have been reported to be increased in hemodialysis patients. Since it is not known whether CLD influence RBP4 isoforms, we investigated RBP4 levels, apo- and holo-RBP4 as well as RBP4-L and RBP4-LL in plasma of 36 patients suffering from CKD, in 55 CLD patients and in 50 control subjects. RBP4 was determined by ELISA and apo- and holo-RBP4 by native polyacrylamide gel electrophoresis (PAGE). RBP4-L and RBP4-LL were analyzed after immunoprecipitation by mass spectrometry (MALDI-TOF-MS).</p> <p>Results</p> <p>RBP4 isoforms and levels were highly increased in CKD patients compared to controls (P < 0.05) whereas in CLD patients RBP4 isoforms were not different from controls. In addition, in hepatic dysfunction RBP4 levels were decreased whereas the amount of isoforms was not affected.</p> <p>Conclusion</p> <p>The occurrence of RBP4 isoforms is not influenced by liver function but seems to be strongly related to kidney function and may therefore be important in investigating kidney function and related disorders.</p

    Tolerability of inhaled N-chlorotaurine in the pig model

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>N-chlorotaurine, a long-lived oxidant produced by human leukocytes, can be applied in human medicine as an endogenous antiseptic. Its antimicrobial activity can be enhanced by ammonium chloride. This study was designed to evaluate the tolerability of inhaled N-chlorotaurine (NCT) in the pig model.</p> <p>Methods</p> <p>Anesthetized pigs inhaled test solutions of 1% (55 mM) NCT (n = 7), 5% NCT (n = 6), or 1% NCT plus 1% ammonium chloride (NH<sub>4</sub>Cl) (n = 6), and 0.9% saline solution as a control (n = 7), respectively. Applications with 5 ml each were performed hourly within four hours. Lung function, haemodynamics, and pharmacokinetics were monitored. Bronchial lavage samples for captive bubble surfactometry and lung samples for histology and electron microscopy were removed.</p> <p>Results</p> <p>Arterial pressure of oxygen (PaO<sub>2</sub>) decreased significantly over the observation period of 4 hours in all animals. Compared to saline, 1% NCT + 1% NH<sub>4</sub>Cl led to significantly lower PaO<sub>2 </sub>values at the endpoint after 4 hours (62 ± 9.6 mmHg vs. 76 ± 9.2 mmHg, p = 0.014) with a corresponding increase in alveolo-arterial difference of oxygen partial pressure (AaDO<sub>2</sub>) (p = 0.004). Interestingly, AaDO<sub>2 </sub>was lowest with 1% NCT, even lower than with saline (p = 0.016). The increase of pulmonary artery pressure (PAP) over the observation period was smallest with 1% NCT without difference to controls (p = 0.91), and higher with 5% NCT (p = 0.02), and NCT + NH<sub>4</sub>Cl (p = 0.05).</p> <p>Histological and ultrastructural investigations revealed no differences between the test and control groups. The surfactant function remained intact. There was no systemic resorption of NCT detectable, and its local inactivation took place within 30 min. The concentration of NCT tolerated by A549 lung epithelial cells <it>in vitro </it>was similar to that known from other body cells (0.25–0.5 mM).</p> <p>Conclusion</p> <p>The endogenous antiseptic NCT was well tolerated at a concentration of 1% upon inhalation in the pig model. Addition of ammonium chloride in high concentration provokes a statistically significant impact on blood oxygenation.</p

    The interaction of fluorescent nanodiamond probes with cellular media

    Get PDF
    Fluorescent nanodiamonds (FNDs) are promising tools to image cells, bioanalytes and physical quantities such as temperature, pressure, and electric or magnetic fields with nanometer resolution. To exploit their potential for intracellular applications, the FNDs have to be brought into contact with cell culture media. The interactions between the medium and the diamonds crucially influence sensitivity as well as the ability to enter cells. The authors demonstrate that certain proteins and salts spontaneously adhere to the FNDs and may cause aggregation. This is a first investigation on the fundamental questions on how (a) FNDs interact with the medium, and (b) which proteins and salts are being attracted. A differentiation between strongly binding and weakly binding proteins is made. Not all proteins participate in the formation of FND aggregates. Surprisingly, some main components in the medium seem to play no role in aggregation. Simple strategies to prevent aggregation are discussed. These include adding the proteins, which are naturally present in the cell culture to the diamonds first and then inserting them in the full medium. Graphical abstractSchematic of the interaction of nanodiamonds with cell culture medium. Certain proteins and salts adhere to the diamond surface and lead to aggregation or to formation of a protein corona

    Evaluation of intracranial stenting in a simulated training and assessment environment for neuroendovascular procedures

    Get PDF
    PurposeGiven the inherent complexity of neurointerventional procedures and the associated risks of ionizing radiation exposure, it is crucial to prioritize ongoing training and improve safety protocols. The aim of this study is to assess a training and evaluation in-vitro environment using a vascular model of M1 stenosis, within a clinical angiography suite, without relying on animal models or X-ray radiation.Materials and methodsUsing a transparent model replicating M1 stenosis, we conducted intracranial stenting procedures with four different setups (Gateway &amp; Wingspan, Gateway &amp; Enterprise, Neurospeed &amp; Acclino, and Pharos Vitesse). A video camera was integrated with the angiography system’s monitor for real-time visualization, while a foot switch was employed to simulate live fluoroscopy. Three neuroradiologists with varying levels of expertise performed each procedure for three times. The total duration of fluoroscopy as well as the time from passing the stenosis with the wire to completion of the procedure were recorded using a dedicated software designed for this experimental setup.ResultsCompared to the Gateway &amp; Wingspan procedure, the total fluoroscopy time reduced significantly with the Gateway &amp; Enterprise, Neurospeed &amp; Acclino, and Pharos Vitesse procedures by 51.56 s, 111.33 s, and 144.89 s, respectively (p &lt; 0.001). Additionally, physicians with under 2 years and over 5 years of experience reduced FT by 62.83 s and 106.42 s, respectively, (p &lt; 0.001), compared to a novice physician. Similar trends were noted for the time of wire distal to stenosis, with significant reductions for Neurospeed &amp; Acclino and Pharos Vitesse compared to both Gateway &amp; Wingspan as well as Gateway &amp; Enterprise (all p &lt; 0.001).ConclusionProcedures requiring wire exchange maneuvers exhibited nearly twice the fluoroscopy time in comparison to balloon-mounted stenting or stent-placement via PTA balloon catheters. The more experienced neuroradiologist demonstrated significantly quicker performance in line with expectations in a real-life clinical setting, when compared to the less experienced interventionalist. This in-vitro setup allowed the evaluation of alternative technical approaches and differences in experience of operators without the use of animal models or X-ray. The setup combines advantages of simulators and silicone vessel models in a realistic working environment
    corecore