1,836 research outputs found

    The gene-reduction effect of chromosomal losses detected in gastric cancers

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The level of loss of heterozygosity (LOH) that reduces a gene dose and exerts a cell-adverse effect is known to be a parameter for the genetic staging of gastric cancers. This study investigated if the cell-adverse effect induced with the gene reduction was a rate-limiting factor for the LOH events in two distinct histologic types of gastric cancers, the diffuse- and intestinal-types.</p> <p>Methods</p> <p>The pathologic specimens obtained from 145 gastric cancer patients were examined for the level of LOH using 40 microsatellite markers on eight cancer-associated chromosomes (3p, 4p, 5q, 8p, 9p, 13q, 17p and 18q).</p> <p>Results</p> <p>Most of the cancer-associated chromosomes were found to belong to the gene-poor chromosomes and to contain a few stomach-specific genes that were highly expressed. A baseline-level LOH involving one or no chromosome was frequent in diffuse-type gastric cancers. The chromosome 17 containing a relatively high density of genes was commonly lost in intestinal-type cancers but not in diffuse-type cancers. A high-level LOH involving four or more chromosomes tended to be frequent in the gastric cancers with intestinal and mixed differentiation. Disease relapse was common for gastric cancers with high-level LOH through both the hematogenous (38%) and non-hematogenous (36%) routes, and for the baseline-level LOH cases through the non-hematogenous route (67%).</p> <p>Conclusions</p> <p>The cell-adverse effect of gene reduction is more tolerated in intestinal-type gastric cancers than in diffuse-type cancers, and the loss of high-dose genes is associated with hematogenous metastasis.</p

    Proceedings of the Second Annual Conference of the MidSouth Computational Biology and Bioinformatics Society

    Get PDF
    The MCBIOS 2004 conference brought together regional researchers and students in biology, computer science and bioinformatics on October 7th-9th 2004 to present their latest work. This editorial describes the conference itself and introduces the twelve peer-reviewed manuscripts accepted for publication in the Proceedings of the MCBIOS 2004 Conference. These manuscripts included new methods for analysis of high-throughput gene expression experiments, EST clustering, analysis of mass spectrometry data and genomic analysi

    RNA extraction from self-assembling peptide hydrogels to allow qPCR analysis of encapsulated cells

    Get PDF
    Self-assembling peptide hydrogels offer a novel 3-dimensional platform for many applications in cell culture and tissue engineering but are not compatible with current methods of RNA isolation; owing to interactions between RNA and the biomaterial. This study investigates the use of two techniques based on two different basic extraction principles: solution-based extraction and direct solid-state binding of RNA respectively, to extract RNA from cells encapsulated in four β-sheet forming self-assembling peptide hydrogels with varying net positive charge. RNA-peptide fibril interactions, rather than RNA-peptide molecular complexing, were found to interfere with the extraction process resulting in low yields. A column-based approach relying on RNA-specific binding was shown to be more suited to extracting RNA with higher purity from these peptide hydrogels owing to its reliance on strong specific RNA binding interactions which compete directly with RNA-peptide fibril interactions. In order to reduce the amount of fibrils present and improve RNA yields a broad spectrum enzyme solution—pronase—was used to partially digest the hydrogels before RNA extraction. This pre-treatment was shown to significantly increase the yield of RNA extracted, allowing downstream RT-qPCR to be performed

    Novel genetic analysis for case-control genome-wide association studies: quantification of power and genomic prediction accuracy

    Get PDF
    Genome-wide association studies (GWAS) are routinely conducted for both quantitative and binary (disease) traits. We present two analytical tools for use in the experimental design of GWAS. Firstly, we present power calculations quantifying power in a unified framework for a range of scenarios. In this context we consider the utility of quantitative scores (e.g. endophenotypes) that may be available on cases only or both cases and controls. Secondly, we consider, the accuracy of prediction of genetic risk from genome-wide SNPs and derive an expression for genomic prediction accuracy using a liability threshold model for disease traits in a case-control design. The expected values based on our derived equations for both power and prediction accuracy agree well with observed estimates from simulations

    Effect of cooling methods on dimensional accuracy and surface finish of a turned titanium part

    Get PDF
    In metal cutting, the choice of cooling method influences the deformation mechanism, which is related to the dimensional accuracy and surface finish of the parts. The deformation mechanism of titanium alloys under machining conditions is known to be very different from that of commonly used industrial materials. Therefore, the effect of cooling methods on dimensional accuracy and surface finish in machining titanium is of particular interest. This paper investigates experimentally and analytically the influence of cooling method and cutting parameters on two major dimensional accuracy characteristics of a turned titanium part—diameter error and circularity, and surface finish. Data were analyzed via three methods: traditional analysis, Pareto ANOVA, and Taguchi method. The findings indicate that the cooling method has significant effect on circularity error (contribution ratio 76.75 %), moderate effect on diameter error (contribution ratio 25.00 %), and negligible effect on surface finish (contribution ratio 0.16 %)

    Biocompatibility and Biodegradation Studies of Subconjunctival Implants in Rabbit Eyes

    Get PDF
    Sustained ocular drug delivery is difficult to achieve. Most drugs have poor penetration due to the multiple physiological barriers of the eye and are rapidly cleared if applied topically. Biodegradable subconjunctival implants with controlled drug release may circumvent these two problems. In our study, two microfilms (poly [d,l-lactide-co-glycolide] PLGA and poly[d,l-lactide-co-caprolactone] PLC were developed and evaluated for their degradation behavior in vitro and in vivo. We also evaluated the biocompatibility of both microfilms. Eighteen eyes (9 rabbits) were surgically implanted with one type of microfilm in each eye. Serial anterior-segment optical coherence tomography (AS-OCT) scans together with serial slit-lamp microscopy allowed us to measure thickness and cross-sectional area of the microfilms. In vitro studies revealed bulk degradation kinetics for both microfilms, while in vivo studies demonstrated surface erosion kinetics. Serial slit-lamp microscopy revealed no significant inflammation or vascularization in both types of implants (mean increase in vascularity grade PLGA50/50 12±0.5% vs. PLC70/30 15±0.6%; P = 0.91) over a period of 6 months. Histology, immunohistochemistry and immuno-fluorescence also revealed no significant inflammatory reaction from either of the microfilms, which confirmed that both microfilms are biocompatible. The duration of the drug delivery can be tailored by selecting the materials, which have different degradation kinetics, to suit the desired clinical therapeutic application
    corecore