1,326 research outputs found

    Measuring Accuracy of Automated Parsing and Categorization Tools and Processes in Digital Investigations

    Full text link
    This work presents a method for the measurement of the accuracy of evidential artifact extraction and categorization tasks in digital forensic investigations. Instead of focusing on the measurement of accuracy and errors in the functions of digital forensic tools, this work proposes the application of information retrieval measurement techniques that allow the incorporation of errors introduced by tools and analysis processes. This method uses a `gold standard' that is the collection of evidential objects determined by a digital investigator from suspect data with an unknown ground truth. This work proposes that the accuracy of tools and investigation processes can be evaluated compared to the derived gold standard using common precision and recall values. Two example case studies are presented showing the measurement of the accuracy of automated analysis tools as compared to an in-depth analysis by an expert. It is shown that such measurement can allow investigators to determine changes in accuracy of their processes over time, and determine if such a change is caused by their tools or knowledge.Comment: 17 pages, 2 appendices, 1 figure, 5th International Conference on Digital Forensics and Cyber Crime; Digital Forensics and Cyber Crime, pp. 147-169, 201

    Summary for Decision Makers

    Full text link

    Increased Matrix Metalloproteinase (MMPs) Levels Do Not Predict Disease Severity or Progression in Emphysema

    Get PDF
    Rationale: Though matrix metalloproteinases (MMPs) are critical in the pathogenesis of COPD, their utility as a disease biomarker remains uncertain. This study aimed to determine whether bronchoalveolar lavage (BALF) or plasma MMP measurements correlated with disease severity or functional decline in emphysema. Methods: Enzyme-linked immunosorbent assay and luminex assays measured MMP-1, -9, -12 and tissue inhibitor of matrix metalloproteinase-1 in the BALF and plasma of non-smokers, smokers with normal lung function and moderate-to-severe emphysema subjects. In the cohort of 101 emphysema subjects correlative analyses were done to determine if MMP or TIMP-1 levels were associated with key disease parameters or change in lung function over an 18-month time period. Main Results: Compared to non-smoking controls, MMP and TIMP-1 BALF levels were significantly elevated in the emphysema cohort. Though MMP-1 was elevated in both the normal smoker and emphysema groups, collagenase activity was only increased in the emphysema subjects. In contrast to BALF, plasma MMP-9 and TIMP-1 levels were actually decreased in the emphysema cohort compared to the control groups. Both in the BALF and plasma, MMP and TIMP-1 measurements in the emphysema subjects did not correlate with important disease parameters and were not predictive of subsequent functional decline. Conclusions: MMPs are altered in the BALF and plasma of emphysema; however, the changes in MMPs correlate poorly with parameters of disease intensity or progression. Though MMPs are pivotal in the pathogenesis of COPD, these findings suggest that measuring MMPs will have limited utility as a prognostic marker in this disease. © 2013 D'Armiento et al

    Controlled dosing of nicotine via an I ntranasal N icotine A erosol D elivery D evice (INADD)

    Full text link
    The present report describes an I ntranasal N icotine A erosol D elivery D evice (INADD) employing an artist's airbrush as aerosolizer and precise, electromechanical control of spray duration. It was designed for the administration of controlled doses of nicotine in a laboratory setting and has been used successfully in over 30 smokers and nonsmokers of both genders. In the present study, nicotine was administered to 12 male smokers at three different doses (0.05 mg, 1.00 mg, and 2.00 mg), and at the same dose (1 mg) on three different occasions. The low dose produced a minimal change in plasma nicotine, while the high dose produced a peak increment of around 16 ng/ml. The medium dose reliably produced a peak increment of around 8–9 ng/ml on all three occasions. Nicotine in plasma showed a sharp rise followed by a slower decline, mimicking the pattern associated with cigarette smoking. Physiological and biochemical responses showed significant dose-response relationships. Subjective reports suggested that aerosol dosing was somewhat aversive, but it is unclear whether this effect is intrinsic to the method or due to other factors. The device described in this report answers the need for a safe and easy means of controlling nicotine dose. Moreover, since nicotine administration via aerosol is novel for both smokers and non-smokers, minimizing the contributions of behavioral tolerance and habituation to the dosing vehicle, it lends itself to the comparison of the pharmacological effects of nicotine between experienced and naive subjects.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/46339/1/213_2005_Article_BF02247431.pd

    Exploiting Anopheles responses to thermal, odour and visual stimuli to improve surveillance and control of malaria

    Get PDF
    Mosquito surveillance and control are at the heart of efforts to eliminate malaria, however, there remain significant gaps in our understanding of mosquito behaviour that impede innovation. We hypothesised that a combination of human-associated stimuli could be used to attract and kill malaria vectors more successfully than individual stimuli, and at least as well as a real human. To test this in the field, we quantified Anopheles responses to olfactory, visual and thermal stimuli in Burkina Faso using a simple adhesive trap. Traps baited with human odour plus high contrast visual stimuli caught more Anopheles than traps with odour alone, showing that despite their nocturnal habit, malaria vectors make use of visual cues in host-seeking. The best performing traps, however, combined odour and visual stimuli with a thermal signature in the range equivalent to human body temperature. When tested against a human landing catch during peak mosquito abundance, this “host decoy” trap caught nearly ten times the number of Anopheles mosquitoes caught by a human collector. Exploiting the behavioural responses of mosquitoes to the entire suite of host stimuli promises to revolutionise vector surveillance and provide new paradigms in disease control

    Broad Antibody Mediated Cross-Neutralization and Preclinical Immunogenicity of New Codon-Optimized HIV-1 Clade CRF02_AG and G Primary Isolates

    Get PDF
    Creation of an effective vaccine for HIV has been an elusive goal of the scientific community for almost 30 years. Neutralizing antibodies are assumed to be pivotal to the success of a prophylactic vaccine but previous attempts to make an immunogen capable of generating neutralizing antibodies to primary “street strain” isolates have resulted in responses of very limited breadth and potency. The objective of the study was to determine the breadth and strength of neutralizing antibodies against autologous and heterologous primary isolates in a cohort of HIV-1 infected Nigerians and to characterize envelopes from subjects with particularly broad or strong immune responses for possible use as vaccine candidates in regions predominated by HIV-1 CRF02_AG and G subtypes. Envelope vectors from a panel of primary Nigerian isolates were constructed and tested with plasma/sera from the same cohort using the PhenoSense HIV neutralizing antibody assay (Monogram Biosciences Inc, USA) to assess the breadth and potency of neutralizing antibodies. The immediate goal of this study was realized by the recognition of three broadly cross-neutralizing sera: (NG2-clade CRF02_AG, NG3-clade CRF02_AG and NG9- clade G). Based on these findings, envelope gp140 sequences from NG2 and NG9, complemented with a gag sequence (Clade G) and consensus tat (CRF02_AG and G) antigens have been codon-optimized, synthesized, cloned and evaluated in BALB/c mice. The intramuscular administration of these plasmid DNA constructs, followed by two booster DNA immunizations, induced substantial specific humoral response against all constructs and strong cellular responses against the gag and tat constructs. These preclinical findings provide a framework for the design of candidate vaccine for use in regions where the HIV-1 epidemic is driven by clades CRF02_AG and G

    Telling partners about chlamydia: how acceptable are the new technologies?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Partner notification is accepted as a vital component in the control of chlamydia. However, in reality, many sexual partners of individuals diagnosed with chlamydia are never informed of their risk. The newer technologies of email and SMS have been used as a means of improving partner notification rates. This study explored the use and acceptability of different partner notification methods to help inform the development of strategies and resources to increase the number of partners notified.</p> <p>Methods</p> <p>Semi-structured telephone interviews were conducted with 40 people who were recently diagnosed with chlamydia from three sexual health centres and two general practices across three Australian jurisdictions.</p> <p>Results</p> <p>Most participants chose to contact their partners either in person (56%) or by phone (44%). Only 17% chose email or SMS. Participants viewed face-to-face as the "gold standard" in partner notification because it demonstrated caring, respect and courage. Telephone contact, while considered insensitive by some, was often valued because it was quick, convenient and less confronting. Email was often seen as less personal while SMS was generally considered the least acceptable method for telling partners. There was also concern that emails and SMS could be misunderstood, not taken seriously or shown to others. Despite these, email and SMS were seen to be appropriate and useful in some circumstances. Letters, both from the patients or from their doctor, were viewed more favourably but were seldom used.</p> <p>Conclusion</p> <p>These findings suggest that many people diagnosed with chlamydia are reluctant to use the new technologies for partner notification, except in specific circumstances, and our efforts in developing partner notification resources may best be focused on giving patients the skills and confidence for personal interaction.</p

    Priming with recombinant auxotrophic BCG expressing HIV-1 Gag, RT and Gp120 and boosting with recombinant MVA induces a robust T cell response in mice

    Get PDF
    In previous studies we have shown that a pantothenate auxotroph of Myocbacterium bovis BCG (BCGΔ panCD ) expressing HIV-1 subtype C Gag induced Gag-specific immune responses in mice and Chacma baboons after prime-boost immunization in combination with matched rMVA and VLP vaccines respectively. In this study recombinant BCG (rBCG) expressing HIV-1 subtype C reverse transcriptase and a truncated envelope were constructed using both the wild type BCG Pasteur strain as a vector and the pantothenate auxotroph. Mice were primed with rBCG expressing Gag and RT and boosted with a recombinant MVA, expressing a polyprotein of Gag, RT, Tat and Nef (SAAVI MVA-C). Priming with rBCGΔ panCD expressing Gag or RT rather than the wild type rBCG expressing Gag or RT resulted in higher frequencies of total HIV-specific CD8 + T cells and increased numbers of T cells specific to the subdominant Gag and RT epitopes. Increasing the dose of rBCG from 10 5 cfu to 10 7 cfu also led to an increase in the frequency of responses to subdominant HIV epitopes. A mix of the individual rBCGΔ panCD vaccines expressing either Gag, RT or the truncated Env primed the immune system for a boost with SAAVI MVA-C and generated five-fold higher numbers of HIV-specific IFN-γ-spot forming cells than mice primed with rBCGΔ panCD containing an empty vector control. Priming with the individual rBCGΔ panCD vaccines or the mix and boosting with SAAVI MVA-C also resulted in the generation of HIV-specific CD4 + and CD8 + T cells producing IFN-γ and TNF-α and CD4 + cells producing IL-2. The rBCG vaccines tested in this study were able to prime the immune system for a boost with rMVA expressing matching antigens, inducing robust, HIV-specific T cell responses to both dominant and subdominant epitopes in the individual proteins when used as individual vaccines or in a mix
    corecore