12,674 research outputs found

    Estimates of Optimal Operating Conditions for Hydrogen-Oxygen Cesium-Seeded Magnetohydrodynamic Power Generator

    Get PDF
    The value of percent seed, oxygen to fuel ratio, combustion pressure, Mach number, and magnetic field strength which maximize either the electrical conductivity or power density at the entrance of an MHD power generator was obtained. The working fluid is the combustion product of H2 and O2 seeded with CsOH. The ideal theoretical segmented Faraday generator along with an empirical form found from correlating the data of many experimenters working with generators of different sizes, electrode configurations, and working fluids, are investigated. The conductivity and power densities optimize at a seed fraction of 3.5 mole percent and an oxygen to hydrogen weight ratio of 7.5. The optimum values of combustion pressure and Mach number depend on the operating magnetic field strength

    Closed cycle MHD power generation experiments in the NASA Lewis Facility

    Get PDF
    Many modifications were made in the MHD facility. These include a redesign of the MHD duct interior, addition of mixing bars, increased electrical isolation of all the high temperature components from each other and from ground, and experimentation with various cesium seed vaporization and injection techniques. With the exception of the cesium system which needs further improvement the above modifications were quite successful and resulted in improvements in generator performance. The facility was run for a total of 400 hours in the past year, with 70 hours of this operation at temperatures of 2000 K or more with hot generator walls. With the exception of replacing one cracked brick in the MHD channel no repairs were required in the high temperature loop components for the duration of these tests. Uniform Faraday and Hall voltage profiles were obtained and the Faraday open circuit voltage varied from 90 to 100 percent of the ideal uBh. The magnitudes of the measured parameters are: Faraday open circuit voltage approximately 70 V, total Faraday current approximately 20 A, Hall voltage approximately 250 V, power output approximately 300 W, and power density .036 W/cu cm

    Large Area Crop Inventory Experiment (LACIE). Phase 3 direct wheat study of North Dakota

    Get PDF
    The author has identified the following significant results. The green number and brightness scatter plots, channel plots of radiance values, and visual study of the imagery indicate separability between barley and spring wheat/oats during the wheat mid-heading to mid-ripe stages. In the LACIE Phase 3 North Dakota data set, the separation time is more specifically the wheat soft dough stage. At this time, the barley is ripening, and is therefore, less green and brighter than the wheat. Only 4 of the 18 segments studied indicate separation of barley/other spring small grain, even though 11 of the segments have acquisitions covering the wheat soft dough stage. The remaining seven segments had less than 5 percent barley based on ground truth data

    H2-O2 combustion powered steam-MHD central power systems

    Get PDF
    Estimates are made for both the performance and the power costs of H2-O2 combustion powered steam-MHD central power systems. Hydrogen gas is assumed to be transmitted by pipe from a remote coal gasifier into the city and converted to electricity in a steam MHD plant having an integral gaseous oxygen plant. These steam MHD systems appear to offer an attractive alternative to both in-city clean fueled conventional steam power plants and to remote coal fired power plants with underground electric transmission into the city

    Corn/soybean decision logic: Improvements and new crops

    Get PDF
    There are no author-identified significant results in this report

    Characterization of the Torsional Piezoelectric-like Response of Tantalum Trisulfide Associated with Charge-Density-Wave Depinning

    Full text link
    We have studied the frequency and voltage dependence of voltage-induced torsional strains in orthorhombic TaS3 [V. Ya. Pokrovskii, et al, Phys. Rev. Lett. 98, 206404 (2007)] by measuring the modulation of the resonant frequency of an RF cavity containing the sample. The strain has an onset voltage below the charge-density-wave (CDW) threshold voltages associated with changes in shear compliance and resistance, suggesting that the strain is associated with polarization of the CDW rather than CDW current. Measurements with square-wave voltages show that the strain is very sluggish, not even reaching its dc value at a frequency of 0.1 Hz, but the dynamics appear to be very sample dependent. By applying oscillating torque while biasing the sample with a dc current, we have also looked for strain induced voltage in the sample; none is observed at the low biases where the voltage-induced strains first occur, but an induced voltage is observed at higher biases, probably associated with strain-dependent CDW conductance.Comment: 11 pages, including 3 figures, to be published in Phys. Rev. B (Rapid Comm.

    A Consumer Test of Citrus Drinks made from Comminuted Whole Citrus Fruit

    Get PDF
    Consumer, Citrus, Whole Citrus Fruit, Citrus Fruit, Consumer Test, Consumer/Household Economics, Food Consumption/Nutrition/Food Safety,
    • …