2,829 research outputs found

    An Analysis of Pathological Gait

    Get PDF

    Disk-Halo Model for Flat-Spectrum T Tauri Stars

    Get PDF
    We explore the origin of the flat spectrum seen in some T Tauri stars by considering a three-component structure: a central star, a circumstellar disk, and a dusty halo. The radiative energy transport is faithfully treated by solving the angle- and frequency-dependent radiative transfer equation in two space dimensions assuming axisymmetry, and hence the radiative equilibrium temperature in the disk and halo is determined simultaneously. The disk is effectively heated by the scattering and reprocessing of stellar radiation through the halo. The large mid- to far-infrared excess originates from the photosphere of the warmed disk, resulting in a flat spectrum, as observed. The halo which we consider is observed as a compact reflection nebula, and is discriminated from extended, disk-like envelopes around flat-spectrum T Tauri stars. We show that the overall spectral shape of flat-spectrum T Tauri stars can be reproduced by the present disk-halo model.Comment: 10 pages including 9 figure

    Improvement of region of interest extraction and scanning method of computer-aided diagnosis system for osteoporosis using panoramic radiographs

    Get PDF
    ObjectivesPatients undergoing osteoporosis treatment benefit greatly from early detection. We previously developed a computer-aided diagnosis (CAD) system to identify osteoporosis using panoramic radiographs. However, the region of interest (ROI) was relatively small, and the method to select suitable ROIs was labor-intensive. This study aimed to expand the ROI and perform semi-automatized extraction of ROIs. The diagnostic performance and operating time were also assessed.MethodsWe used panoramic radiographs and skeletal bone mineral density data of 200 postmenopausal women. Using the reference point that we defined by averaging 100 panoramic images as the lower mandibular border under the mental foramen, a 400x100-pixel ROI was automatically extracted and divided into four 100x100-pixel blocks. Valid blocks were analyzed using program 1, which examined each block separately, and program 2, which divided the blocks into smaller segments and performed scans/analyses across blocks. Diagnostic performance was evaluated using another set of 100 panoramic images.ResultsMost ROIs (97.0%) were correctly extracted. The operation time decreased to 51.4% for program 1 and to 69.3% for program 2. The sensitivity, specificity, and accuracy for identifying osteoporosis were 84.0, 68.0, and 72.0% for program 1 and 92.0, 62.7, and 70.0% for program 2, respectively. Compared with the previous conventional system, program 2 recorded a slightly higher sensitivity, although it occasionally also elicited false positives.ConclusionsPatients at risk for osteoporosis can be identified more rapidly using this new CAD system, which may contribute to earlier detection and intervention and improved medical care

    Effect of higher orbital angular momenta in the baryon spectrum

    Get PDF
    We have performed a Faddeev calculation of the baryon spectrum for the chiral constituent quark model including higher orbital angular momentum states. We have found that the effect of these states is important, although a description of the baryon spectrum of the same quality as the one given by including only the lowest-order configurations can be obtained. We have studied the effect of the pseudoscalar quark-quark interaction on the relative position of the positive- and negative-parity excitations of the nucleon as well as the effect of varying the strength of the color-magnetic interaction.Comment: 7 pages, 4 figures. To be published in Phys. Rev. C (November 2001

    Abnormal positioning of the common carotid artery clinically diagnosed as a submandibular mass

    Get PDF
    The common carotid artery (CCA) usually runs along the long axis of the neck, although it is occasionally found in an abnormal position or is displaced. We report a case of an 86-year-old woman in whom the CCA was identified in the submandibular area. The patient visited our clinic and reported soft tissue swelling in the right submandibular area. It resembled a tumor mass or a swollen lymph node. Computed tomography showed that it was the right CCA that had been bent forward and was running along the submandibular subcutaneous area. Ultrasonography verified the diagnosis. No other lesions were found on the diagnostic images. Consequently, the patient was diagnosed as having abnormal CCA positioning. Although this condition generally requires no treatment, it is important to follow-up the abnormality with diagnostic imaging because of the risk of cerebrovascular disorders

    Computer-aided diagnosis system for osteoporosis based on quantitative evaluation of mandibular lower border porosity using panoramic radiographs

    Get PDF
    Objectives: A new computer-aided screening system for osteoporosis using panoramic radiographs was developed. The conventional system could detect porotic changes within the lower border of the mandible, but its severity could not be evaluated. Our aim was to enable the system to measure severity by implementing a linear bone resorption severity index (BRSI) based on the cortical bone shape. Methods: The participants were 68 females (>50 years) who underwent panoramic radiography and lumbar spine bone density measurements. The new system was designed to extract the lower border of the mandible as region of interests and convert them into morphological skeleton line images. The total perimeter length of the skeleton lines was defined as the BRSI. 40 images were visually evaluated for the presence of cortical bone porosity. The correlation between visual evaluation and BRSI of the participants, and the optimal threshold value of BRSI for new system were investigated through a receiver operator characteristic analysis. The diagnostic performance of the new system was evaluated by comparing the results from new system and lumbar bone density tests using 28 participants. Results: BRSI and lumbar bone density showed a strong negative correlation (p < 0.01). BRSI showed a strong correlation with visual evaluation. The new system showed high diagnostic efficacy with sensitivity of 90.9%, specificity of 64.7%, and accuracy of 75.0%. Conclusions: The new screening system is able to quantitatively evaluate mandibular cortical porosity. This allows for preventive screening for osteoporosis thereby enhancing clinical prospects

    The effectiveness of mouthwashes in alleviating radiation-induced oral mucositis in head and neck cancer patients: A systematic review

    Get PDF
    Objective The aim of the study was to perform a systematic literature search and meta-analysis to reveal the most effective mouthwash for head and neck cancer patients who are experiencing radiation therapy-induced mucositis. Methods Using two electronic databases, a literature search and data interpretation were systematically performed as follows: (i) problem specification, (ii) devising of a literature search plan, (iii) literature search and retrieval of publications, and (iv) meta-analysis and data interpretation. The main problem was specified as follows: what mouthwash is effective in alleviating oral mucositis for head and neck cancer patients who are undergoing radiotherapy? Results The literature search yielded 354 titles and abstracts. After reviewing the extracted literature, 25 publications met the inclusion criteria for this study and 17 of 25 were eventually evaluated in the meta-analysis. Conclusion The results of the meta-analysis indicated that the use of a mouthwash that includes anti-inflammatory properties contributes the most to alleviating oral mucositis in patients who are undergoing radiotherapy to treat head and neck cancer

    On-off optical switching of the magnetic and structural properties in a spin-crossover complex

    Get PDF
    A photoexcitation is one of the promising external fields to control the material phases. Here, the authors have demonstrated that the magnetic and structural properties of a spin-crossover complex, Fe(phen)2(NCS)2 (phen=1,10-phenanthroline), can be reversibly switched by the on-off action of the continuous photoexcitation at the same temperature. The structural data suggest that the density of the high-spin Fe2+ in the photoinduced phase is about 0.88. Suppressed atomic vibrations of the photoinduced phase exclude the conventional heating effect as the origin for the observed optical switching

    Cooperative formation of high-spin species in a photoexcited spin-crossover complex

    Get PDF
    The dynamics of the photoinduced phase transition was investigated in a prototypical spin crossover complex, [Fe(ptz)6](BF4)2 (ptz=1-propyltetrazole), under photoexcitation at 77 K near the transition temperature (Tc=130 K). When the excitation power I exceeds [approximate]1 mW/mm2, we observed an "acceleration" of the creation rate of the density nHS of the high-spin (HS) species after a characteristic incubation period. The "acceleration" is interpreted in terms of the negative pressure effect; the photocreated HS species with a larger ionic radius expands the volume to cause the structural phase transition
    corecore