244 research outputs found

    On-sky results of the adaptive optics MACAO for the new IR-spectrograph CRIRES at VLT

    Get PDF
    The adaptive optics MACAO has been implemented in 6 focii of the VLT observatory, in three different flavors. We present in this paper the results obtained during the commissioning of the last of these units, MACAO-CRIRES. CRIRES is a high-resolution spectrograph, which efficiency will be improved by a factor two at least for point-sources observations with a NGS brighter than R=15. During the commissioning, Strehl exceeding 60% have been observed with fair seeing conditions, and a general description of the performance of this curvature adaptive optics system is done.Comment: SPIE conference 2006, Advances in adaptive optics, 12 pages, 11 figure

    Acoustic radiation force impulse: a new ultrasonographic technology for the widespread noninvasive diagnosis of liver fibrosis:

    Get PDF
    Background/aims: As a module of a standard ultrasound imaging device, acoustic radiation force impulse (ARFI) is a new technology for liver stiffness evaluation (LSE). We aimed to evaluate accuracy, feasibility, reproducibility, and training effect of ARFI for liver fibrosis evaluation.Methods: One hundred and one patients with chronic liver disease had LSE by Fibroscan and ARFI. LSE by ARFI was performed in the two liver lobes by two operators: an expert and a novice. Correlation and agreement were evaluated by the Pearson (Rp) and intraclass (Ric) correlation coefficients. The independent reference for liver fibrosis was fibrosis blood tests. Results: ARFI results, ranging from 0.7 to 4.6 m/s, were well correlated with Fibroscan results (Rp=0.76). Fibroscan had a significantly higher area under the receiver operating characteristic curve (AUROC) than ARFI for the perprotocol diagnosis of significant fibrosis: 0.890±0.034 versus 0.795±0.047 (P=0.04). However, LSE failure occurred in zero patients using ARFI versus six patients using Fibroscan (P=0.03). Thus, on an intention-to-diagnose basis, Fibroscan and ARFI AUROCs for the diagnosis of significant fibrosis were not different: 0.791±0.049 versus 0.793±0.046 (P=0.98). Interobserver agreement was very good (Ric=0.84) and excellent for ARFI interquartile range (IQR)≤0.30 (Ric=0.91). Indeed, agreement was independently predicted only by ARFI IQR, but not by LSE result as earlier observed for Fibroscan. ARFI AUROC was 0.876±0.057 in patients with ARFI IQR ratio≤0.30, and Fibroscan AUROC was 0.912±0.034 in patients with Fibroscan IQR ratio less than 0.21 (P=0.59). Intersite ARFI agreement between the two liver lobes was fair (Ric=0.60). There was no training effect for LSE by ARFI. Conclusion: ARFI is highly feasible and reproducible, and provides diagnostic accuracy similar to Fibroscan. This new device seems noteworthy for the widespread noninvasive diagnosis of liver fibrosis

    Evaluation of borage extracts as potential biostimulant using a phenomic, agronomic, physiological and biochemical approach

    Get PDF
    Biostimulants are substances able to improve water and nutrient use efficiency and counteract stress factors by enhancing primary and secondary metabolism. Premise of the work was to exploit raw extracts from leaves (LE) or flowers (FE) of Borago officinalis L., to enhance yield and quality of Lactuca sativa ‘Longifolia,’ and to set up a protocol to assess their effects. To this aim, an integrated study on agronomic, physiological and biochemical aspects, including also a phenomic approach, has been adopted. Extracts were diluted to 1 or 10 mL L–1, sprayed onto lettuce plants at the middle of the growing cycle and 1 day before harvest. Control plants were treated with water. Non-destructive analyses were conducted to assess the effect of extracts on biomass with an innovative imaging technique, and on leaf photosynthetic efficiency (chlorophyll a fluorescence and leaf gas exchanges). At harvest, the levels of ethylene, photosynthetic pigments, nitrate, and primary (sucrose and total sugars) and secondary (total phenols and flavonoids) metabolites, including the activity and levels of phenylalanine ammonia lyase (PAL) were assessed. Moreover, a preliminary study of the effects during postharvest was performed. Borage extracts enhanced the primary metabolism by increasing leaf pigments and photosynthetic activity. Plant fresh weight increased upon treatments with 10 mL L–1 doses, as correctly estimated by multi-view angles images. Chlorophyll a fluorescence data showed that FEs were able to increase the number of active reaction centers per cross section; a similar trend was observed for the performance index. Ethylene was three-fold lower in FEs treatments. Nitrate and sugar levels did not change in response to the different treatments. Total flavonoids and phenols, as well as the total protein levels, the in vitro PAL specific activity, and the levels of PAL-like polypeptides were increased by all borage extracts, with particular regard to FEs. FEs also proved efficient in preventing degradation and inducing an increase in photosynthetic pigments during storage. In conclusion, borage extracts, with particular regard to the flower ones, appear to indeed exert biostimulant effects on lettuce; future work will be required to further investigate on their efficacy in different conditions and/or species

    Hemodynamic and antifibrotic effects of a selective liver nitric oxide donor V-PYRRO/NO in bile duct ligated rats.

    Get PDF
    AIM: To assess whether a liver specific nitric oxide (NO) donor (V-PYRRO/NO) would prevent the development of portal hypertension and liver fibrosis in rats with bile duct ligation (BDL). METHODS: Treatment (placebo or V-PYRRO/NO 0.53 micromol/kg per hour) was administered i.v. to rats 2 d before BDL (D-2) and maintained until the day of hemodynamic measurement (D26). Intra-hepatic NO level was estimated by measuring liver cGMP level. Effects of V-PYRRO/NO on liver fibrosis and lipid peroxidation were also assessed. RESULTS: Compared to placebo treatment, V-PYRRO/NO improved splanchnic hemodynamics in BDL rats: portal pressure was significantly reduced by 27% (P<0.0001) and collateral circulation development was almost completely blocked (splenorenal shunt blood flow by 74%, P=0.007). Moreover, V-PYRRO/NO significantly prevented liver fibrosis development in BDL rats (by 30% in hepatic hydroxyproline content and 31% in the area of fibrosis, P<0.0001 respectively), this effect being probably due to a decrease in lipid peroxidation by 44% in the hepatic malondialdehyde level (P=0.007). Interestingly, we observed a significant and expected increase in liver cGMP, without any systemic hemodynamic effects (mean arterial pressure, vascular systemic resistance and cardiac output) in both sham-operated and BDL rats treated with V-PYRRO/NO. This result is in accordance with studies on V-PYRRO/NO metabolism showing a specific release of NO in the liver. CONCLUSION: Continuous administrations of V-PYRRO/NO in BDL rats improved liver fibrosis and splanchnic hemodynamics without any noxious systemic hemo-dynamic effects

    Determination of reliability criteria for liver stiffness evaluation by transient elastography

    Get PDF
    UNLABELLED: Liver stiffness evaluation (LSE) is usually considered as reliable when it fulfills all the following criteria: ≥10 valid measurements, ≥60% success rate, and interquartile range / median ratio (IQR/M) ≤0.30. However, such reliable LSE have never been shown to be more accurate than unreliable LSE. Thus, we aimed to evaluate the relevance of the usual definition for LSE reliability, and to improve reliability by using diagnostic accuracy as a primary outcome in a large population. 1,165 patients with chronic liver disease from 19 French centers were included. All patients had liver biopsy and LSE. 75.7% of LSE were reliable according to the usual definition. However, these reliable LSE were not significantly more accurate than unreliable LSE with, respectively: 85.8% versus 81.5% well-classified patients for the diagnosis of cirrhosis (P = 0.082). In multivariate analyses with different diagnostic targets, LSE median and IQR/M were independent predictors of fibrosis staging, with no significant influence of ≥10 valid measurements or LSE success rate. These two reliability criteria determined three LSE groups: "very reliable" (IQR/M ≤0.10), "reliable" (0.10< IQR/M ≤0.30, or IQR/M >0.30 with LSE median <7.1 kPa), and "poorly reliable" (IQR/M >0.30 with LSE median ≥7.1 kPa). The rates of well-classified patients for the diagnosis of cirrhosis were, respectively: 90.4%, 85.8%, and 69.5% (P < 10(-3) ). According to these new reliability criteria, 9.1% of LSE were poorly reliable (versus 24.3% unreliable LSE with the usual definition, P < 10(-3) ), 74.3% were reliable, and 16.6% were very reliable. CONCLUSION: The usual definition for LSE reliability is not relevant. LSE reliability depends on IQR/M according to liver stiffness median level, defining thus three reliability categories: very reliable, reliable, and poorly reliable LSE. (HEPATOLOGY 2013)

    The combination of a blood test and Fibroscan improves the non-invasive diagnosis of liver fibrosis

    Get PDF
    Background and aims: Blood tests and liver stiffness evaluation (LSE) by ultrasonographic elastometry are accurate tools for diagnosing liver fibrosis. We evaluated whether their synchronous combination in new scores could improve the diagnostic accuracy and reduce liver biopsy requirement in algorithm. Methods: Three hundred and ninety patients with chronic liver disease of miscellaneous causes were included. Five blood fibrosis tests were evaluated: APRI, FIB-4, Hepascore, Fibrotest and FibroMeter. The reference was fibrosis Metavir staging. Results: Diagnosis of significant fibrosis (Metavir F≥2). The most accurate synchronous combination was FibroMeter+LSE, which provided a significantly higher area under the receiver operating characteristic curve (0.892) than LSE alone (0.867, P=0.011) or Fibrometer (0.834, P<10−3). An algorithm using the FibroMeter+LSE combination and then a liver biopsy in indeterminate cases had 91.9% diagnostic accuracy and required significantly fewer biopsies (20.2%) than previously published Bordeaux algorithm (28.6%, P=0.02) or sequential algorithm for fibrosis evaluation (SAFE) (55.7%, P<10−3). The Angers algorithm performance was not significantly different between viral hepatitis and other causes. Diagnosis of cirrhosis. The most accurate synchronous combination was LSE+FibroMeter, which provided ≥90% predictive values for cirrhosis in 90.6% of patients vs 87.4% for LSE (P=0.02) and 57.9% for FibroMeter (P<10−3). An algorithm including the LSE+FibroMeter combination, and then a liver biopsy in indeterminate cases, had a significantly higher diagnostic accuracy than the SAFE algorithm (91.0 vs 79.8%, P<10−3), and required significantly fewer biopsies than the Bordeaux algorithm (9.3 vs 25.3%, P<10−3). Conclusion: The synchronous combination of a blood test plus LSE improves the accuracy of the non-invasive diagnosis of liver fibrosis and, consequently, markedly decreases the biopsy requirement in the diagnostic algorithm, notably to <10% in cirrhosis diagnosis

    Reproducibility of Liver Stiffness Measurement by Ultrasonographic Elastometry

    Get PDF
    Background & AimsFibroscan is a noninvasive device that assesses liver fibrosis by liver stiffness evaluation (LSE) with ultrasonographic elastometry. We evaluated LSE reproducibility and its influencing factors. Methods LSE was performed by 4 experienced physicians (>100 LSEs) in 46 patients with chronic liver disease at 4 different anatomic sites. Additional LSEs were performed for ancillary aims, so that 534 LSEs were available. Results Overall interobserver agreement for LSE results was considered as excellent, with intraclass coefficient correlation (Ric) of 0.93. Low LSE level, nonrecommended sites, LSE interquartile range > 25%, and body mass index ≥25 independently decreased agreement. Thus, agreement was fair (Ric = 0.53) for LSE < 9 kilopascals and excellent (Ric = 0.90) beyond. The best measurement site for LSE reproducibility was the median axillary line on the first intercostal space under the liver dullness upper limit, with the patient lying in dorsal decubitus. When LSE results were categorized into fibrosis Metavir stages, interobserver discordance was noticed in about 25% of the cases and was the highest for F2 and F3 stages and the lowest for F4. Intraobserver (Ric = 0.94), intersite (Ric = 0.92–0.98), and interequipment (Ric = 0.92) agreements for LSE results were excellent. Preliminary standard ultrasonography or probe pressure changes did not improve interobserver agreement. Conclusions The best measurement site for LSE is the one generally used for liver biopsy. Reproducibility of LSE is globally excellent but is fair in patient with low liver stiffness. The fibrosis diagnosis by ultrasonographic elastometry in low stages or categorized into fibrosis Metavir stages must be interpreted with caution

    Metastatic hepatocellular carcinoma: when surgery and successive palliative treatments lead to remission.

    Get PDF
    Hepatocellular carcinoma (HCC) is the third leading cause of death by cancer worldwide. The prognosis of patients with metastatic HCC remains limited, with an expected median survival lower than 50% at 1 year. Here, we report the case of a 63-year-old man who suffered from a small HCC in the liver and a large unique metastasis in the right adrenal gland. A surgical resection of both lesions was performed. Seven months later, HCC recurred with an isolated right renal metastatic lymphadenopathy and a high alpha-fetoprotein level. HCC was brought under control by sorafenib; the alpha-fetoprotein level was greatly reduced but remained moderately elevated and stable over 2 years after the onset of chemotherapy. Additional external radiotherapy on the metastatic lymphadenopathy led to a normalization of the alpha-fetoprotein level and discontinuation of sorafenib treatment. One year after the end of radiotherapy, a second isolated metastasis occurred in the right lung. This tumor was surgically removed. Twenty-one months after this second surgical procedure, i.e., more than 5.5 years after the initial diagnosis of metastatic HCC, the patient was asymptomatic and tumor free
    • …
    corecore